Treatment simulation approaches for the estimation of the distributions of treatment quality parameters generated by geometrical uncertainties

被引:23
作者
Baum, C [1 ]
Alber, M [1 ]
Birkner, M [1 ]
Nüsslin, F [1 ]
机构
[1] Univ Kliniken Radioonkol Tubingen, D-72076 Tubingen, Germany
关键词
D O I
10.1088/0031-9155/49/24/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Geometric uncertainties arise during treatment planning and treatment and mean that dose-dependent parameters such as EUD are random variables with a patient specific probability distribution. Treatment planning with highly conformal treatment techniques such as intensity modulated radiation therapy requires new evaluation tools which allow us to estimate this influence of geometrical uncertainties on the probable treatment dose for a planned dose distribution. Monte Carlo simulations of treatment courses with recalculation of the dose according to the daily geometric errors are a gold standard for such an evaluation. Distribution histograms which show the relative frequency of a treatment quality parameter in the treatment simulations can be used to evaluate the potential risks and chances of a planned dose distribution. As treatment simulations with dose recalculation are very time consuming for sufficient statistical accuracy, it is proposed is mainly determined by the systematic and random component of the geometrical uncertainties. Comparison of the parameter space simulation method with the gold standard for prostate cases and a head and neck case shows good agreement as long as the number of fractions is high enough and the influence of tissue inhomogeneities and surface curvature on the dose is small.
引用
收藏
页码:5475 / 5488
页数:14
相关论文
共 18 条
[1]  
Alber M., 2003, International Journal of Radiation Oncology Biology Physics, V57, pS208, DOI 10.1016/S0360-3016(03)01016-2
[2]   An objective function for radiation treatment optimization based on local biological measures [J].
Alber, M ;
Nüsslin, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (02) :479-493
[3]   The required number of treatment imaging days for an effective off-line correction of systematic errors in conformal radiotherapy of prostate cancer - a radiobiological analysis [J].
Amer, AM ;
Mackay, RI ;
Roberts, SA ;
Hendry, JH ;
Williams, PC .
RADIOTHERAPY AND ONCOLOGY, 2001, 61 (02) :143-150
[4]   The effect of set-up uncertainties, contour changes, and tissue inhomogeneities on target dose-volume histograms [J].
Cho, BCJ ;
van Herk, M ;
Mijnheer, BJ ;
Bartelink, H .
MEDICAL PHYSICS, 2002, 29 (10) :2305-2318
[5]   The impact of geometric uncertainty on hypofractionated external beam radiation therapy of prostate cancer [J].
Craig, T ;
Moiseenko, V ;
Battista, J ;
Van Dyk, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (03) :833-842
[6]   Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. I. The effect of shift invariance [J].
Craig, T ;
Battista, J ;
Van Dyk, J .
MEDICAL PHYSICS, 2003, 30 (08) :2001-2011
[7]   Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. II. The effect of a finite number of fractions [J].
Craig, T ;
Battista, J ;
Van Dyk, J .
MEDICAL PHYSICS, 2003, 30 (08) :2012-2020
[8]   Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm [J].
Fippel, M .
MEDICAL PHYSICS, 1999, 26 (08) :1466-1475
[9]   Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC [J].
Kawrakow, I ;
Fippel, M .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08) :2163-2183
[10]  
Keall P. J., 1999, Australasian Physical and Engineering Sciences in Medicine, V22, P48