Fluid Attenuated Inversion Recovery (FLAIR) Imaging of the Normal Brain: Comparisons between Under the Conditions of 3.0 Tesla and 1.5 Tesla

被引:4
作者
Sohn, Chul-Ho [1 ,2 ,3 ]
Sevick, Robert J. [3 ,4 ]
Frayne, Richard [3 ,4 ]
Chang, Hyuk-Won [5 ]
Kim, Sang-Pyo [2 ,6 ]
Kim, Dae-Kwang [2 ,7 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[2] Keimyung Univ, Dept Brain Res Ctr, Dongsan Med Ctr, Taegu 700712, South Korea
[3] Univ Calgary, Dept Radiol, Calgary, AB, Canada
[4] Univ Calgary, Seaman Family MR Res Ctr, Calgary, AB, Canada
[5] Keimyung Univ, Dongsan Med Ctr, Dept Radiol, Taegu 700712, South Korea
[6] Keimyung Univ, Dongsan Med Ctr, Dept Pathol, Taegu 700712, South Korea
[7] Keimyung Univ, Dongsan Med Ctr, Dept Anat, Taegu 700712, South Korea
关键词
Magnetic resonance (MR); Fluid attenuated inversion recovery (FLAIR); Normal Brain; 3.0; Tesla; MULTIPLE-SCLEROSIS; WHITE-MATTER; MR-IMAGES; IRON;
D O I
10.3348/kjr.2010.11.1.19
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to evaluate the differences in normal brain MRI findings between under 3.0 Tesla (T) and 1.5T MRI conditions with the use of the fluid attenuated inversion recovery (FLAIR) sequences. Materials and Methods: Eleven normal adults underwent imaging with the use of the FLAIR sequences on both 1.5T and 3.0T scanners. Two neuroradiologists compared the signal intensity (SI) of the centrum semiovale (CS), pulvinar thalami (PT) and normal iron deposit structures (IDSs) on the 3.0T and 1.5T FLAIR images, and they evaluated three MRI findings qualitatively: high SI of CS; low SI of PT; low SI of IDS. We also evaluated signal-to-noise ratios (SNRs) for the CS, PT, red nucleus and cerebellar dentate nucleus on the FLAIR images. Results: Based on qualitative analyses, the 3.0T FLAIR images showed all three MRI findings for all cases. Low SI for the PT in seven cases (64%), high SI of the CS in one case (9%) and low SI of the cerebellar dentate nucleus in one case (9%) were visualized only on 3.0T FLAIR images. The mean SNRs of the PT, red nucleus and dentate nucleus in patients where 3.0T FLAIR imaging was performed were significantly lower as compared with the SNRs on 1.5T FLAIR images. The SNR of the CS was not significantly different between under the two magnetic field strengths (p > 0.05). Conclusion: We have demonstrated that normal, high and low SIs of the CS, PT and IDS on 3.0T FLAIR images were depicted more frequently and more prominently as compared with those on 1.5T FLAIR images in normal adult brains.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 14 条
[1]   Sensitivity of T2-weighted FSE sequences towards physiological iron depositions in normal brains at 1.5 and 3.0 T [J].
Allkemper, T ;
Schwindt, W ;
Maintz, D ;
Heindel, W ;
Tombach, B .
EUROPEAN RADIOLOGY, 2004, 14 (06) :1000-1004
[2]   3 T MRI: Advances in brain imaging [J].
Alvarez-Linera, Juan .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 67 (03) :415-426
[3]  
Ashikaga R, 1999, AM J NEURORADIOL, V20, P427
[4]  
Bernstein MA, 2001, MAGNET RESON MED, V46, P955, DOI 10.1002/mrm.1282
[5]   REDUCED SIGNAL INTENSITY ON MR IMAGES OF THALAMUS AND PUTAMEN IN MULTIPLE-SCLEROSIS - INCREASED IRON CONTENT [J].
DRAYER, B ;
BURGER, P ;
HURWITZ, B ;
DAWSON, D ;
CAIN, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (02) :357-363
[6]   THE INTRINSIC SIGNAL-TO-NOISE RATIO IN NMR IMAGING [J].
EDELSTEIN, WA ;
GLOVER, GH ;
HARDY, CJ ;
REDINGTON, RW .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) :604-618
[7]   Fast FLAIR of the brain: The range of appearances in normal subjects and its application to quantification of white-matter disease [J].
GawneCain, ML ;
Silver, NC ;
Moseley, IF ;
Miller, DH .
NEURORADIOLOGY, 1997, 39 (04) :243-249
[8]   HIGH SIGNAL REGIONS IN NORMAL WHITE MATTER SHOWN BY HEAVILY T2-WEIGHTED CSF NULLED IR SEQUENCES [J].
HAJNAL, JV ;
DECOENE, B ;
LEWIS, PD ;
BAUDOUIN, CJ ;
COWAN, FM ;
PENNOCK, JM ;
YOUNG, IR ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (04) :506-513
[9]   MR contrast of ferritin and hemosiderin in the brain: comparison among gradient-echo, conventional spin-echo and fast spin-echo sequences [J].
Haque, TL ;
Miki, Y ;
Kanagaki, M ;
Takahashi, T ;
Yamamoto, A ;
Konishi, J ;
Nozaki, K ;
Hashimoto, N ;
Konishi, J .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (03) :230-236
[10]   Comparison of 1.5T and 3T 1H MR spectroscopy for human brain tumors [J].
Kim, Ji-hoon ;
Chang, Kee-Hyun ;
Na, Dong Gyu ;
Song, In Chan ;
Kim, Seung Ja ;
Kwon, Bae Ju ;
Han, Moon Hee .
KOREAN JOURNAL OF RADIOLOGY, 2006, 7 (03) :156-161