Flexible Microdisplacement Sensor for Wearable/Implantable Biomedical Applications

被引:18
作者
Ceron Hurtado, Nathalie Marcela [1 ,2 ]
Zarifi, Mohammad Hossein [3 ]
Daneshmand, Mojgan [3 ]
Aguilo Llobet, Jordi [1 ,2 ,4 ]
机构
[1] Autonomous Univ Barcelona, Microelect & Elect Syst Dept, E-08193 Barcelona, Spain
[2] CIBER BBN, Biomonitoring Grp, Bellaterra 08193, Spain
[3] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2R3, Canada
[4] IMB CNM, Integrated Syst Dept, Microelect Inst Barcelona, Bellaterra 08193, Spain
关键词
Microfabricated flexible sensor; interdigitated parallel plate capacitor (IPPC); microdisplacements; technical feasibility; frequency shift; CAPACITIVE DISPLACEMENT SENSOR; HEALTH-CARE; INTERNET; CIRCUIT; THINGS; IOT; RESONATOR; WIRELESS;
D O I
10.1109/JSEN.2017.2698263
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wireless monitoring systems are becoming a popular technology in noninvasive diagnosis. Based on current technological trends, low-power consumption, flexibility, small size, disposability, and low cost are the most important parameters to consider when designing sensors for biomedical applications. Echoing this trend, this paper presents a flexible wearable/implantable biocompatible sensor using wireless passive detection scheme, for future studying of the dynamics of an implanted abdominal mesh. Recording information about mechanical behavior of the implanted mesh helps in understanding hernia recurrence, among other post-surgical problems. Microfabricated sliding interdigitated gold plates and a circular coil (parallel inductor-capacitor tank) on a flexible substrate constitute the sensor's main core. The capacitance and, in consequence, the resonant frequency of the sensor will vary according to the sliding magnitude, because the overlapping area between the interdigitated plates changes on sliding. Thus, the monitored resonant frequency is the sensor response. Different thicknesses cyclo-olefin polymer was used as a dielectric layer. Phantom was used to the ex vivo characterization of tissue behavior. The capacitor was tested in a 0-600 mu m displacement's range. The measured sensitivity was 0.04 and 0.85 pF/50 mu m in simulated conditions, with a resolution of less than 1 mu m. The maximum sensitivity in the frequency range was 410 kHz/50 mu m. The frequency shift can be detected by an external readout coil up to 20 mm in air and 10 mm in phantom. The experimental results confirm the scalability of the sensor.
引用
收藏
页码:3873 / 3883
页数:11
相关论文
共 37 条
[11]   An LC Passive Wireless Multifunctional Sensor Using a Relay Switch [J].
Dong, Lei ;
Wang, Li-Feng ;
Huang, Qing-An .
IEEE SENSORS JOURNAL, 2016, 16 (12) :4968-4973
[12]  
Dutton W. H., 2015, SSRN ELECT J, P1
[13]  
Electronic Communication Committee (ECC) European Conference of Postal and Telecommunications Administrations (CEPT), 2016, EUR TABL FREQ ALL AP, P277
[14]   Submersible Printed Split-Ring Resonator-Based Sensor for Thin-Film Detection and Permittivity Characterization [J].
Galindo-Romera, Gabriel ;
Javier Herraiz-Martinez, Francisco ;
Gil, Marta ;
Juan Martinez-Martinez, Jose ;
Segovia-Vargas, Daniel .
IEEE SENSORS JOURNAL, 2016, 16 (10) :3587-3596
[15]   Internet of Things (IoT): A vision, architectural elements, and future directions [J].
Gubbi, Jayavardhana ;
Buyya, Rajkumar ;
Marusic, Slaven ;
Palaniswami, Marimuthu .
FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2013, 29 (07) :1645-1660
[16]   Theoretical and experimental study of capacitance considering fabrication process and edge effect for MEMS comb actuator [J].
Guo Zhanshe ;
Feng Zhou ;
Cao Le ;
Fan Shangchun .
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2011, 17 (01) :71-76
[17]   A cyclo olefin polymer microfluidic chip with integrated gold microelectrodes for aqueous and non-aqueous electrochemistry [J].
Illa, Xavi ;
Ordeig, Olga ;
Snakenborg, Detlef ;
Romano-Rodriguez, Albert ;
Compton, Richard G. ;
Kutter, Jorg P. .
LAB ON A CHIP, 2010, 10 (10) :1254-1261
[18]   Design and Optimization of Printed Spiral Coils for Efficient Transcutaneous Inductive Power Transmission [J].
Jow, Uei-Ming ;
Ghovanloo, Maysam .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2007, 1 (03) :193-202
[19]   A new capacitive displacement sensor with high accuracy and long-range [J].
Kim, Moojin ;
Moon, Wonkyu ;
Yoon, Euisung ;
Lee, Kwang-Ryeol .
SENSORS AND ACTUATORS A-PHYSICAL, 2006, 130 (135-141) :135-141
[20]   Rapid, Sensitive, and Reusable Detection of Glucose by a Robust Radiofrequency Integrated Passive Device Biosensor Chip [J].
Kim, Nam-Young ;
Adhikari, Kishor Kumar ;
Dhakal, Rajendra ;
Chuluunbaatar, Zorigt ;
Wang, Cong ;
Kim, Eun-Soo .
SCIENTIFIC REPORTS, 2015, 5