The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis

被引:82
作者
Eraslan, Oguz [1 ]
Inan, Oezguer [1 ]
机构
[1] Univ Selcuk, Fac Dent, Dept Prosthodont, Konya, Turkey
关键词
Implant thread form design; Dental implants; Biomechanics; Finite element analysis; Stress distribution; BONE INTERFACE CHARACTERISTICS; DENTAL IMPLANTS;
D O I
10.1007/s00784-009-0305-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The biomechanical behavior of implant thread plays an important role on stresses at implant-bone interface. Information about the effect of different thread profiles upon the bone stresses is limited. The purpose of this study was to evaluate the effects of different implant thread designs on stress distribution characteristics at supporting structures. In this study, three-dimensional (3D) finite element (FE) stress-analysis method was used. Four types of 3D mathematical models simulating four different thread-form configurations for a solid screw implant was prepared with supporting bone structure. V-thread (1), buttress (2), reverse buttress (3), and square thread designs were simulated. A 100-N static axial occlusal load was applied to occlusal surface of abutment to calculate the stress distributions. Solidworks/Cosmosworks structural analysis programs were used for FE modeling/analysis. The analysis of the von Mises stress values revealed that maximum stress concentrations were located at loading areas of implant abutments and cervical cortical bone regions for all models. Stress concentration at cortical bone (18.3 MPa) was higher than spongious bone (13.3 MPa), and concentration of first thread (18 MPa) was higher than other threads (13.3 MPa). It was seen that, while the von Mises stress distribution patterns at different implant thread models were similar, the concentration of compressive stresses were different. The present study showed that the use of different thread form designs did not affect the von Mises concentration at supporting bone structure. However, the compressive stress concentrations differ by various thread profiles.
引用
收藏
页码:411 / 416
页数:6
相关论文
共 26 条
[1]  
Beer FP, 2005, MECH MATER, V4th, P360
[2]  
Brunski J B, 1999, Adv Dent Res, V13, P99
[3]   A FINITE-ELEMENT ANALYSIS OF THE HUMAN TEMPOROMANDIBULAR-JOINT [J].
CHEN, J ;
XU, LF .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (04) :401-407
[4]   Evaluation of design parameters of osseointegrated dental implants using finite element analysis [J].
Chun, HJ ;
Cheong, SY ;
Han, JH ;
Heo, SJ ;
Chung, JP ;
Rhyu, IC ;
Choi, YC ;
Baik, HK ;
Ku, Y ;
Kim, MH .
JOURNAL OF ORAL REHABILITATION, 2002, 29 (06) :565-574
[5]   A MODEL FOR THE IMPLANT-BONE INTERFACE CHARACTERISTICS OF POROUS DENTAL IMPLANTS [J].
COOK, SD ;
KLAWITTER, JJ ;
WEINSTEIN, AM .
JOURNAL OF DENTAL RESEARCH, 1982, 61 (08) :1006-1009
[6]  
Cruz M, 2003, INT J ORAL MAX IMPL, V18, P675
[7]   Finite element analysis of four thread-form configurations in a stepped screw implant [J].
Geng, JP ;
Ma, QS ;
Xu, W ;
Tan, KBC ;
Liu, GR .
JOURNAL OF ORAL REHABILITATION, 2004, 31 (03) :233-239
[8]  
Geng JP, 1995, SHANGHAI SHENGWU GON, V50, P19
[9]   The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study [J].
Hansson, S ;
Werke, M .
JOURNAL OF BIOMECHANICS, 2003, 36 (09) :1247-1258
[10]  
Ivanoff CJ, 1999, INT J ORAL MAX IMPL, V14, P173