Simultaneous extraction and preconcentration of three beta (ß)-blockers in biological samples with an efficient magnetic dispersive micro-solid phase extraction procedure employing in situ sorbent modification

被引:20
作者
Abadi, Mohammad Ameri Akhtiar [1 ]
Mahboubeh, Masrournia A. [1 ]
Abedi, Mohamad Reza [2 ]
机构
[1] Islamic Azad Univ, Mashhad Branch, Dept Chem, Mashhad, Razavi Khorasan, Iran
[2] Islamic Azad Univ, Quchan Branch, Dept Appl Chem, Quchan, Iran
关键词
Beta (beta)-blockers; In situ sorbent modification; Magnetic dispersive micro-solid phase extraction; Design of experiment; Humanurine samples; Plasma samples; PERFORMANCE LIQUID-CHROMATOGRAPHY; GRAPHENE OXIDE; HUMAN PLASMA; MASS-SPECTROMETRY; HUMAN URINE; BLOCKERS; MICROEXTRACTION; DRUGS; SEPARATION; REMOVAL;
D O I
10.1016/j.microc.2021.105937
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A straightforward and sensitive magnetic dispersive micro-solid phase extraction based on in situ sorbent modification in sample solution was developed for the simultaneous extraction of metoprolol, atenolol, and propranolol (three beta-blockers) in human plasma and urine samples. To prepare a suitable sorbent, magnetic graphene oxide as a magnetic core was synthesized and modified with sodium dodecyl sulfate in the sample solution containing the analytes. In the procedure, the sorbent synthesis and the analyte extraction were simultaneously performed in the sample solution, which leads to a reduction in the time and cost of the determination of the analytes. Three surfactants such as cetyltrimethylammonium bromide, triton X100, and sodium dodecyl sulfate were utilized to modify the magnetic graphene oxide composites and their effects on the extraction of beta-blockers were investigated. The effective variables in the microextraction process of the analytes were optimized based on a design of experiment strategy. Under the optimal conditions, the dynamic ranges of linear were 5-10000, 50-5000, and 10-5000 ng mL(-1) with method detection limits of 0.8, 10, and 2 ng mL(-1) for Atenolol, Metoprolol, and Propranolol, respectively The relative standard deviations of the intra-day and inter-day were less than 2.96% and 5.35% (n = 5) for the determination of the analytes, respectively. A suitable enrichment factors of 14, 16, and 18 were obtained for the determination of metoprolol, atenolol, and propranolol, respectively. Finally, the suggested method was successfully applied to measure the beta-blockers in several plasma and urine samples of healthy volunteers without taking drugs and patient volunteers with taking drugs. The method shows suitable relative recoveries in the ranges of 82.4-109.4% and 77.6-95.9% for the analysis of urine and plasma samples with relative standard deviations between 3.1 and 6.7% for the determination of all analytes, respectively.
引用
收藏
页数:11
相关论文
共 61 条
[1]   Reduced graphene oxide conjugate thymine as a new probe for ultrasensitive and selective fluorometric determination of mercury(II) ions [J].
Abdelhamid, Hani Nasser ;
Wu, Hui-Fen .
MICROCHIMICA ACTA, 2015, 182 (9-10) :1609-1617
[2]   Chemometric approach to the optimization of HS-SPME/GC-MS for the determination of multiclass pesticide residues in fruits and vegetables [J].
Abdulra'uf, Lukman Bola ;
Tan, Guan Huat .
FOOD CHEMISTRY, 2015, 177 :267-273
[3]  
Abruzzo A., 2020, J PHARM SCI-US
[4]   Chiral Separation of β-Adrenergic Blockers in Human Plasma by SPE-HPLC [J].
Ali, Imran ;
Al-Othman, Zeid A. ;
Hussain, Afzal ;
Saleem, Kishwar ;
Aboul-Enein, Hassan Y. .
CHROMATOGRAPHIA, 2011, 73 (3-4) :251-256
[5]   Determination of clenbuterol in human urine and serum by solid-phase microextraction coupled to liquid chromatography [J].
Aresta, A. ;
Calvano, C. D. ;
Palmisano, F. ;
Zambonin, C. G. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (03) :641-645
[6]   Magnetic solid-phase extraction of imatinib and doxorubicin as cytostatic drugs by Fe3O4/graphene oxide nanocomposite [J].
Arvand, Majid ;
Masouleh, Afshin Nickdoust .
JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (08) :1673-1682
[7]   Synthesis of Stabilized Myrrh-Capped Hydrocolloidal Magnetite Nanoparticles [J].
Atta, Ayman M. ;
Al-Lohedan, Hamad A. ;
Al-Hussain, Sami A. .
MOLECULES, 2014, 19 (08) :11263-11278
[8]   Modeling and optimizing of adsorption removal of Reactive Blue 19 on the magnetite/graphene oxide nanocomposite via response surface methodology [J].
Ayazi, Zahra ;
Khoshhesab, Zahra Monsef ;
Norouzi, Somayeh .
DESALINATION AND WATER TREATMENT, 2016, 57 (52) :25301-25316
[9]   Low cost thiol-functionalized mesoporous silica, KIT-6-SH, as a useful adsorbent for cadmium ions removal: A study on the adsorption isotherms and kinetics of KIT-6-SH [J].
Bagheri, Saman ;
Amini, Mostafa M. ;
Behbahani, Mohammad ;
Rabiee, Ghazal .
MICROCHEMICAL JOURNAL, 2019, 145 :460-469
[10]   UHPLC method for the simultaneous determination of β-blockers, isoflavones and their metabolites in human urine [J].
Baranowska, Irena ;
Magiera, Sylwia ;
Baranowski, Jacek .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (9-10) :615-626