A correction factor for the amplitude adjustment for the pulse echo ultrasonic inspection of components with curved surfaces

被引:5
|
作者
Michurov, A. V. [1 ]
Sokolkin, A. V. [1 ]
机构
[1] OOO Rubezh, Megion, Russia
关键词
correction factor; factor of limited contact; defocus factor; delay factor; attenuation coefficient; roughness factor; transmission factor of border; curved entry surface; pulse-echo method; amplitude;
D O I
10.1134/S106183091601006X
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
On the basis of analyzed factors that lead to the amplitude variation of an echo signal from identical reflectors in a quality-control sample and a test sample with curved surfaces, the correction factor for the amplitude adjustment is represented as the product of several factors. Calculation methods are proposed for the components of the correction factor for the case of a curved entry surface of an arbitrary shape and a position relative to the transducer.
引用
收藏
页码:14 / 22
页数:9
相关论文
共 47 条
  • [21] Model-Based Software for Simulating Ultrasonic Pulse/Echo Inspections of Metal Components
    Chiou, Chien-Ping
    Margetan, Frank J.
    Taylor, Jared L.
    McKillip, Matthew
    Engle, Brady J.
    Roberts, Ronald A.
    Barnard, Daniel J.
    43RD REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, 2017, 1806
  • [22] Evaluating the grain size in curved components using the ultrasonic attenuation method with diffraction correction
    Zhang, Chenxin
    Li, Xiongbing
    Song, Yongfeng
    Han, Xiaoqin
    Han, Jun
    NDT & E INTERNATIONAL, 2016, 84 : 20 - 26
  • [23] FULL-FIELD PULSE-ECHO ULTRASONIC WAVE PROPAGATION IMAGING FOR NONDESTRUCTIVE COMPOSITE INSPECTION
    Hong, Seung-Chan
    Lee, Jung-Ryul
    20TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS, 2015,
  • [24] Parametric optimization of pulse-echo laser ultrasonic system for inspection of thick polymer matrix composites
    Abetew, A. D.
    Truong, T. C.
    Hong, S. C.
    Lee, J. R.
    Ihn, J. B.
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2020, 19 (02): : 443 - 453
  • [25] Dry-coupled pulse echo ultrasonic inspection methodology for solid graphite products of rocket boosters
    Ravindran, VK
    Bhaumik, BC
    DEFENCE SCIENCE JOURNAL, 2002, 52 (01) : 27 - 32
  • [26] Grouting Inspection of PC Bridge Girder Using Ultrasonic Pulse Echo Tomography and Multiparameter Evaluation Procedure
    Sagradyan, A.
    Ogura, N.
    Shiotani, T.
    e-Journal of Nondestructive Testing, 2024, 29 (06):
  • [27] Evaluation of small defects in carbon fibre-reinforced composites using ultrasonic pulse echo amplitude
    Wong, B.S.
    Tui, C.G.
    Tan, K.S.
    Kwan, K.W.
    Insight: Non-Destructive Testing and Condition Monitoring, 1997, 39 (04): : 257 - 263
  • [28] Evaluation of small defects in carbon fibre-reinforced composites using ultrasonic pulse echo amplitude
    Wong, BS
    Tui, CG
    Tan, KS
    Kwan, KW
    INSIGHT, 1997, 39 (04) : 257 - 263
  • [29] Experimental investigation of finite amplitude distortion-based, second harmonic pulse echo ultrasonic imaging
    Christopher, T
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (01) : 158 - 162
  • [30] ACCURACY OF MEASUREMENT OF ATTENUATION FACTOR OF ULTRASONIC VIBRATIONS BY ECHO-PULSE CONTACT METHOD
    ROKHLIN, LL
    INDUSTRIAL LABORATORY, 1971, 37 (07): : 1008 - &