Effectiveness of Prolonged Air-Recuring on Strength of Fire Damaged RC Columns

被引:4
作者
Ehsan, M. Adeel [1 ]
Yaqub, M. [1 ]
Khan, M. Uzair [1 ]
Amir, M. U. A. R. [1 ]
Hussain, Iqrar [1 ]
机构
[1] Univ Engn & Technol Taxila, Dept Civil Engn, Rawalpindi 47080, Punjab North, Pakistan
来源
CIVIL ENGINEERING JOURNAL-TEHRAN | 2019年 / 5卷 / 10期
关键词
Fire Damaged; Modelling Temperature Levels; Prolonged Air-Recuring; Steel Wire Mesh; Epoxy Injection and Epoxy Resin Mortar Filling; Carbon Fibre Reinforced Polymer and Compressive Strength; CONCRETE;
D O I
10.28991/cej-2019-03091405
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, the effect of post-fire prolonged air-recuring on the recovery of strength of reinforced concrete was investigated after exposing to elevated temperature levels varying from 300 degrees C to 900 degrees C. The main objective of the paper is to find the effectiveness of prolonged air-recuring on strength of fire damaged RC columns. In order to achieve this, a total of 24 reinforced concrete circular columns having size (sic) 200x1200 mm were casted and tested under compressive loading. Eighteen specimens were heated in an electric furnace such that six specimens at each temperature level i.e. 300 degrees C, 500 degrees C and 900 degrees C. After heating, specimens were allowed to cool down naturally at ambient temperature and then specimens were air-recured in open environment (high humidity) following by repairing of respective specimens with various confinement techniques. After post fire prolonged air-recuring, test results showed that decrease in axial compressive at all temperature levels was less compared to values reported in literature for corresponding temperatures. This confirms the recovery of microstructure and thus increase in strength of post heated reinforced concrete circular columns due to prolonged air-recuring. It has been observed that both the confinement techniques i.e. single layer of CFRP only and epoxy injection, steel wire mesh filled with epoxy resin mortar along with CFRP wrapping restored the original strength or even more of air-recured post heated reinforced concrete circular columns compared to that of un-heated control specimens or even more.
引用
收藏
页码:2207 / 2220
页数:14
相关论文
共 18 条
[1]   Energy approach in peformance-based seismic design of steel moment resisting frames for basic safety objective [J].
Akbas, B ;
Shen, J ;
Hao, H .
STRUCTURAL DESIGN OF TALL BUILDINGS, 2001, 10 (03) :193-217
[2]   Strength model for heat-damaged reinforced concrete circular columns confined with carbon fibre reinforced polymer fabrics [J].
Al-Kamaki, Yaman S. S. ;
Al-Mahaidi, Riadh ;
Bennetts, Ian .
JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2015, 34 (22) :1833-1855
[3]   Effectiveness of advanced composites in repairing heat-damaged RC columns [J].
Al-Nimry, Hanan ;
Haddad, Rami ;
Afram, Saad ;
Abdel-Halim, Mohammed .
MATERIALS AND STRUCTURES, 2013, 46 (11) :1843-1860
[4]   A study on different techniques of restoration of fire damaged reinforced concrete flexural members [J].
Bastin, Danie Roy Anasco ;
Sharma, Umesh Kumar .
Journal of Structural Fire Engineering, 2017, 8 (02) :131-148
[5]   Strengthening fire-damaged concrete by confinement with fibre-reinforced polymer wraps [J].
Bisby, L. A. ;
Chen, J. F. ;
Li, S. Q. ;
Stratford, T. J. ;
Cueva, N. ;
Crossling, K. .
ENGINEERING STRUCTURES, 2011, 33 (12) :3381-3391
[6]   Compressive behavior of steel fiber reinforced recycled aggregate concrete after exposure to elevated temperatures [J].
Chen, G. M. ;
He, Y. H. ;
Yang, H. ;
Chen, J. F. ;
Guo, Y. C. .
CONSTRUCTION AND BUILDING MATERIALS, 2014, 71 :1-15
[7]   Effects of Elevated Temperatures on the Compressive Strength Capacity of Concrete Cylinders Confined with FRP Sheets: An Experimental Investigation [J].
El-Gamal, Sherif ;
Al-Jabri, Khalifa ;
Al-Mahri, Ahmed ;
Al-Mahrouqi, Saud .
INTERNATIONAL JOURNAL OF POLYMER SCIENCE, 2015, 2015
[8]   Effect of high temperature on structural response of reinforced concrete circular columns strengthened with fiber reinforced polymer composites [J].
Elsanadedy, Hussein ;
Almusallam, Tarek ;
Al-Salloum, Yousef ;
Iqbal, Rizwan .
JOURNAL OF COMPOSITE MATERIALS, 2017, 51 (03) :333-355
[9]   Strengthening and shape modification of fire-damaged concrete with expansive cement concrete and CFRP wrap [J].
Hosseinpour, M. ;
Celikag, M. ;
Bengar, H. Akbarzadeh .
SCIENTIA IRANICA, 2019, 26 (02) :699-708
[10]   Effects of sustained axial load and cooling phase on post-fire behaviour of concrete-filled steel tubular stub columns [J].
Huo, Jingsi ;
Huang, Guowang ;
Xiao, Yan .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (8-9) :1664-1676