Assessing bioequivalence of generic modified-release antiepileptic drugs

被引:15
作者
Johnson, Emily L. [1 ]
Chang, Yi-Ting [2 ]
Davit, Barbara [3 ]
Gidal, Barry E. [4 ]
Krauss, Gregory L. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Neurol, Baltimore, MD 21205 USA
[2] Johnson & Johnson, New Brunswick, NJ USA
[3] Merck & Co Inc, Kenilworth, NJ USA
[4] Univ Wisconsin, Sch Pharm, 425 N Charter St, Madison, WI 53706 USA
关键词
EXTENDED-RELEASE; IMMEDIATE-RELEASE; DOSING IRREGULARITIES; FORMULATIONS; EPILEPSY; CARBAMAZEPINE; TOLERABILITY; LAMOTRIGINE; ABSORPTION; PHENYTOIN;
D O I
10.1212/WNL.0000000000002607
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives:The purpose of this study was to determine how closely generic modified-release antiepileptic drugs (MR-AEDs) resemble reference (brand) formulations by comparing peak concentrations (Cmax), total absorption (area under the curve [AUC]), time to Cmax (Tmax), intersubject variability, and food effects between generic and reference products.Methods:We tabulated Cmax and AUC data from the bioequivalence (BE) studies used to support the approvals of generic Food and Drug Administration-approved MR-AEDs. We compared differences in 90% confidence intervals of the generic/reference AUC and Cmax geometric mean ratios, and intersubject variability, Tmax and delivery profiles and food effects.Results:Forty-two MR-AED formulations were studied in 3,175 healthy participants without epilepsy in 97 BE studies. BE ratios for AUC and Cmax were similar between most generic and reference products: AUC ratios varied by >15% in 11.4% of BE studies; Cmax varied by >15% in 25.8% of studies. Tmax was more variable, with >30% difference in 13 studies (usually delayed in the fed compared to fasting BE studies). Generic and reference MR products had similar intersubject variability. Immediate-release AEDs showed less intersubject variability in AUC than did MR-AEDs.Conclusions:Most generic and reference MR-AEDs have similar AUC and Cmax values. Ratios for some products, however, are near acceptance limits and Tmax values may vary. Food effects are common with MR-AED products. High variability in pharmacokinetic values for once-a-day MR-AEDs suggests their major advantage compared to immediate-release AED formulations may be the convenience of less frequent dosing to improve adherence.
引用
收藏
页码:1597 / 1604
页数:8
相关论文
共 25 条
[21]   What do the suffixes - XR, ER, Chrono, Chronosphere - really mean as it pertains to modified-release antiepileptic drugs? [J].
Reed, R. C. ;
Meinhold, J. ;
Dutta, S. ;
Liu, W. ;
Qiu, Y. .
JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 2010, 35 (04) :373-383
[22]  
Riethorst D., 2015, J PHARM SCI
[23]   Formulation-dependent food effects demonstrated for nifedipine modified-release preparations marketed in the European Union [J].
Schug, BS ;
Brendel, E ;
Wolf, D ;
Wonnemann, M ;
Wargenau, M ;
Blume, HH .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2002, 15 (03) :279-285
[24]   Generic lamotrigine versus brand-name Lamictal bioequivalence in patients with epilepsy: A field test of the FDA bioequivalence standard [J].
Ting, Tricia Y. ;
Jiang, Wenlei ;
Lionberger, Robert ;
Wong, Jessica ;
Jones, Jace W. ;
Kane, Maureen A. ;
Krumholz, Allan ;
Temple, Robert ;
Polli, James E. .
EPILEPSIA, 2015, 56 (09) :1415-1424
[25]   Effect of food on absorption of Dilantin Kapseals and Mylan extended phenytoin sodium capsules [J].
Wilder, BJ ;
Leppik, I ;
Hietpas, TJ ;
Cloyd, JC ;
Randinitis, EJ ;
Cook, J .
NEUROLOGY, 2001, 57 (04) :582-589