FE analysis of the effects of simplifications in experimental testing on micromotions of uncemented femoral knee implants

被引:19
作者
Berahmani, Sanaz [1 ]
Janssen, Dennis [1 ]
Wolfson, David [2 ]
Malefijt, Maarten de Waal [3 ]
Fitzpatrick, Clare K. [4 ]
Rullkoetter, Paul J. [4 ]
Verdonschot, Nico [1 ,5 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Radboud Inst Hlth Sci, Orthopaed Res Lab, POB 9101, NL-6500 HB Nijmegen, Netherlands
[2] DePuy Synthes Joint Reconstruct, Leeds LS11 0BG, W Yorkshire, England
[3] Radboud Univ Nijmegen, Dept Orthopaed, Radboud Inst Hlth Sci, Med Ctr, POB 9101, NL-6500 HB Nijmegen, Netherlands
[4] Univ Denver, Ctr Orthopaed Biomech, 2390 S York St, Denver, CO 80208 USA
[5] Univ Twente, Lab Biomech Engn, POB 217, NL-7500 AE Enschede, Netherlands
关键词
uncemented total knee replacement; micromotions; finite element analysis; physiological loading; primary stability; IN-VITRO; LOADING CONDITIONS; PRIMARY STABILITY; PRIMARY FIXATION; BONE FIXATION; REPLACEMENT; COMPONENT; INTERFACE; SURFACE; STEM;
D O I
10.1002/jor.23074
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Experimental testing of orthopaedic implants requires simplifications concerning load application and activities being analyzed. This computational study investigated how these simplifications affect micromotions at the bone-implant interface of an uncemented femoral knee implant. As a basis, validated in vivo loads of the stance phase of gait and a deep knee bend were adopted. Eventually, three configurations were considered: (i) simulation of the complete loading cycle; (ii) inclusion of only tibiofemoral loads (ignoring patellofemoral loads); and (iii) applying only a single peak tibiofemoral force. For all loading conditions the largest micromotions found at the proximal anterior flange. Without the patellofemoral force, peak micromotions increased 6% and 22% for gait and deep knee bend, respectively. By applying a single peak tibiofemoral force micromotions were overestimated. However, the peak micromotions corresponded to the maximum tibiofemoral force, and strong micromotion correlations were found between a complete loading cycle and a single peak load (R-2=0.73 and R-2=0.89 for gait and deep knee bend, respectively). Deep knee bend resulted in larger micromotions than gait. Our study suggests that a simplified peak force can be used to assess the stability of cementless femoral components. For more robust testing, implants should be subjected to different loading modes. (c) 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:812-819, 2016.
引用
收藏
页码:812 / 819
页数:8
相关论文
共 35 条
[1]   Finite element modelling of primary hip stem stability: The effect of interference fit [J].
Abdul-Kadir, Mohammed Rafiq ;
Hansen, Ulrich ;
Klabunde, Ralf ;
Lucas, Duncan ;
Amis, Andrew .
JOURNAL OF BIOMECHANICS, 2008, 41 (03) :587-594
[2]   On the influence of shape and material used for the femoral component pegs in knee prostheses for reducing the problem of aseptic loosening [J].
Bahraminasab, Marjan ;
Sahari, B. B. ;
Edwards, K. L. ;
Farahmand, Farzam ;
Jahan, Ali ;
Hong, Tang Sai ;
Arumugam, Manohar .
MATERIALS & DESIGN, 2014, 55 :416-428
[3]   Aseptic loosening of femoral components - A review of current and future trends in materials used [J].
Bahraminasab, Marjan ;
Sahari, B. B. ;
Edwards, K. L. ;
Farahmand, Farzam ;
Arumugam, Manohar ;
Hong, Tang Sai .
MATERIALS & DESIGN, 2012, 42 :459-470
[4]   The Effect of Surface Morphology on the Primary Fixation Strength of Uncemented Femoral Knee Prosthesis: A Cadaveric Study [J].
Berahmani, Sanaz ;
Janssen, Dennis ;
Wolfson, David ;
Rivard, Kori ;
Malefijt, Maarten de Waal ;
Verdonschot, Nico .
JOURNAL OF ARTHROPLASTY, 2015, 30 (02) :300-307
[5]   Micromotion of Cementless Tibial Baseplates Under Physiological Loading Conditions [J].
Bhimji, Safia ;
Meneghini, R. Michael .
JOURNAL OF ARTHROPLASTY, 2012, 27 (04) :648-654
[6]   Time-dependent fixation and implantation forces for a femoral knee component-An in vitro study [J].
Burgers, Travis ;
Mason, Jim ;
Squire, Matthew ;
Ploeg, Heidi-Lynn .
MEDICAL ENGINEERING & PHYSICS, 2010, 32 (09) :968-973
[7]   Analysis of bone-prosthesis interface micromotion for cementless tibial prosthesis fixation and the influence of loading conditions [J].
Chong, Desmond Y. R. ;
Hansen, Ulrich N. ;
Amis, Andrew A. .
JOURNAL OF BIOMECHANICS, 2010, 43 (06) :1074-1080
[8]   The influence of stem length and fixation on initial femoral component stability in revision total knee replacement [J].
Conlisk, N. ;
Gray, H. ;
Pankaj, P. ;
Howie, C. R. .
BONE & JOINT RESEARCH, 2012, 1 (11) :281-288
[9]   Long-term implant-bone fixation of the femoral component in total knee replacement [J].
Cristofolini, L. ;
Affatato, S. ;
Erani, P. ;
Leardini, W. ;
Tigani, D. ;
Viceconti, M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H3) :319-331
[10]  
Cristofolini L, 2007, P I MECH ENG H, V221, P943, DOI 10.1243/09544119JE1M278