A correction factor for the amplitude adjustment for the pulse echo ultrasonic inspection of components with curved surfaces

被引:5
|
作者
Michurov, A. V. [1 ]
Sokolkin, A. V. [1 ]
机构
[1] OOO Rubezh, Megion, Russia
关键词
correction factor; factor of limited contact; defocus factor; delay factor; attenuation coefficient; roughness factor; transmission factor of border; curved entry surface; pulse-echo method; amplitude;
D O I
10.1134/S106183091601006X
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
On the basis of analyzed factors that lead to the amplitude variation of an echo signal from identical reflectors in a quality-control sample and a test sample with curved surfaces, the correction factor for the amplitude adjustment is represented as the product of several factors. Calculation methods are proposed for the components of the correction factor for the case of a curved entry surface of an arbitrary shape and a position relative to the transducer.
引用
收藏
页码:14 / 22
页数:9
相关论文
共 47 条
  • [1] A correction factor for the amplitude adjustment for the pulse echo ultrasonic inspection of components with curved surfaces
    A. V. Michurov
    A. V. Sokolkin
    Russian Journal of Nondestructive Testing, 2016, 52 : 14 - 22
  • [2] INFLUENCE OF THE DIMENSIONS OF AN ANGULAR REFLECTOR ON THE AMPLITUDE OF THE ECHO SIGNAL IN ADJUSTMENT OF ULTRASONIC INSPECTION UNITS
    ZAGORULKO, VS
    STIPURA, AP
    VYUNICHENKO, VN
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1986, 22 (06): : 403 - 407
  • [3] INFLUENCE OF THE DIMENSIONS OF AN ANGULAR REFLECTOR ON THE AMPLITUDE OF THE ECHO SIGNAL IN ADJUSTMENT OF ULTRASONIC INSPECTION UNITS.
    Zagorul'ko, V.S.
    Stipura, A.P.
    V'yunichenko, V.N.
    The Soviet journal of nondestructive testing, 1986, 22 (06): : 403 - 407
  • [4] Distance amplitude correction factors for immersion ultrasonic measurements through curved surfaces
    Gray, T
    Garton, M
    Zombo, P
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 15A AND 15B, 1996, 15 : 89 - 96
  • [5] CALIBRATION OF ULTRASONIC SYSTEMS FOR INSPECTION FROM CURVED SURFACES
    BIRCHAK, JR
    SERABIAN, S
    MATERIALS EVALUATION, 1978, 36 (01) : 39 - 44
  • [6] CALIBRATION OF ULTRASONIC SYSTEMS FOR INSPECTION FROM CURVED SURFACES
    BIRCHAK, JR
    SERABIAN, S
    MATERIALS EVALUATION, 1976, 34 (09) : P6 - P6
  • [7] Correction to: Laser ultrasonic inspection of additive manufactured components
    Geo Davis
    Romesh Nagarajah
    Suresh Palanisamy
    Rizwan Abdul Rahman Rashid
    Prabhu Rajagopal
    Krishnan Balasubramaniam
    The International Journal of Advanced Manufacturing Technology, 2022, 122 : 1113 - 1113
  • [8] A NEW APPROACH TO CALIBRATING FOR DISTANCE AMPLITUDE CORRECTION AND ULTRASONIC INSPECTION
    RUMBOLD, JG
    JACKSON, JL
    MATERIALS EVALUATION, 1981, 39 (05) : 459 - 461
  • [9] Evaluation of the Echo Signal by Ultrasonic pulse Amplitude and Phase Spectroscopy.
    Nabel, Eberhard
    Materialpruefung/Materials Testing, 1977, 19 (02): : 58 - 64
  • [10] Sensitivity compensation method in ultrasonic inspection for curved components with variable thickness
    Zhou, X.-J. (cmeesky@163.com), 1600, Zhejiang University (47):