Probing ligand-protein recognition with sum-frequency generation spectroscopy:: The avidin-biocytin case

被引:40
作者
Dreesen, L
Sartenaer, Y
Humbert, C
Mani, AA
Méthivier, C
Pradier, CM
Thiry, PA
Peremans, A
机构
[1] Univ Namur, Lab Spect Mol Surface, B-5000 Namur, Belgium
[2] Ecole Natl Super Chim Paris, CNRS, Lab Phys Chim Surfaces, UMR 7045, F-75231 Paris 05, France
关键词
biosensors; laser spectroscopy; molecular recognition; monolayers; vibrational spectroscopy;
D O I
10.1002/cphc.200400213
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Infrared/visible sum-frequency generation (SFG) spectroscopy is used to study the recognition of a protein (avidin) by a derived vitamin (biocytin) adsorbed on a calcium fluoride substrate. The specificity of the process is tested by replacing avidin with bovine serum albumin or presaturated avidin. The SFG spectroscopy shows drastic modifications in the CH and NH spectral ranges only upon exposure of the biocytin film to avidin. The comparison of the SFG data with Fourier transform infrared reflection absorption spectra (FT-IRRAS) in the some spectral ranges illustrates the advantages of nonlinear spectroscopy for studying and detecting recognition between biomolecules.
引用
收藏
页码:1719 / 1725
页数:7
相关论文
共 43 条
  • [1] SUM-FREQUENCY VIBRATIONAL SPECTROSCOPY OF THE SOLID-LIQUID INTERFACE
    BAIN, CD
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1995, 91 (09): : 1281 - 1296
  • [2] Synthesis of novel biotin anchors
    Booth, C
    Bushby, RJ
    Cheng, YL
    Evans, SD
    Liu, QY
    Zhang, HL
    [J]. TETRAHEDRON, 2001, 57 (49) : 9859 - 9866
  • [3] Ab initio calculations of vibrational spectra of 2-methoxy ethanol in the C-H stretching range
    Buck, M
    [J]. PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2003, 5 (01) : 18 - 25
  • [4] CARTER DC, 1994, ADV PROTEIN CHEM, V45, P153
  • [5] Clarkson J, 2000, J RAMAN SPECTROSC, V31, P373, DOI 10.1002/1097-4555(200005)31:5<373::AID-JRS519>3.0.CO
  • [6] 2-H
  • [7] De Paris R., 2000, Single Molecules, V1, P285
  • [8] Study of the water/poly(ethylene glycol) interface by IR-visible sum-frequency generation spectroscopy
    Dreesen, L
    Humbert, C
    Hollander, P
    Mani, AA
    Ataka, K
    Thiry, PA
    Peremans, A
    [J]. CHEMICAL PHYSICS LETTERS, 2001, 333 (05) : 327 - 331
  • [9] Sum-frequency generation spectroscopy applied to model biosensors systems
    Dreesen, L
    Sartenaer, Y
    Humbert, C
    Mani, AA
    Lemaire, JJ
    Méthivier, C
    Pradier, CM
    Thiry, PA
    Peremans, A
    [J]. THIN SOLID FILMS, 2004, 464 : 373 - 378
  • [10] Ferri D, 2002, HELV CHIM ACTA, V85, P3639, DOI 10.1002/1522-2675(200211)85:11<3639::AID-HLCA3639>3.0.CO