Correcting motion artifacts of heart for intravascular optical coherence tomography images

被引:0
作者
Liu, Danni [1 ]
Liu, Yana [1 ]
Xin, Yi [1 ]
Li, Qin [1 ]
机构
[1] Beijing Inst Technol, Dept Biomed Engn, Beijing 100081, Peoples R China
来源
OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS X | 2020年 / 11553卷
基金
中国国家自然科学基金;
关键词
intravascular optical coherence tomography; coronary atherosclerotic plaque; motion artifacts; correcting algorithm; ANGIOGRAPHY; PHASE; IVUS; CT;
D O I
10.1117/12.2573961
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cardiovascular disease is one of the major diseases that cause human death. Atherosclerotic plaque rupture is the main pathogenesis of cardiovascular disease, which leads to coronary heart disease, such as myocardial ischemia, myocardial infarction, internal carotid atherosclerosis and other cardiovascular and cerebrovascular diseases. Intravascular optical coherence tomography (IVOCT) plays an important role in the diagnosis and treatment of cardiovascular diseases because of its high speed and high resolution. In the current various imaging examination method, clinician evaluate the coronary atherosclerotic plaque structural change by using intravascular ultrasound (IVUS) and IVOCT. IVOCT can provide micron size resolution, which is ten times of IVUS. However, the collected images have motion artifacts during the catheter is pulled back due to the periodic heartbeats. The artifacts would reduce the recognition accuracy of the plaques type and affect the preoperative planning and postoperative follow-up of percutaneous coronary intervention surgery. Based on the comprehensive analysis of the mechanism of motion artifacts and the characteristics of periodic cardiac motion, we designed a new algorithm to correct the rigid motion artifacts of coronary IVOCT images that caused by the heartbeat. This new algorithm can compensate part of translation to suppress of motion artifacts. Compared with the electrocardiogram control method, this algorithm does not need to discard the useful frames in the cardiac cycle, thus ensuring the integrity of the images.
引用
收藏
页数:8
相关论文
共 15 条
[1]   Cardiac phase extraction in IVUS sequences using 1-D Gabor filters [J].
Barajas, Joel ;
Caballero, Karla Lizbeth ;
Rodriguez, Oriol ;
Radeva, Petia .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :343-+
[2]   Approaching Artery Rigid Dynamics in IVUS [J].
Hernandez-Sabate, Aura ;
Gil, Debora ;
Fernandez-Nofrerias, Eduard ;
Radeva, Petia ;
Marti, Enric .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) :1670-1680
[3]  
Hisham MB, 2015, IEEE ST CONF RES DEV, P100, DOI 10.1109/SCORED.2015.7449303
[4]  
Hui Z, 2003, PROC SPIE, V5035, P135, DOI 10.1117/12.479884
[5]  
Li Jun-Shan, 2002, Mini-Micro Systems, V23, P695
[6]   Transstenotic pressure gradients: Measurement in swine-retrospectively ECG-gated 3D phase-contrast MR angiography versus endovascular pressure-sensing guidewires [J].
Lum, Darren P. ;
Johnson, Kevin M. ;
Paul, Russell K. ;
Turk, Aquilla S. ;
Consigny, Daniel W. ;
Grinde, Julie R. ;
Mistretta, Charles A. ;
Grist, Thomas M. .
RADIOLOGY, 2007, 245 (03) :751-760
[7]  
Regar E, 2003, Cardiovasc Radiat Med, V4, P198
[8]   Modelling of image-catheter motion for 3-D IVUS [J].
Rosales, Misael ;
Radeva, Petia ;
Rodriguez-Leor, Oriol ;
Gil, Debora .
MEDICAL IMAGE ANALYSIS, 2009, 13 (01) :91-104
[9]   3-D intravascular ultrasound (IVUS) and IVUS-palpography: insights into the mechanical behavior of the coronary vessel wall [J].
Schoenhagen, P .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (02) :153-155
[10]  
Sun K, 1998, 1998 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING - PROCEEDINGS, VOL 3, P601, DOI 10.1109/ICIP.1998.727335