Dominant Pole Placement with Modified PID Controllers

被引:11
作者
Du, Huanchao [1 ]
Hu, Xiaoguang [1 ]
Ma, Chaoqun [1 ]
机构
[1] Beihang Univ, State Key Lab Virtual Real Technol & Syst, Beijing 100191, Peoples R China
关键词
Dominant pole placement; modified PID controller; pole-zero cancellation; zero placement;
D O I
10.1007/s12555-018-0642-4
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, the limitations of the standard PID controller for dominant pole placement has been analyzed. Study shows that the modified PID controller, such as PI-D, I-PD, PI-PD and PD-PID controller, is an alternative to solve this problem. For the PI-PD and PD-PID controller, the zeros can be placed on the poles that are close to the specified dominant poles. The conditions for the existence of the dominant poles could be relaxed by pole-zero cancellation. Results show that a good dominant effect with fast response can be realized by the modified PID controllers.
引用
收藏
页码:2833 / 2838
页数:6
相关论文
共 13 条
[1]  
Astrom K J., 2006, ISA - The Instrumentation, Systems and Automation Society
[2]  
Branica I, 2002, ICES 2002: 9TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS I-111, CONFERENCE PROCEEDINGS, P1247, DOI 10.1109/ICECS.2002.1046480
[3]  
Dincel E, 2016, 2016 INTERNATIONAL CONFERENCE ON CONTROL, DECISION AND INFORMATION TECHNOLOGIES (CODIT), P741, DOI 10.1109/CoDIT.2016.7593655
[4]  
Dorf RC., 2001, Modern Control Systems, P232
[5]  
Li YY, 2011, CHIN CONTR CONF, P3756
[6]   New result on PID controller design of LTI systems via dominant eigenvalue assignment [J].
Liu, Jianchang ;
Wang, Honghai ;
Zhang, Yu .
AUTOMATICA, 2015, 62 :93-97
[7]  
Ogata K., 2010, MODERN CONTROL ENG
[8]  
Persson P., 1992, IFAC Proc, V25, P377, DOI DOI 10.1016/S1474-6670(17)50763-6
[9]  
Tang WJ, 2006, 2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, P2796
[10]   Guaranteed dominant pole placement with PID controllers [J].
Wang, Qing-Guo ;
Zhang, Zhiping ;
Astrom, Karl Johan ;
Chek, Lee See .
JOURNAL OF PROCESS CONTROL, 2009, 19 (02) :349-352