Risk of contamination of the wound in a hydrotherapeutic tank

被引:4
作者
Stanwood, W [1 ]
Pinzur, MS [1 ]
机构
[1] Loyola Univ, Med Ctr, Dept Orthopaed Surg, Stritch Sch Med, Maywood, IL 60153 USA
关键词
D O I
10.1177/107110079801900312
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Over a 4-week period, samples for culture were taken from active hydrotherapeutic tanks (whirlpools) from two institutions in a university medical center. Samples were obtained in the morning before treatments began, and in the evening after, the final patient had been treated. Specific attention was directed toward recovery of S. aureus, P. aeruginosa, and E. coli, organisms felt to be especially dangerous for the diabetic dysvascular patients utilizing the hydrotherapeutic tanks involved in this study. Only eleven of 96 cultures (11.5%) were positive for these prospective pathogens. Of the positive cultures, nine (9.4%) were taken from near the agitator-jet, and only two (2.1%) from the floor of the hydrotherapeutic tanks, where the extremity is likely to be placed. Our results reveal that hydrotherapeutic immersion is not likely to expose patients with open wounds to potential iatrogenic contamination of the wound.
引用
收藏
页码:173 / 176
页数:4
相关论文
共 6 条
[1]  
KOEPKE G H, 1965, Arch Phys Med Rehabil, V46, P261
[2]  
MANSELL RE, 1974, ARCH PHYS MED REHAB, V55, P318
[3]  
MANSELL RE, 1972, ARCH PHYS MED REHAB, V53, P439
[4]  
Miller J K, 1970, Phys Ther, V50, P1482
[5]  
PAGE C F, 1954, Arch Phys Med Rehabil, V35, P97
[6]   DISINFECTION OF IMMERSION TANKS (HUBBARD) IN A HOSPITAL BURN UNIT [J].
TURNER, AG ;
HIGGINS, MM ;
CRADDOCK, JG .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1974, 28 (02) :101-104