A rapid screening LC-MS/MS method based on conventional HPLC pumps for the analysis of low molecular weight xenobiotics: application to doping control analysis

被引:18
作者
Mazzarino, Monica [1 ]
de la Torre, Xavier [2 ]
Botre, Francesco [1 ,3 ]
Gray, Nicola [1 ,2 ]
Cowan, David [2 ]
机构
[1] Antidoping Lab Rome, I-00197 Rome, Italy
[2] Kings Coll London, Drug Control Ctr, London SE1 9NH, England
[3] Univ Roma La Sapienza, Dipartimento Tecnol & Management, I-00161 Rome, Italy
关键词
fused-core particle columns; LC-MS/MS; anti-doping analysis; xenobiotics; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; HUMAN URINE; ANABOLIC-STEROIDS; DIURETICS; STIMULANTS; UPLC; GLUCOCORTICOIDS; TEMPERATURE; EFFICIENCY;
D O I
10.1002/dta.148
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study presents a fast multi-analyte screening method specifically developed for the detection of xenobiotics in urine. The proposed method allows the screening of several classes of substance in a single chromatographic method with a run-time of 11 min, inclusive of post-run and reconditioning times. Chromatographic separation is achieved in 7.2 min using a reversed-phase 2.7 mu m fused-core particle column, generating a back-pressure not exceeding 400 bar and therefore enabling the use of traditional high performance liquid chromatography (HPLC) instruments. The effectiveness of this approach was evaluated, by liquid-chromatography tandem mass spectrometry (LC-MS/MS) in positive electrospray ionization, using 20 blank urine samples spiked with 45 compounds prohibited in sport: 11 diuretics, 16 glucocorticoids, 9 stimulants, 5 anti-oestrogens, as well as formoterol, carboxy-finasteride (previously prohibited by the World Anti-Doping Agency (WADA) in 2008), gestrinone and tetrahydrogestrinone. Qualitative validation shows the proposed method to be specific with no significant interference. All of the analytes considered in this study were clearly distinguishable in urine, with limits of detection ranging from 5 ng/mL to 350 ng/mL, significantly below the Minimum Required Performance Levels (MRPL) set by WADA for the accredited sports anti-doping laboratories. All compounds of interest were separated, including synthetic and endogenous glucocorticoids with similar retention times and fragmentation patterns. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:311 / 322
页数:12
相关论文
共 26 条
  • [1] HIGH-SPEED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PEPTIDES AND PROTEINS
    CHEN, H
    HORVATH, C
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (01) : 3 - 20
  • [2] Improving LC-MS sensitivity through increases in chromatographic performance: Comparisons of UPLC-ES/MS/MS to HPLC-ES/MS/MS
    Churchwell, MI
    Twaddle, NC
    Meeker, LR
    Doerge, DR
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 825 (02): : 134 - 143
  • [3] Fused-core particle technology as an alternative to sub-2-αm particles to achieve high separation efficiency with low backpressure
    Cunliffe, Jennifer M.
    Maloney, Todd D.
    [J]. JOURNAL OF SEPARATION SCIENCE, 2007, 30 (18) : 3104 - 3109
  • [4] Evaluation of ultra performance liquid chromatography -: Part I.: Possibilities and limitations
    de Villiers, Andre
    Lestremau, Francois
    Szucs, Roman
    Gelebart, Sylvie
    David, Frank
    Sandra, Pat
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) : 60 - 69
  • [5] Simultaneous determination of beta-blocking agents and diuretics in doping analysis by liquid chromatography mass spectrometry with scan-to-scan polarity switching
    Deventer, K
    Van Eenoo, P
    Delbeke, FT
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (02) : 90 - 98
  • [6] Screening for 18 diuretics and probenecid in doping analysis by liquid chromatography-tandem mass spectrometry
    Deventer, K
    Delbeke, FT
    Roels, K
    Van Eenoo, P
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2002, 16 (08) : 529 - 535
  • [7] DEVENTER K, 2003, RECENT ADV DOPING AN, V11, P23
  • [8] FOURACRE C, 2001, RECENT ADV DOPING AN, V9, P321
  • [9] Rapid screening method for diuretics in doping control using automated solid phase extraction and liquid chromatography-electrospray tandem mass spectrometry
    Goebel, C
    Trout, GJ
    Kazlauskas, R
    [J]. ANALYTICA CHIMICA ACTA, 2004, 502 (01) : 65 - 74
  • [10] GOEBEL C, 2006, RECENT ADV DOPING AN, V14, P47