Second and first trimester estimation of risk for Down syndrome: implementation and performance in the SAFER study

被引:7
|
作者
MacRae, Andrew R. [1 ]
Chodirker, Bernie N. [1 ]
Davies, Gregory A. [2 ]
Palomaki, Glenn E. [3 ]
Knight, George J. [3 ]
Minett, Jane
Kavsak, Peter A. [4 ]
Toi, Ants [5 ]
Chitayat, David [6 ]
Van Caeseele, Paul G. [7 ]
机构
[1] Univ Manitoba, Biochem & Med Genet, Winnipeg, MB, Canada
[2] Queens Univ, Obstet & Gynecol, Kingston, ON, Canada
[3] Brown Univ, Women & Infants Hosp, Lab Med, Providence, RI USA
[4] McMaster Univ, Pathol & Mol Med, Hamilton, ON, Canada
[5] Univ Toronto, Mt Sinai Hosp, Diagnost Imaging, Toronto, ON M5S 1A1, Canada
[6] Univ Toronto, Mt Sinai Hosp, Prenatal Diag & Med Genet Program, Toronto, ON M5S 1A1, Canada
[7] Univ Manitoba, Med Microbiol, Winnipeg, MB, Canada
关键词
Down syndrome; prenatal screening; serum markers; nuchal translucency; risk algorithms; SERUM ALPHA-FETOPROTEIN; MATERNAL SERUM; ULTRASOUND; 1ST-TRIMESTER; AGE; PREGNANCIES; TRISOMY-21; INHIBIN; SURUSS; TESTS;
D O I
10.1002/pd.2502
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
Objectives Document patient choices and screening performance (false positive and detection rates) when three improved Down syndrome screening protocols were introduced coincidentally. Method Second-trimester 'triple marker' screening was expanded by adding second-trimester dimeric inhibin-A (four-marker), with or without first-trimester pregnancy-associated plasma protein-A (five-marker). Nuchal translucency (NT) measurements were included when available from accredited sonographers (six-marker). For assigning risk, two sets of marker distribution parameters were evaluated. Results Over 3.5 years, 8571 women enrolled (median age 30.6 years). Uptake of the four-, five- and six-marker protocols was 18%, 46% and 36%, respectively. Of those selecting an integrated test (five or six markers), 9.7% did not provide the second trimester serum sample. False positive rates decreased with added markers (5.2%, 5.1% and 2.5%, respectively) and varied between the two parameter sets, while detection remained high. Overall, 21 of 23 cases were detected (91%, 95% CI 73-98%) at a 4.2% false positive rate (95% CI 3.3-5.1%). Conclusions Integrated screening protocols were chosen 4.6 times more often than four-marker screening (82% vs. 18% uptake). Overall detection was higher and false positives lower, consistent with recent guidelines. Important performance factors include gestational dating method, risk cut-off, and the parameter set used to assign risk. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:459 / 466
页数:8
相关论文
共 50 条
  • [1] Bedside estimation of Down syndrome risk from second-trimester ultrasound prenasal thickness
    Maymon, R.
    Moskovitch, M.
    Levinsohn-Tavor, O.
    Weinraub, Z.
    Herman, A.
    Cuckle, H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 34 (06) : 629 - 633
  • [2] Contingent screening for Down syndrome completed in the first trimester: a multicenter study
    Munoz-Cortes, M.
    Arigita, M.
    Falguera, G.
    Seres, A.
    Guix, D.
    Baldrich, E.
    Acera, A.
    Torrent, A.
    Rodriguez-Veret, A.
    Lopez-Quesada, E.
    Garcia-Moreno, R.
    Gonce, A.
    Borobio, V.
    Borrell, A.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 39 (04) : 396 - 400
  • [3] Bedside estimation of Down syndrome risk during first-trimester ultrasound screening
    Herman, A
    Dreazen, E
    Herman, AM
    Batukan, CEM
    Holzgreve, W
    Tercanli, S
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2002, 20 (05) : 468 - 475
  • [4] First trimester Down syndrome screening: Public health implications
    Fuchs, KM
    Peipert, JF
    SEMINARS IN PERINATOLOGY, 2005, 29 (04) : 267 - 271
  • [5] Inaccurate estimation of risk in second trimester serum screening for Down syndrome among women who have already had first trimester screening
    Hackshaw, AK
    Wald, NJ
    PRENATAL DIAGNOSIS, 2001, 21 (09) : 741 - 746
  • [6] Expected performance of second trimester maternal serum testing followed by a 'genetic sonogram' in screening of fetal Down syndrome
    Benn, Peter A.
    Egan, James F. X.
    PRENATAL DIAGNOSIS, 2008, 28 (03) : 230 - 235
  • [7] Comparison and integration of first trimester fetal nuchal translucency and second trimester maternal serum screening for fetal Down syndrome
    Lam, YH
    Lee, CP
    Sin, SY
    Tang, R
    Wong, HS
    Wong, SF
    Fong, DYT
    Tang, MHY
    Woo, HHN
    PRENATAL DIAGNOSIS, 2002, 22 (08) : 730 - 735
  • [8] Korean-Specific Parameter Models for Calculating the Risk of Down Syndrome in the Second Trimester of Pregnancy
    Kwon, Ji Young
    Park, In Yang
    Park, Yong Gue
    Lee, Young
    Lee, Guisera
    Shin, Jong Chul
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2011, 26 (12) : 1619 - 1624
  • [9] Second trimester prenatal ultrasound for the detection of pregnancies at increased risk of Down syndrome
    Smith-Bindman, Rebecca
    Chu, Philip
    Goldberg, James D.
    PRENATAL DIAGNOSIS, 2007, 27 (06) : 535 - 544
  • [10] Screening for Down syndrome using first-trimester ultrasound and second-trimester maternal serum markers in a low-risk population: a prospective longitudinal study
    Audibert, F
    Dommergues, M
    Benattar, C
    Taieb, J
    Thalabard, JC
    Frydman, R
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 18 (01) : 26 - 31