Factors impacting accurate Cole-impedance extractions from magnitude-only measurements

被引:0
作者
Freeborn, Todd J. [1 ]
Elwakil, Ahmed [2 ]
Maundy, Brent [3 ]
机构
[1] Univ Alabama, Dept Elect Comp Engn, Tuscaloosa, AL 35487 USA
[2] Univ Sharjah, Dept Elect Comp Engn, Sharjah, U Arab Emirates
[3] Univ Calgary, Dept Elect Comp Engn, Calgary, AB, Canada
来源
2016 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC) | 2016年
关键词
LOCALIZED BIOIMPEDANCE; PARAMETERS; MUSCLE; MODEL;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The Cole impedance model is widely used in applications involving the electrical impedance of biological tissues. Typically requiring post-processing to determine its four parameters from electrical impedance measurements. Here, a non-linear least squares optimization routine is applied to extract the Cole impedance parameters from collected magnitude responses (not requiring direct impedance measurements). The aim is to quantify the impact of the measured frequency range, number of collected datapoints, and level of noise in the magnitude-only measurements on the accuracy of the extracted parameters. Further investigating the impact the optimization settings have on the accuracy and time required to extract the parameters. The aim is to understand these factors' effects towards the implementation of embedded systems utilizing this method to extract the impedance parameters.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 14 条
[1]  
[Anonymous], BIOIMPEDANCE BIOELEC
[2]  
[Anonymous], 1999, FRACTIONAL DIFFERENT
[3]   SIMPLE WIDE FREQUENCY RANGE IMPEDANCE METER BASED ON AD5933 INTEGRATED CIRCUIT [J].
Chabowski, Konrad ;
Piasecki, Tomasz ;
Dzierka, Andrzej ;
Nitsch, Karol .
METROLOGY AND MEASUREMENT SYSTEMS, 2015, 22 (01) :13-24
[4]   Cleaner quality control system using bioimpedance methods: a review for fruits and vegetables [J].
El Khaled, D. ;
Castellano, N. N. ;
Gazquez, J. A. ;
Garcia Salvador, R. M. ;
Manzano-Agugliaro, F. .
JOURNAL OF CLEANER PRODUCTION, 2017, 140 :1749-1762
[5]   Extracting the Cole-Cole impedance model parameters without direct impedance measurement [J].
Elwakil, A. S. ;
Maundy, B. .
ELECTRONICS LETTERS, 2010, 46 (20) :1367-1368
[6]   Extracting the parameters of the double-dispersion Cole bioimpedance model from magnitude response measurements [J].
Freeborn, Todd J. ;
Maundy, Brent ;
Elwakil, Ahmed S. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (09) :749-758
[7]   A Survey of Fractional-Order Circuit Models for Biology and Biomedicine [J].
Freeborn, Todd J. .
IEEE JOURNAL ON EMERGING AND SELECTED TOPICS IN CIRCUITS AND SYSTEMS, 2013, 3 (03) :416-424
[8]   Extraction of Cole parameters from the electrical bioimpedance spectrum using stochastic optimization algorithms [J].
Gholami-Boroujeny, Shiva ;
Bolic, Miodrag .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (04) :643-651
[9]   Bioimpedance system for monitoring muscle and cardiovascular activity in the stump of lower-limb amputees [J].
Hornero, G. ;
Diaz, D. ;
Casas, O. .
PHYSIOLOGICAL MEASUREMENT, 2013, 34 (02) :189-201
[10]   A four-electrode low frequency impedance spectroscopy measurement system using the AD5933 measurement chip [J].
Margo, C. ;
Katrib, J. ;
Nadi, M. ;
Rouane, A. .
PHYSIOLOGICAL MEASUREMENT, 2013, 34 (04) :391-405