The influence of the levonorgestrel-releasing intrauterine system position on bleeding patterns in reproductive age women

被引:7
作者
Alves, Renata D. M. S. [1 ]
Rabelo, Maiara M. [1 ]
Andrade, Venandra R. [1 ]
Cabral, Renata C. S. [2 ]
Merriman, Joely W. [1 ,3 ]
Brito, Milena B. [1 ,2 ]
机构
[1] BSMPH, Dept Gynecol & Obstet, Salvador, BA, Brazil
[2] Univ Fed Bahia, Dept Gynecol & Obstet, Salvador, BA, Brazil
[3] Univ Rochester, Sch Med & Dent, Ctr Advocacy Community Hlth Educ & Divers, Rochester, NY USA
关键词
Bleeding; Contraception; Counseling; Intrauterine devices; Levonorgestrel-releasing IUS (intrauterine system); Long-acting reversible contraception; Position; Ultrasonography; DISCONTINUATION RATES; CONTRACEPTION; ULTRASOUND; FERTILITY; PAIN; IUD;
D O I
10.1002/ijgo.12962
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective To determine whether users of the non-fundal levonorgestrel-releasing intrauterine system (LNG-IUS) present with unfavorable bleeding patterns more frequently than fundal LNG-IUS users. Methods A prospective cohort was conducted from June, 2016 to January, 2018 involving women aged 18-45 years who wished to use the LNG-IUS as contraception and had no contraindications, endometrial polyps, submucosal myomas, irregular menstrual cycle, or anticoagulant use. Two study groups comprised women using fundal insertion and non-fundal insertion LNG-IUS. Bleeding was evaluated using a diary and pictogram chart. Results Of the 92 women who participated in the study, those with non-fundal LNG-IUS insertion sustained bleeding at rates greater than 83% (31) in the first 3 months of use, and 58% (14) at 6 months, versus 51% (22) at 3 months and 33% (19) at 6 months in those with fundal insertion (P=0.002 at 3 months; P=0.037 at 6 months). Blood loss in the non-fundal LNG-IUS group was higher than in the fundal LNG-IUS group according to pictograms drawn by participants. Conclusion Women with non-fundal LNG-IUS placement had a higher frequency of sustained bleeding and blood loss volume according to self-reported charts than those with fundal LNG-IUS placement.
引用
收藏
页码:326 / 331
页数:6
相关论文
共 21 条
[1]  
[Anonymous], 2015, Medical eligibility criteria for contraceptive use, V5th
[2]   THE ANALYSIS OF VAGINAL BLEEDING PATTERNS INDUCED BY FERTILITY REGULATING METHODS [J].
BELSEY, EM ;
MACHIN, D ;
DARCANGUES, C .
CONTRACEPTION, 1986, 34 (03) :253-260
[3]   Three-dimensional ultrasound detection of abnormally located intrauterine contraceptive devices which are a source of pelvic pain and abnormal bleeding [J].
Benacerraf, B. R. ;
Shipp, T. D. ;
Bromley, B. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 34 (01) :110-115
[4]   A multicentre, open-label, randomised phase III study comparing a new levonorgestrel intrauterine contraceptive system (LNG-IUS 8) with combined oral contraception in young women of reproductive age [J].
Borgatta, Lynn ;
Buhling, Kai J. ;
Rybowski, Sarah ;
Roth, Katrin ;
Rosen, Kimberly .
EUROPEAN JOURNAL OF CONTRACEPTION AND REPRODUCTIVE HEALTH CARE, 2016, 21 (05) :372-379
[5]   Blood copper levels in Mexican users of the T380A IUD [J].
De la Cruz, D ;
Cruz, A ;
Arteaga, M ;
Castillo, L ;
Tovalin, H .
CONTRACEPTION, 2005, 72 (02) :122-125
[6]   No relationship between the IUD position evaluated by ultrasound and complaints of bleeding and pain [J].
Faundes, D ;
Bahamondes, L ;
Faundes, A ;
Petta, C ;
Diaz, J ;
Marchi, N .
CONTRACEPTION, 1997, 56 (01) :43-47
[7]   Implantable contraceptives for women: effectiveness, discontinuation rates, return of fertility, and outcome of pregnancies [J].
Glasier, A .
CONTRACEPTION, 2002, 65 (01) :29-37
[8]  
Goncalves WJ, 1995, REPROD CLIM, V10, P63
[9]   Bleeding patterns and clinical performance of the levonorgestrel-releasing intrauterine system (Mirena) up to two years [J].
Hidalgo, M ;
Bahamondes, L ;
Perrotti, M ;
Diaz, J ;
Dantas-Monteiro, C ;
Petta, C .
CONTRACEPTION, 2002, 65 (02) :129-132
[10]  
Hurr W., 2009, Journal of College Student Psychotherapy, V25, P269, DOI DOI 10.1080/87568225.2011.581945