Influence of the manufacturing process in performance concerning wear of total hip prostheses

被引:2
|
作者
Oliveira, A. L. L. [1 ]
机构
[1] Univ Sao Paulo, Dept Mech Engn, BR-2231 Sao Paulo, Brazil
关键词
Total hip prostheses; Manufacturing process; Quality control; Roundness; Roughness; Tribology; MOLECULAR-WEIGHT POLYETHYLENE; BEARING SURFACE; ARTHROPLASTY; JOINTS; REPLACEMENTS; ROUGHNESS; CEMENT;
D O I
10.1007/s40430-013-0123-x
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wear on joint prostheses is the leading cause of premature failure leading to revision surgery. Tests conducted on mechanical wear simulator show poor performance of prosthetic hip components manufactured using high-quality raw materials. Aiming to understand the phenomena that limit the longevity of joint prostheses, the manufacturing processes of two separate companies were investigated. Results obtained suggest that the lack of control during the manufacturing of the parts may be the reason for the low performance shown by the prostheses tested in the wear simulator. Out-of-roundness and roughness of finished surfaces is pointed out as the main manufacturing failure in production lines tested. Metal femoral heads showed deviations from roundness of up to 32.41 lm (sigma = 8.869) and R-a = 0.295 +/- 0.03, while acetabular cups in ultra-high molecular weight polyethylene showed deviations of up to 166.31 mu m (sigma = 53.982) and R-a = 0.031 +/- 0.02. The out-of-roundness contributes to reducing the contact area between rolling surfaces, increasing tension in regions where premature wear on parts occurs with frequency. This study points out the common faults found in manufacturing processes and suggest changes to increase the longevity of total hip arthroplasty.
引用
收藏
页码:787 / 795
页数:9
相关论文
共 50 条
  • [41] Influence of liner offset and locking mechanism on fatigue durability in highly cross-linked polyethylene total hip prostheses
    Kamada, Kosuke
    Takahashi, Yasuhito
    Tateiwa, Toshiyuki
    Shishido, Takaaki
    Masaoka, Toshinori
    Pezzotti, Giuseppe
    Yamamoto, Kengo
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2020, 108 (05) : 1993 - 2004
  • [42] Observations at the articular surface of hip prostheses: An analytical electron microscopy study on wear and corrosion
    Koerten, HK
    Onderwater, JJM
    Koerten, EWA
    Bernoski, FP
    Nelissen, RGHH
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 54 (04): : 591 - 596
  • [43] Influence of structure isotropy of machined surface on the wear process
    Matuszewski, Maciej
    Mikolajczyk, Tadeusz
    Pimenov, Danil Yu.
    Styp-Rekowski, Michal
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2017, 88 (9-12) : 2477 - 2483
  • [44] Influence of structure isotropy of machined surface on the wear process
    Maciej Matuszewski
    Tadeusz Mikolajczyk
    Danil Yu. Pimenov
    Michal Styp-Rekowski
    The International Journal of Advanced Manufacturing Technology, 2017, 88 : 2477 - 2483
  • [45] Microscale wear behavior and crosslinking of PEG-like coatings for total hip replacements
    Kane, Sheryl R.
    Ashby, Paul D.
    Pruitt, Lisa A.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2010, 21 (04) : 1037 - 1045
  • [46] Tribology of total hip arthroplasty prostheses: what an orthopaedic surgeon should know
    Rieker, Claude B.
    EFORT OPEN REVIEWS, 2016, 1 (02): : 52 - 57
  • [47] Cemented, cementless, and hybrid prostheses for total hip replacement: cost effectiveness analysis
    Pennington, Mark
    Grieve, Richard
    Sekhon, Jasjeet S.
    Gregg, Paul
    Black, Nick
    van der Meulen, Jan H.
    BMJ-BRITISH MEDICAL JOURNAL, 2013, 346
  • [48] Polyethylene sterilization and production affects wear in total hip arthroplasties
    Faris, Philip M.
    Ritter, Merrill A.
    Pierce, Andrew L.
    Davis, Kenneth E.
    Faris, Gregory W.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) : 305 - 308
  • [49] Catastrophic wear in a metal-on-ceramic total hip arthroplasty
    Ramon Valenti, Juan
    Del Rio, Javier
    Amillo, Santiago
    JOURNAL OF ARTHROPLASTY, 2007, 22 (06) : 920 - 922
  • [50] Optimization of metal artefact reduction (MAR) sequences for MRI of total hip prostheses
    Toms, A. P.
    Smith-Bateman, C.
    Malcolm, P. N.
    Cahir, J.
    Graves, M.
    CLINICAL RADIOLOGY, 2010, 65 (06) : 447 - 452