Influence of the manufacturing process in performance concerning wear of total hip prostheses

被引:2
|
作者
Oliveira, A. L. L. [1 ]
机构
[1] Univ Sao Paulo, Dept Mech Engn, BR-2231 Sao Paulo, Brazil
关键词
Total hip prostheses; Manufacturing process; Quality control; Roundness; Roughness; Tribology; MOLECULAR-WEIGHT POLYETHYLENE; BEARING SURFACE; ARTHROPLASTY; JOINTS; REPLACEMENTS; ROUGHNESS; CEMENT;
D O I
10.1007/s40430-013-0123-x
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wear on joint prostheses is the leading cause of premature failure leading to revision surgery. Tests conducted on mechanical wear simulator show poor performance of prosthetic hip components manufactured using high-quality raw materials. Aiming to understand the phenomena that limit the longevity of joint prostheses, the manufacturing processes of two separate companies were investigated. Results obtained suggest that the lack of control during the manufacturing of the parts may be the reason for the low performance shown by the prostheses tested in the wear simulator. Out-of-roundness and roughness of finished surfaces is pointed out as the main manufacturing failure in production lines tested. Metal femoral heads showed deviations from roundness of up to 32.41 lm (sigma = 8.869) and R-a = 0.295 +/- 0.03, while acetabular cups in ultra-high molecular weight polyethylene showed deviations of up to 166.31 mu m (sigma = 53.982) and R-a = 0.031 +/- 0.02. The out-of-roundness contributes to reducing the contact area between rolling surfaces, increasing tension in regions where premature wear on parts occurs with frequency. This study points out the common faults found in manufacturing processes and suggest changes to increase the longevity of total hip arthroplasty.
引用
收藏
页码:787 / 795
页数:9
相关论文
共 50 条
  • [21] Effect of head size on wear properties of metal-on-metal bearings of hip prostheses, and comparison with wear properties of metal-on-polyethylene bearings using hip simulator
    Okazaki, Yoshimitsu
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 31 : 152 - 163
  • [22] The Relative Merits of Cemented and Uncemented Prostheses in Total Hip Arthroplasty
    Joanna Maggs
    Matthew Wilson
    Indian Journal of Orthopaedics, 2017, 51 : 377 - 385
  • [23] Wear Performance of Ceramic-On-Metal Hip Bearings
    Reinders, Joern
    Sonntag, Robert
    Heisel, Christian
    Reiner, Tobias
    Vot, Leo
    Kretzer, Jan Philippe
    PLOS ONE, 2013, 8 (08):
  • [24] Influence of cup orientation on the wear performance of metal-on-metal hip replacements
    Angadji, A.
    Royle, M.
    Collins, S. N.
    Shelton, J. C.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H4) : 449 - 457
  • [25] LOW IN VITRO THIRD-BODY WEAR ON TOTAL HIP PROSTHESES INDUCED BY CALCIUM SULPHATE USED FOR LOCAL ANTIBIOTIC THERAPY
    Heuberger, R.
    Wahl, P.
    Krieg, J.
    Gautier, E.
    EUROPEAN CELLS & MATERIALS, 2014, 28 : 246 - 257
  • [26] Influence of Crosslinking on the Wear Performance of Polyethylene Within Total Ankle Arthroplasty
    Bischoff, Jeffrey E.
    Fryman, J. Craig
    Parcell, Jerry
    Villasenor, Diego A. Orozco
    FOOT & ANKLE INTERNATIONAL, 2015, 36 (04) : 369 - 376
  • [27] Wear-pattern analysis in retrieved tibial inserts of mobile-bearing and fixed-bearing total knee prostheses
    Lu, Y. -C.
    Huang, C. -H.
    Chang, T. -K.
    Ho, F. -Y.
    Cheng, C. -K.
    Huang, C. -H.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (04): : 500 - 507
  • [28] The Computational Approach to Predicting Wear: Comparison of Wear Performance of CFR-PEEK and XLPE Liners in Total Hip Replacement
    Alpkaya, Alican Tuncay
    Mihcin, Senay
    TRIBOLOGY TRANSACTIONS, 2023, 66 (01) : 59 - 72
  • [29] Volumetric wear assessment of failed metal-on-metal hip resurfacing prostheses
    Lord, J. K.
    Langton, D. J.
    Nargol, A. V. F.
    Joyce, T. J.
    WEAR, 2011, 272 (01) : 79 - 87
  • [30] A dynamic model of polyethylene damage in dry total hip arthroplasties: wear and creep
    Askari, Ehsan
    Andersen, Michael S.
    MULTIBODY SYSTEM DYNAMICS, 2019, 45 (04) : 403 - 429