Multipulse controlled ac-dc converters for harmonic mitigation and reactive power management

被引:16
作者
Peterson, M. [1 ]
Singh, B. N. [2 ]
机构
[1] Entergy Inc, Power Transmiss & Distribut Technol, New Orleans, LA 70113 USA
[2] John Deere Inc, Power Elect & Motor Control, Fargo, ND 58102 USA
关键词
RECTIFIER;
D O I
10.1049/iet-pel.2007.0199
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Multipulse thyristor converters are being employed in industrial applications to control output current/voltage through adjustment of the thyristors' triggering angle. For reduced loading conditions, the triggering angle may be raised resulting in low power factor and a high total harmonic distortion (THD) in the source current. In addition, under light loads, overall system efficiency is reduced with rectifiers operated below capacity, and continuous operation of these rectifiers and switching devices reduces their life expectancy. An attractive alternative to meet reduced load conditions while maintaining improved power quality, system efficiency, reliability and device lifespan is proposed. The performance of multipulse thyristor converters is investigated with the proposed control scheme, which involves simultaneous and/or selective control of the thyristor triggering angle and converter pulse number. For pulse control, an appropriate rectifier or pair of rectifiers is disabled or enabled from the high current load depending on the current loading conditions. An 18-pulse parallel thyristor converter is selected to verify the proposed technique. The mathematical model of the 18-pulse thyristor converter is derived and the corresponding simulation model is developed to analyse the performance of the proposed control technique in terms of the above-mentioned criteria.
引用
收藏
页码:443 / 455
页数:13
相关论文
共 26 条
[1]  
*ABB POW SYST, STAT VAR COMP DC FUR
[2]   A MODIFIED PARALLEL HVDC CONVERTER FOR 24 PULSE OPERATION [J].
ARRILLAGA, J ;
VILLABLANCA, M .
IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (01) :231-231
[3]  
Blauth YB, 1998, APPL POWER ELECT CO, P970, DOI 10.1109/APEC.1998.654016
[4]   Polyphase transformer arrangements with reduced kVA capacities for harmonic current reduction in rectifier-type utility interface [J].
Choi, S ;
Enjeti, PN ;
Pitel, IJ .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1996, 11 (05) :680-690
[5]  
Choi S, 1997, IEEE T IND APPL, V33, P531, DOI 10.1109/28.568020
[6]   A new active interphase reactor for 12-pulse rectifiers provides clean power utility interface [J].
Choi, S ;
Enjeti, PN ;
Lee, HH ;
Pitel, IJ .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (06) :1304-1311
[7]  
Choi S, 2002, IEEE T IND APPL, V38, P131, DOI 10.1109/28.980367
[8]  
Choi SW, 1996, PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, P1985
[9]   NOVEL TRANSFORMER CONNECTION TO IMPROVE CURRENT SHARING IN HIGH-CURRENT DC RECTIFIERS [J].
OLIVIER, G ;
APRIL, GE ;
NGANDUI, E ;
GUIMARAES, C .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (01) :127-133
[10]  
Paice D.A., 1996, Power Electronic Converter Harmonics: Multipulse Methods for Clean Power