Absolute cerebral blood flow and blood volume measured by magnetic resonance imaging bolus tracking: Comparison with positron emission tomography values

被引:150
作者
Ostergaard, L
Smith, DF
Vestergaard-Poulsen, P
Hansen, SB
Gee, AD
Gjedde, A
Gyldensted, C
机构
[1] Aarhus Univ Hosp, Dept Neuroradiol, DK-8000 Aarhus, Denmark
[2] Aarhus Univ Hosp, Dept Biomed Engn, DK-8000 Aarhus, Denmark
[3] Aarhus Univ Hosp, Hosp Psychiat, DK-8000 Aarhus, Denmark
[4] Aarhus Univ Hosp, PET Ctr, DK-8000 Aarhus, Denmark
关键词
animal studies; cerebral blood flow; cerebral blood volume; hypercapnia; magnetic resonance imaging; positron emission tomography;
D O I
10.1097/00004647-199804000-00011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The authors determined cerebral blood flow (CBF) with magnetic resonance imaging (MRI) of contrast agent bolus passage and compared the results with those obtained by O-15 labeled water ((H2O)-O-15) and positron emission tomography (PET). Six pigs were examined by MRI and PET under normo- and hypercapnic conditions. After dose normalization and introduction of an empirical constant Phi(Gd), absolute regional CBF was calculated from MRI. The spatial resolution and the signal-to-noise ratio of CBF measurements by MRI were better than by the (H2O)-O-15-PET protocol. Magnetic resonance imaging cerebral blood volume (CBV) estimates obtained using this normalization constant correlated well with values obtained by O-15 labeled carbonmonooxide ((CO)-O-15) PET. However, PET CBV values were approximately 2.5 times larger than absolute MRI CBV values, supporting the hypothesized sensitivity of MRI to small vessels.
引用
收藏
页码:425 / 432
页数:8
相关论文
共 17 条
[1]   CEREBRAL BLOOD-VOLUME MAPS OF GLIOMAS - COMPARISON WITH TUMOR GRADE AND HISTOLOGIC-FINDINGS [J].
ARONEN, HJ ;
GAZIT, IE ;
LOUIS, DN ;
BUCHBINDER, BR ;
PARDO, FS ;
WEISSKOFF, RM ;
HARSH, GR ;
COSGROVE, GR ;
HALPERN, EF ;
HOCHBERG, FH ;
ROSEN, BR .
RADIOLOGY, 1994, 191 (01) :41-51
[2]   EFFECTS OF CHANGES IN PACO2 ON CEREBRAL BLOOD VOLUME, BLOOD FLOW, AND VASCULAR MEAN TRANSIT TIME [J].
GRUBB, RL ;
RAICHLE, ME ;
EICHLING, JO ;
TERPOGOS.MM .
STROKE, 1974, 5 (05) :630-639
[3]   DYNAMIC PENUMBRA DEMONSTRATED BY SEQUENTIAL MULTITRACER PET AFTER MIDDLE CEREBRAL-ARTERY OCCLUSION IN CATS [J].
HEISS, WD ;
GRAF, R ;
WIENHARD, K ;
LOTTGEN, J ;
SAITO, R ;
FUJITA, T ;
ROSNER, G ;
WAGNER, R .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1994, 14 (06) :892-902
[4]  
JOHNSON P, 1973, PERIPHERAL CIRCULATI, P3
[5]   INVIVO MEASUREMENT OF REGIONAL CEREBRAL HEMATOCRIT USING POSITRON EMISSION TOMOGRAPHY [J].
LAMMERTSMA, AA ;
BROOKS, DJ ;
BEANEY, RP ;
TURTON, DR ;
KENSETT, MJ ;
HEATHER, JD ;
MARSHALL, J ;
JONES, T .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (03) :317-322
[7]   Cerebral [O-15]water clearance in humans determined by PET .1. Theory and normal values [J].
Ohta, S ;
Meyer, E ;
Fujita, H ;
Reutens, DC ;
Evans, A ;
Gjedde, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (05) :765-780
[8]   High resolution measurement of cerebral blood flow using intravascular tracer bolus passages .2. Experimental comparison and preliminary results. [J].
Ostergaard, L ;
Sorensen, AG ;
Kwong, KK ;
Weisskoff, RM ;
Gyldensted, C ;
Rosen, BR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (05) :726-736
[9]   High resolution measurement of cerebral blood flow using intravascular tracer bolus passages .1. Mathematical approach and statistical analysis [J].
Ostergaard, L ;
Weisskoff, RM ;
Chesler, DA ;
Gyldensted, C ;
Rosen, BR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (05) :715-725
[10]  
Porkka L.M., 1991, P SOC MAGN RES MED 1, P120