The Accuracy of Three-Dimensional CT Scan Software in Predicting Prosthetic Utilization in Total Shoulder Arthroplasty

被引:9
作者
Baumgarten, Keith M. [1 ,2 ]
Radtke, Logan [2 ]
机构
[1] Univ South Dakota, Orthoped Inst, Sioux Falls, SD 57105 USA
[2] Univ South Dakota, Sanford Sch Med, Sioux Falls, SD 57105 USA
关键词
PATIENT-SPECIFIC INSTRUMENTATION; SIZE PREDICTION; CUTTING BLOCKS; IMPLANT SIZE; COMPONENT; INCLINATION; SURGEON;
D O I
10.5435/JAAOS-D-21-00641
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Recent innovations in shoulder arthroplasty include three-dimensional (3D) CT software imaging that can be used to predict which prosthetic implants will be used intraoperatively. Correct prediction of the implants may optimize supply chain logistics for the surgeon, hospital, ambulatory surgery center, and the implant company. The purpose of this study was to examine a single surgeon's experience with this software to determine its predictive accuracy in determining which implants would be used intraoperatively. Methods: A retrospective review of patients undergoing total shoulder arthroplasty (TSA) performed by a single surgeon was performed. Inclusion criteria were patients undergoing anatomic (aTSA) or reverse (rTSA) TSA examined preoperatively with the 3D CT planning software. A chart review was performed to compare the accuracy of the preoperative plan in predicting the actual prostheses implanted at surgery. Results: Two hundred seventy-eight shoulders from 260 patients were included. One hundred fifty-one shoulders underwent aTSA, and 127 shoulders underwent rTSA. The surgeon was able to predict the type of arthroplasty (anatomic versus reverse) implanted in 269 of 278 (97%) shoulders. Using the 3D CT software, the surgeon was able to predict all the implants implanted in 68 shoulders (24%). For aTSA, 3D CT imaging successfully predicted all implants implanted in 43 shoulders (28%), glenoid implants implanted in 120 of 148 shoulders (81%), and humeral implants implanted in 54 shoulders (36%). For rTSA, 3D CT imaging successfully predicted all implants implanted in 26 shoulders (20%), glenoid implants implanted in 106 shoulders (83%), and humeral implants implanted in 39 shoulders (31%). Conclusions: The 3D CT software combined with surgeon's judgment provided a high accuracy (97%) in determining the type of arthroplasty, a moderately high accuracy in determining the glenoid implants (81% to 83%), a low accuracy in determining humeral implants (31% to 36%), and a low accuracy in determining all prostheses used for each surgery (20% to 28%).
引用
收藏
页码:E223 / E232
页数:10
相关论文
共 30 条
[1]   Risk of Perforation Is High During Corrective Reaming of Retroverted Glenoids: A Computer Simulation Study [J].
Aleem, Alexander W. ;
Orvets, Nathan D. ;
Patterson, Brendan C. ;
Chamberlain, Aaron M. ;
Keener, Jay D. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2018, 476 (08) :1612-1619
[2]  
Amini MH, 2017, JBJS ESSENT SURG TEC, V7, DOI 10.2106/JBJS.ST.17.00009
[3]   Patient specific cutting blocks are currently of no proven value [J].
Barrack, R. L. ;
Ruh, E. L. ;
Williams, B. M. ;
Ford, A. D. ;
Foreman, K. ;
Nunley, R. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11) :95-99
[4]   Automated Three-Dimensional Measurement of Glenoid Version and Inclination in Arthritic Shoulders [J].
Boileau, Pascal ;
Cheval, Damien ;
Gauci, Marc-Olivier ;
Holzer, Nicolas ;
Chaoui, Jean ;
Walch, Gilles .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (01) :57-65
[5]   Reliability and accuracy of templating the proximal humeral component for shoulder arthroplasty [J].
Buzzell, Jonathan E. ;
Lutton, David M. ;
Shyr, Yu ;
Neviaser, Robert J. ;
Lee, Donald H. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (05) :728-733
[6]   Pre-operative planning in THA. Part III: do implant size prediction and offset restoration influence functional outcomes after THA? [J].
Cech, Alexandre ;
Kase, Masanori ;
Kobayashi, Hideo ;
Pagenstert, Geert ;
Carrillon, Yannick ;
O'Loughlin, Padhraig F. ;
Ait-Si-Selmi, Tarik ;
Bothorel, Hugo ;
Bonnin, Michel P. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (04) :563-573
[7]   Significant differences between manufacturer and surgeon in the accuracy of final component size prediction with CT-based patient-specific instrumentation for total knee arthroplasty [J].
Cucchi, Davide ;
Menon, Alessandra ;
Compagnoni, Riccardo ;
Ferrua, Paolo ;
Fossati, Chiara ;
Randelli, Pietro .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (11) :3317-3324
[8]   Patient-specific glenoid guides provide accuracy and reproducibility in total shoulder arthroplasty [J].
Gauci, M. O. ;
Boileau, P. ;
Baba, M. ;
Chaoui, J. ;
Walch, G. .
BONE & JOINT JOURNAL, 2016, 98B (08) :1080-1085
[9]   Patient-Specific Instrumentation Does Not Shorten Surgical Time: A Prospective, Randomized Trial [J].
Hamilton, William G. ;
Parks, Nancy L. ;
Saxena, Arjun .
JOURNAL OF ARTHROPLASTY, 2013, 28 (08) :96-100
[10]   Patient-specific instrument guidance of glenoid component implantation reduces inclination variability in total and reverse shoulder arthroplasty [J].
Heylen, Steven ;
Van Haver, Annemieke ;
Vuylsteke, Kristien ;
Declercq, Geert ;
Verborgt, Olivier .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (02) :186-192