Influence of the manufacturing process in performance concerning wear of total hip prostheses

被引:2
|
作者
Oliveira, A. L. L. [1 ]
机构
[1] Univ Sao Paulo, Dept Mech Engn, BR-2231 Sao Paulo, Brazil
关键词
Total hip prostheses; Manufacturing process; Quality control; Roundness; Roughness; Tribology; MOLECULAR-WEIGHT POLYETHYLENE; BEARING SURFACE; ARTHROPLASTY; JOINTS; REPLACEMENTS; ROUGHNESS; CEMENT;
D O I
10.1007/s40430-013-0123-x
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wear on joint prostheses is the leading cause of premature failure leading to revision surgery. Tests conducted on mechanical wear simulator show poor performance of prosthetic hip components manufactured using high-quality raw materials. Aiming to understand the phenomena that limit the longevity of joint prostheses, the manufacturing processes of two separate companies were investigated. Results obtained suggest that the lack of control during the manufacturing of the parts may be the reason for the low performance shown by the prostheses tested in the wear simulator. Out-of-roundness and roughness of finished surfaces is pointed out as the main manufacturing failure in production lines tested. Metal femoral heads showed deviations from roundness of up to 32.41 lm (sigma = 8.869) and R-a = 0.295 +/- 0.03, while acetabular cups in ultra-high molecular weight polyethylene showed deviations of up to 166.31 mu m (sigma = 53.982) and R-a = 0.031 +/- 0.02. The out-of-roundness contributes to reducing the contact area between rolling surfaces, increasing tension in regions where premature wear on parts occurs with frequency. This study points out the common faults found in manufacturing processes and suggest changes to increase the longevity of total hip arthroplasty.
引用
收藏
页码:787 / 795
页数:9
相关论文
共 50 条
  • [31] Survivorship of Total Hip Joint Replacements Following Isolated Liner Exchange for Wear
    Vadei, Leone
    Kieser, David C.
    Frampton, Chris
    Hooper, Gary
    JOURNAL OF ARTHROPLASTY, 2017, 32 (11) : 3484 - 3487
  • [32] How to measure wear following total hip arthroplasty
    Grillini, Laura
    Affatato, Saverio
    HIP INTERNATIONAL, 2013, 23 (03) : 233 - 242
  • [33] Progress in Wear Resistant Materials for Total Hip Arthroplasty
    Khanna, Rohit
    Ong, Joo L.
    Oral, Ebru
    Narayan, Roger J.
    COATINGS, 2017, 7 (07):
  • [34] Design Optimization of a Total Hip Prosthesis for Wear Reduction
    Matsoukas, George
    Kim, Il Yong
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (05):
  • [35] Survival rates for cemented Charnley total hip prostheses and influencing parameters
    Fuchs, S
    Wieder, J
    BIOMEDIZINISCHE TECHNIK, 2000, 45 (12): : 362 - 369
  • [36] Characterisation of the wear mechanisms in retrieved alumina-on-alumina total hip replacements
    Zeng, P.
    Rainforth, W. M.
    Stewart, T. D.
    WEAR, 2017, 376 : 212 - 222
  • [37] Probabilistic analysis of the influence of the bonding degree of the stem-cement interface in the performance of cemented hip prostheses
    Perez, M. A.
    Grasa, J.
    Garcia-Aznar, J. M.
    Bea, J. A.
    Doblare, M.
    JOURNAL OF BIOMECHANICS, 2006, 39 (10) : 1859 - 1872
  • [38] Rehabilitation Process Issues and Functional Performance after Total Hip and Knee Replacement
    Fedonnikov, Alexander S.
    Andriyanova, Elena A.
    Kiselev, Anton R.
    Norkin, Igor A.
    HEALTHCARE, 2021, 9 (09)
  • [39] Monitoring surgical performance: an application to total hip replacement
    Biau, David J.
    Milet, Alexandre
    Thevenin, Fabrice
    Anract, Philippe
    Porcher, Raphael
    JOURNAL OF EVALUATION IN CLINICAL PRACTICE, 2009, 15 (03) : 420 - 424
  • [40] Influence of Metallic Deposition on Ceramic Femoral Heads on the Wear Behavior of Artificial Hip Joints: A Simulator Study
    Hembus, Jessica
    Roessler, Lisa
    Jackszis, Mario
    Klinder, Annett
    Bader, Rainer
    Zietz, Carmen
    MATERIALS, 2020, 13 (16)