DEMAT: A multi-institutional dosimetry audit of rotational and static intensity-modulated radiotherapy

被引:12
作者
Lafond, Caroline [1 ]
Chiavassa, Sophie [2 ]
Bertaut, Cindy [1 ]
Boussion, Nicolas [3 ]
Chapel, Nathalie [4 ]
Chapron, Lucie [5 ]
Coste, Frederic [6 ]
Crespin, Sylvain [7 ]
Dy, Gilles [8 ]
Faye, Papa Abdoulaye [2 ]
Leleu, Cyril [9 ]
Bouvier, Jeanne [1 ]
Madec, Ludovic [10 ]
Mesgouez, Jerome [11 ]
Palisson, Jeremy [12 ]
Vela, Anthony [13 ]
Delpon, Gregory [2 ]
机构
[1] Ctr Eugene Marquis, F-35042 Rennes, France
[2] Ctr Rene Gauducheau, Inst Cancerol Ouest, F-44805 Nantes, France
[3] CHRU, F-29609 Brest, France
[4] Clin Pasteur, F-29200 Brest, France
[5] Clin Armoricaine, F-22000 St Brieuc, France
[6] Pole Mutualiste, F-44600 St Nazaire, France
[7] CHD Oudairies, F-85925 La Roche Sur Yon, France
[8] Clin St Vincent, F-35760 St Gregoire, France
[9] CHI, F-29000 Quimper, France
[10] Ctr Baie, F-50300 Avranches, France
[11] Ctr Paul Papin, Inst Cancerol Ouest, F-49100 Angers, France
[12] Ctr Mallet Proux, F-53000 Laval, France
[13] Ctr Francois Baclesse, F-14000 Caen, France
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2016年 / 32卷 / 05期
关键词
IMRT; VMAT; Audit; TREATMENT PLANNING SYSTEMS; FILM DOSIMETRY; ARC THERAPY; DOSE DISTRIBUTIONS; VERIFICATION; CANCER;
D O I
10.1016/j.ejmp.2016.04.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Static beam intensity-modulated-radiation-therapy (IMRT) and/or Volumetric-Modulated-Arc-Therapy (VMAT) are now available in many regional radiotherapy departments. The aim of this multi-institutional audit was to design a new methodology based on radiochromic films to perform an independent quality control. Methods: A set of data were sent to all participating centres for two clinical localizations: prostate and Head and Neck (H&N) cancers. The agreement between calculations and measurements was verified in the Octavius phantom (PTW) by point measurements using ionization chambers and by 2D measurements using EBT3 radiochromic films. Due to uncertainties in the whole procedure, criteria were set to 5% and 3% in local dose and 3 mm in distance excluding doses lower than 10% of the maximum doses. No normalization point or area was used for the quantitative analysis. Results: 13 radiotherapy centres participated in this audit involving 28 plans (12 IMRT, 16 VMAT). For point measurements, mean errors were -0.18 +/- 1.54% and 0.00 +/- 1.58% for prostate and H&N cases respectively. For 2D measurements with 5%/3 mm criteria, gamma map analysis showed a pixel pass rate higher than 95% for prostate and H&N. Mean gamma index was lower than 0.4 for prostate and 0.5 for H&N. Both techniques yielded similar results. Conclusion: This study showed the feasibility of an independent quality control by peers for conventional IMRT and VMAT. Results from all participating centres were found to be in good agreement. This regional study demonstrated the feasibility of our new methodology based on radiochromic films without dose normalization on a specific point. (C) 2016 Associazione Italiana di Fisica Medica Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:664 / 670
页数:7
相关论文
共 28 条
  • [1] Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification
    Borca, Valeria Casanova
    Pasquino, Massimo
    Russo, Giuliana
    Grosso, Pierangelo
    Cante, Domenico
    Sciacero, Piera
    Girelli, Giuseppe
    La Porta, Maria Rosa
    Tofani, Santi
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (02): : 158 - 171
  • [2] Static and rotational intensity modulated techniques for head-neck cancer radiotherapy: A planning comparison
    Broggi, Sara
    Perna, Lucia
    Bonsignore, Francesco
    Rinaldin, Giuseppe
    Fiorino, Claudio
    Chiara, Anna
    Frigerio, Cristina
    Butti, Ivana
    Sangalli, Giulia
    Dell'Oca, Italo
    Di Muzio, Nadia
    Cattaneo, Giovanni Mauro
    Declich, Fausto
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (08): : 973 - 979
  • [3] A national dosimetric audit of IMRT
    Budgell, Geoff
    Berresford, Joe
    Trainer, Michael
    Bradshaw, Ellie
    Sharpe, Peter
    Williams, Peter
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 (02) : 246 - 252
  • [4] A multi-institutional dosimetry audit of rotational intensity-modulated radiotherapy
    Clark, Catharine H.
    Hussein, Mohammad
    Tsang, Yatman
    Thomas, Russell
    Wilkinson, Dean
    Bass, Graham
    Snaith, Julia
    Gouldstone, Clare
    Bolton, Steve
    Nutbrown, Rebecca
    Venables, Karen
    Nisbet, Andrew
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 113 (02) : 272 - 278
  • [5] Dosimetry audit for a multi-centre IMRT head and neck trial
    Clark, Catharine H.
    Hansen, Vibeke Nordmark
    Chantler, Hannah
    Edwards, Craig
    James, Hayley V.
    Webster, Gareth
    Miles, Elizabeth A.
    Urbano, M. Teresa Guerrero
    Bhide, Shree A.
    Bidmead, A. Margaret
    Nutting, Christoper M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 93 (01) : 102 - 108
  • [6] A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation
    Depuydt, T
    Van Esch, A
    Huyskens, DP
    [J]. RADIOTHERAPY AND ONCOLOGY, 2002, 62 (03) : 309 - 319
  • [7] Quantification of beam complexity in intensity-modulated radiation therapy treatment plans
    Du, Weiliang
    Cho, Sang Hyun
    Zhang, Xiaodong
    Hoffman, Karen E.
    Kudchadker, Rajat J.
    [J]. MEDICAL PHYSICS, 2014, 41 (02)
  • [8] A national dosimetry audit of intraoperative radiotherapy
    Eaton, D. J.
    Earner, B.
    Faulkner, P.
    Dancer, N.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1032)
  • [9] Multicentre treatment planning inter-comparison in a national context: The liver stereotactic ablative radiotherapy case
    Esposito, Marco
    Maggi, Giulia
    Marino, Carmelo
    Bottalico, Laura
    Cagni, Elisabetta
    Carbonini, Claudia
    Casale, Michelina
    Clemente, Stefania
    D'Alesio, Valentina
    Fedele, David
    Giglioli, Francesca Romana
    Landoni, Valeria
    Martinotti, Anna
    Nigro, Roberta
    Strigari, Lidia
    Villaggi, Elena
    Mancosu, Pietro
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 277 - 283
  • [10] IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119
    Ezzell, Gary A.
    Burmeister, Jay W.
    Dogan, Nesrin
    LoSasso, Thomas J.
    Mechalakos, James G.
    Mihailidis, Dimitris
    Molineu, Andrea
    Palta, Jatinder R.
    Ramsey, Chester R.
    Salter, Bill J.
    Shi, Jie
    Xia, Ping
    Yue, Ning J.
    Xiao, Ying
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 5359 - 5373