Prospective Randomized Trial Comparing Alumina Ceramic-on-Ceramic With Ceramic-On-Conventional Polyethylene Bearings in Total Hip Arthroplasty

被引:60
作者
Lewis, Peter M. [1 ]
Al-Belooshi, Ali [1 ]
Olsen, Michael [1 ]
Schemitch, Emil H. [1 ]
Waddell, James P. [1 ]
机构
[1] St Michaels Hosp, Dept Surg, Div Orthopaed, Toronto, ON M5B 1W8, Canada
关键词
Ceramic; total hip arthroplasty; polyethylene; wear; LOW-FRICTION ARTHROPLASTY; PATIENTS YOUNGER; FEMORAL-HEAD; SOCKET WEAR; FOLLOW-UP; REPLACEMENT; PENETRATION; ACCURACY; CHROMIUM; COBALT;
D O I
10.1016/j.arth.2009.01.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This prospective randomized study aims to compare the outcome between an alumina ceramic-on-ceramic (CC) articulation with a ceramic on ultra-high-molecular-weight polyethylene articulation (CP). Fifty-six hips in 55 patients with mean age 42.2 (range, 19-56) each received uncemented components, a 28-mm alumina head with randomization of acetabular liner. Mean St Michael's outcome score for each group with up to 10 years follow-up (median, 8 years; range, 1-10) was 22.8 and 22.9, respectively (P=.819). Wear was identified in all but 1 CP replacement, but only 12 of the 23 CC. Mean wear in the CP group was 0.11 mm/y and 0.02 mm/yr in the CC group (P<.001). Other than significantly greater wear in the polyethylene group, there was no significant difference in midterm outcome between the 2 groups.
引用
收藏
页码:392 / 397
页数:6
相关论文
共 48 条
[1]   Revision total hip arthroplasty performed after fracture of a ceramic femoral head - A multicenter survivorship study [J].
Allain, J ;
Roudot-Thoraval, F ;
Delecrin, J ;
Anract, P ;
Migaud, H ;
Goutallier, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :825-830
[2]  
ALPERT B, 1992, CLIN ORTHOP RELAT R, P164
[3]  
Bal BS, 2005, HIP INT, V15, P129, DOI 10.5301/HIP.2008.803
[4]   Radiographic wear measurements in a cementless metal-backed modular cobalt-chromium acetabular component [J].
Barrack, RL ;
Lavernia, C ;
Szuszczewicz, ES ;
Sawhney, J .
JOURNAL OF ARTHROPLASTY, 2001, 16 (07) :820-828
[5]   Concerns about ceramics in THA [J].
Barrack, RL ;
Barak, C ;
Skinner, HB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :73-79
[6]   Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years - A six- to 11-year evaluation [J].
Bizot, P ;
Hannouche, D ;
Nizard, R ;
Witvoet, J ;
Sedel, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (02) :190-194
[7]   Arthroplasty options for the young patient [J].
Bourne, RB ;
Barrack, R ;
Rorabeck, CH ;
Salehi, A ;
Good, V .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) :159-167
[8]   Comparison of two digital radio stereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantom [J].
Bragdon, CR ;
Estok, DM ;
Malchau, H ;
Kärrholm, J ;
Yuan, XH ;
Bourne, R ;
Veldhoven, J ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (03) :659-664
[9]   Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty [J].
Collier, MB ;
Kraay, MJ ;
Rimnac, CM ;
Goldberg, VM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12) :2410-2418
[10]   Alumina ceramic bearings for total hip arthroplasty - Five-year results of a prospective randomized study [J].
D'Antonio, J ;
Capello, W ;
Manley, M ;
Naughton, M ;
Sutton, K .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) :164-171