Investigation and optimisation of a multipass resonant photoacoustic cell at high absorption levels

被引:27
作者
Rey, JM [1 ]
Marinov, D [1 ]
Vogler, DE [1 ]
Sigrist, MW [1 ]
机构
[1] Swiss Fed Inst Technol, Inst Quantum Elect, Laser Spect & Sensing Lab, CH-8093 Zurich, Switzerland
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2005年 / 80卷 / 02期
关键词
D O I
10.1007/s00340-004-1705-1
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A theoretical and experimental investigation of photoacoustic (PA) signals in a resonant multipass PA cell with high background absorption (up to 29 m(-1)) is presented. An analogous electric transmission line model including discontinuity inductances at cross section changes was used to model the first longitudinal acoustic mode of the multipass PA cell equipped with two buffer volumes. This model was validated with experimentally obtained results and used to predict the behaviour of the PA cell for different multipass arrangements and different buffer volume diameters. The highest PA signal is obtained for high pass number and large buffer radius. Increasing the absorption coefficient of the medium enhances the PA signal until a maximum is reached, leading to a minimum for the PA signal sensitivity. For a given background absorption, the number of passes required to maximise the sensitivity depends on the absorption coefficient. The model allows the determination of the best-suited number of passes for a given absorption coefficient and cell geometry.
引用
收藏
页码:261 / 266
页数:6
相关论文
共 40 条
  • [1] *AIR LIQ, 1976, GAS ENC
  • [2] [Anonymous], 4032012 WST
  • [3] CO-LASER PHOTOACOUSTIC-SPECTROSCOPY OF GASES AND VAPORS FOR TRACE GAS-ANALYSIS
    BERNEGGER, S
    SIGRIST, MW
    [J]. INFRARED PHYSICS, 1990, 30 (05): : 375 - 429
  • [4] Geometrical optimization of a longitudinal resonant photoacoustic cell for sensitive and fast trace gas detection
    Bijnen, FGC
    Reuss, J
    Harren, FJM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (08) : 2914 - 2923
  • [5] TRACE GAS-DETECTION BY LASER INTRACAVITY PHOTOTHERMAL SPECTROSCOPY
    FUNG, KH
    LIN, HB
    [J]. APPLIED OPTICS, 1986, 25 (05): : 749 - 752
  • [6] BREWSTER WINDOW AND WINDOWLESS RESONANT SPECTROPHONES FOR INTRA-CAVITY OPERATION
    GERLACH, R
    AMER, NM
    [J]. APPLIED PHYSICS, 1980, 23 (03): : 319 - 326
  • [7] SENSITIVE INTRACAVITY PHOTOACOUSTIC MEASUREMENTS WITH A CO2 WAVE-GUIDE LASER
    HARREN, FJM
    BIJNEN, FGC
    REUSS, J
    VOESENEK, LACJ
    BLOM, CWPM
    [J]. APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1990, 50 (02): : 137 - 144
  • [8] On-line laser photoacoustic detection of ethene in exhaled air as biomarker of ultraviolet radiation damage of the human skin
    Harren, FJM
    Berkelmans, R
    Kuiper, K
    Hekkert, ST
    Scheepers, P
    Dekhuijzen, R
    Hollander, P
    Parker, DH
    [J]. APPLIED PHYSICS LETTERS, 1999, 74 (12) : 1761 - 1763
  • [9] HESS P, 1983, TOP CURR CHEM, V111, P1
  • [10] SENSITIVE PHOTOACOUSTIC OVERTONE SPECTROSCOPY OF ACETYLENE WITH A MULTIPASS PHOTOACOUSTIC CELL AND A COLOR-CENTER LASER AT 1.5-MU-M
    HORNBERGER, C
    KONIG, M
    RAI, SB
    DEMTRODER, W
    [J]. CHEMICAL PHYSICS, 1995, 190 (2-3) : 171 - 177