Electrodiagnostic Evaluation of Individuals Implanted With Extracellular Matrix for the Treatment of Volumetric Muscle Injury: Case Series

被引:30
作者
Han, Nami [1 ,2 ]
Yabroudi, Mohammad A. [3 ]
Stearns-Reider, Kristen [1 ,4 ]
Helkowski, Wendy [1 ]
Sicari, Brian M. [4 ,5 ]
Rubin, J. Peter [4 ,6 ,7 ]
Badylak, Stephen F. [4 ,5 ]
Boninger, Michael L. [1 ,4 ]
Ambrosio, Fabrisia [1 ,3 ,4 ,8 ]
机构
[1] Univ Pittsburgh, Dept Phys Med & Rehabil, 450 Technol Dr,Ste 308,Bridgeside Point Bldg 2, Pittsburgh, PA 15260 USA
[2] Inje Univ, Busan Paik Hosp, Dept Phys Med & Rehabil, Busan, South Korea
[3] Univ Pittsburgh, Dept Phys Therapy, Pittsburgh, PA USA
[4] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA USA
[5] Univ Pittsburgh, Dept Surg, Pittsburgh, PA USA
[6] Univ Pittsburgh, Dept Plast Surg, Pittsburgh, PA USA
[7] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[8] Univ Pittsburgh, Dept Microbiol & Mol Genet, Pittsburgh, PA USA
来源
PHYSICAL THERAPY | 2016年 / 96卷 / 04期
关键词
SMALL-INTESTINAL SUBMUCOSA; REGENERATIVE MEDICINE APPROACH; DONOR-SITE MORBIDITY; SKELETAL-MUSCLE; ELECTROMYOGRAPHIC ANALYSIS; ANTEROLATERAL THIGH; INDUCTIVE SCAFFOLD; BIOLOGIC SCAFFOLD; WALL REPAIR; DOG-MODEL;
D O I
10.2522/ptj.20150133
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. Electrodiagnosis can reveal the nerve and muscle changes following surgical placement of an extracellular matrix (ECM) bioscaffold for treatment of volumetric muscle loss (VML). Objective. The purpose of this study was to characterize nerve conduction study (NCS) and electromyography (EMG) changes following ECM bioscaffold placement in individuals with VML. The ability of presurgical NCS and EMG to be used as a tool to help identify candidates, who are likely to display improvements postsurgically also was explored. Design. A longitudinal case series design was used. Methods. The study was conducted at the McGowan Institute for Regenerative Medicine at the University of Pittsburgh. Eight individuals with a history of chronic VML participated. The intervention was surgical placement of an ECM bioscaffold at the site of VML. The strength of the affected region was measured using a handheld dynamometer, and electrophysiologic evaluation was conducted on the affected limb with standard method of NCS and EMG. All measurements were obtained the day before surgery and repeated 6 months after surgery. Results. Seven of the 8 participants had a preoperative electrodiagnosis of incomplete mononeuropathy within the site of VML. After ECM treatment, 5 of the 8 participants showed improvements in NCS amplitude or needle EMG parameters. The presence of electrical activity within the scaffold remodeling site was concomitant with clinical improvement in muscle strength. Limitations. This study had a small sample size, and participants served as their own controls. The electromyographers and physical therapists performing the evaluation were not blinded. Conclusions. Electrodiagnostic data provide objective evidence of physiological improvements in muscle function following ECM placement at sites of VML. Future studies are warranted to further investigate the potential of needle EMG as a predictor of successful outcomes following ECM treatment for VML.
引用
收藏
页码:540 / 549
页数:10
相关论文
共 51 条
  • [1] Evidence of innervation following extracellular matrix scaffold-mediated remodelling of muscular tissues
    Agrawal, Vineet
    Brown, Bryan N.
    Beattie, Allison J.
    Gilbert, Thomas W.
    Badylak, Stephen F.
    [J]. JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2009, 3 (08) : 590 - 600
  • [2] Increased neuromuscular transmission instability and motor unit remodelling with diabetic neuropathy as assessed using novel near fibre motor unit potential parameters
    Allen, Matti D.
    Stashuk, Daniel W.
    Kimpinski, Kurt
    Doherty, Timothy J.
    Hourigan, Maddison L.
    Rice, Charles L.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2015, 126 (04) : 794 - 802
  • [3] Morphologic study of small intestinal submucosa as a body wall repair device
    Badylak, S
    Kokini, K
    Tullius, B
    Simmons-Byrd, A
    Morff, R
    [J]. JOURNAL OF SURGICAL RESEARCH, 2002, 103 (02) : 190 - 202
  • [4] Badylak S, 2003, HEART SURG FORUM, V6, pE20
  • [5] Esophageal reconstruction with ECM and muscle tissue in a dog model
    Badylak, SF
    Vorp, DA
    Spievack, AR
    Simmons-Byrd, A
    Hanke, J
    Freytes, DO
    Thapa, A
    Gilbert, TW
    Nieponice, A
    [J]. JOURNAL OF SURGICAL RESEARCH, 2005, 128 (01) : 87 - 97
  • [6] Esophageal Preservation in Five Male Patients After Endoscopic Inner-Layer Circumferential Resection in the Setting of Superficial Cancer: A Regenerative Medicine Approach with a Biologic Scaffold
    Badylak, Stephen F.
    Hoppo, Toshitaka
    Nieponice, Alejandro
    Gilbert, Thomas W.
    Davison, Jon M.
    Jobe, Blair A.
    [J]. TISSUE ENGINEERING PART A, 2011, 17 (11-12) : 1643 - 1650
  • [7] RANGE OF VARIATIONS IN MOTOR UNIT POTENTIALS DURING RE-INNERVATION AFTER TRAUMATIC NERVE LESIONS IN HUMANS
    BORENSTEIN, S
    DESMEDT, JE
    [J]. ANNALS OF NEUROLOGY, 1980, 8 (05) : 460 - 467
  • [8] Extracellular matrix as an inductive scaffold for functional tissue reconstruction
    Brown, Bryan N.
    Badylak, Stephen F.
    [J]. TRANSLATIONAL RESEARCH, 2014, 163 (04) : 268 - 285
  • [9] Macrophage phenotype and remodeling outcomes in response to biologic scaffolds with and without a cellular component
    Brown, Bryan N.
    Valentin, Jolene E.
    Stewart-Akers, Ann M.
    McCabe, George P.
    Badylak, Stephen F.
    [J]. BIOMATERIALS, 2009, 30 (08) : 1482 - 1491
  • [10] BUCHTHAL F, 1982, MUSCLE NERVE, V5, pS52