Analysis of off-flavor compounds in water at sub part per trillion level by GUMS with programmable temperature vaporizer inlet

被引:6
作者
Zhang, L. [1 ]
Hu, R. [1 ]
Yang, Z. [1 ]
机构
[1] Singapore Util Int, Ctr Adv Water Technol, Innovat Ctr, Nanyang Technol Univ, Singapore 637723, Singapore
关键词
GC-MS; large volume injection (LVI); off-flavor; programmable temperature vaporizing (PTV); solid phase micro-extraction (SPME); water;
D O I
10.2166/wst.2006.889
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Earthy-musty off-flavor problems in water samples are due to organic compounds present at the sub pail per trillion level. Most of the studies in the analysis of tastes and odorous compounds focus on the extraction pre concentration technique, with detection at picogram per liter level of the earthy-musty off-flavor compounds, which are difficult to achieve. The objective of this study is to develop a new method involving the GC/MS with programmable temperature vaporizer (PTV) inlet via large volume injection (LVI) or solid phase micro-extraction (SPME), to attain analytical sensitivity equal to or better than olfactory sensitivity. Six "earthy-musty" organic compounds; 2-methylisoborneol (MIB); geosmin; 2, 4, 6-trichloroanisole (2,4,6-TCA); 2, 3, 6-trichloroanisole (2,3,6-TCA); 2, 3, 4-trichloroanisole (2,3,4-TCA); and 2, 4, 6-tribromoanisole (2,4,6-TBA), were used as probes for this study. It was found that LVI via PTV could greatly improve system sensitivity towards the detection of off-flavor compounds with low volatility such as haloanisoles. For those off-flavor compounds with high volatility, eg MIB, SPME coupled with PTV-GC-MS with cool initial temperature has always demonstrated the best sensitivity.
引用
收藏
页码:335 / 344
页数:10
相关论文
共 28 条
[1]  
[Anonymous], 1987, IDENTIFICATION TREAT
[2]  
ANSELME C, 1985, CORRELATION SENSORY
[3]   Pesticide residue analysis in waters by solid-phase microextraction coupled to gas chromatography-tandem mass spectrometry [J].
Arrebola, FJ ;
Aguado, SC ;
Sánchez-Morito, N ;
Frenich, AG ;
Vidal, JLM .
ANALYTICAL LETTERS, 2004, 37 (01) :99-117
[4]   Determination of trace levels of taste and odor compounds in water by microextraction and gas chromatography ion trap detection mass spectrometry [J].
Bao, ML ;
Barbieri, K ;
Burrini, D ;
Griffini, O ;
Pantani, F .
WATER RESEARCH, 1997, 31 (07) :1719-1727
[5]  
BENANOU D, 2003, STIR BAR SORPTIVE EX
[6]  
Brück M, 1999, ASTRON GEOPHYS, V40, P6
[7]   Determination of odorous mixed chloro-bromoanisoles in water by solid-phase micro-extraction and gas chromatography-mass detection [J].
Díaz, A ;
Ventura, F ;
Galceran, T .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1064 (01) :97-106
[8]   Programmed temperature vaporiser-based injection in capillary gas chromatography [J].
Engewald, W ;
Teske, J ;
Efer, J .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :259-278
[9]   ON-COLUMN INJECTION OF LARGE SAMPLE VOLUMES USING THE RETENTION GAP TECHNIQUE IN CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K ;
KARRER, G ;
RIEKKOLA, ML .
JOURNAL OF CHROMATOGRAPHY, 1985, 334 (02) :129-155
[10]   ACTINOMYCETES AS A FACTOR IN ODOR PROBLEMS AFFECTING DRINKING-WATER FROM THE NORTH SASKATCHEWAN RIVER [J].
JENSEN, SE ;
ANDERS, CL ;
GOATCHER, LJ ;
PERLEY, T ;
KENEFICK, S ;
HRUDEY, SE .
WATER RESEARCH, 1994, 28 (06) :1393-1401