Flexible Microdisplacement Sensor for Wearable/Implantable Biomedical Applications

被引:18
作者
Ceron Hurtado, Nathalie Marcela [1 ,2 ]
Zarifi, Mohammad Hossein [3 ]
Daneshmand, Mojgan [3 ]
Aguilo Llobet, Jordi [1 ,2 ,4 ]
机构
[1] Autonomous Univ Barcelona, Microelect & Elect Syst Dept, E-08193 Barcelona, Spain
[2] CIBER BBN, Biomonitoring Grp, Bellaterra 08193, Spain
[3] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2R3, Canada
[4] IMB CNM, Integrated Syst Dept, Microelect Inst Barcelona, Bellaterra 08193, Spain
关键词
Microfabricated flexible sensor; interdigitated parallel plate capacitor (IPPC); microdisplacements; technical feasibility; frequency shift; CAPACITIVE DISPLACEMENT SENSOR; HEALTH-CARE; INTERNET; CIRCUIT; THINGS; IOT; RESONATOR; WIRELESS;
D O I
10.1109/JSEN.2017.2698263
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wireless monitoring systems are becoming a popular technology in noninvasive diagnosis. Based on current technological trends, low-power consumption, flexibility, small size, disposability, and low cost are the most important parameters to consider when designing sensors for biomedical applications. Echoing this trend, this paper presents a flexible wearable/implantable biocompatible sensor using wireless passive detection scheme, for future studying of the dynamics of an implanted abdominal mesh. Recording information about mechanical behavior of the implanted mesh helps in understanding hernia recurrence, among other post-surgical problems. Microfabricated sliding interdigitated gold plates and a circular coil (parallel inductor-capacitor tank) on a flexible substrate constitute the sensor's main core. The capacitance and, in consequence, the resonant frequency of the sensor will vary according to the sliding magnitude, because the overlapping area between the interdigitated plates changes on sliding. Thus, the monitored resonant frequency is the sensor response. Different thicknesses cyclo-olefin polymer was used as a dielectric layer. Phantom was used to the ex vivo characterization of tissue behavior. The capacitor was tested in a 0-600 mu m displacement's range. The measured sensitivity was 0.04 and 0.85 pF/50 mu m in simulated conditions, with a resolution of less than 1 mu m. The maximum sensitivity in the frequency range was 410 kHz/50 mu m. The frequency shift can be detected by an external readout coil up to 20 mm in air and 10 mm in phantom. The experimental results confirm the scalability of the sensor.
引用
收藏
页码:3873 / 3883
页数:11
相关论文
共 37 条
[1]   RFID Technology for IoT-Based Personal Healthcare in Smart Spaces [J].
Amendola, Sara ;
Lodato, Rossella ;
Manzari, Sabina ;
Occhiuzzi, Cecilia ;
Marrocco, Gaetano .
IEEE INTERNET OF THINGS JOURNAL, 2014, 1 (02) :144-152
[2]   The Internet of Things: A survey [J].
Atzori, Luigi ;
Iera, Antonio ;
Morabito, Giacomo .
COMPUTER NETWORKS, 2010, 54 (15) :2787-2805
[3]   An analytical fringe capacitance model for interconnects using conformal mapping [J].
Bansal, Aditya ;
Paul, Bipul C. ;
Roy, Kaushik .
IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2006, 25 (12) :2765-2774
[4]   Miniaturized Quasi-Lumped Resonator for Dielectric Characterization of Liquid Mixtures [J].
Benkhaoua, Larbi ;
Benhabiles, Mohamed Taoufik ;
Mouissat, Smail ;
Riabi, Mohamed Lahdi .
IEEE SENSORS JOURNAL, 2016, 16 (06) :1603-1610
[5]   On the Internet of Things, smart cities and the WHO Healthy Cities [J].
Boulos, Maged N. Kamel ;
Al-Shorbaji, Najeeb M. .
INTERNATIONAL JOURNAL OF HEALTH GEOGRAPHICS, 2014, 13
[6]   Crowdsourcing, citizen sensing and sensor web technologies for public and environmental health surveillance and crisis management: trends, OGC standards and application examples [J].
Boulos, Maged N. Kamel ;
Resch, Bernd ;
Crowley, David N. ;
Breslin, John G. ;
Sohn, Gunho ;
Burtner, Russ ;
Pike, William A. ;
Jezierski, Eduardo ;
Chuang, Kuo-Yu Slayer .
INTERNATIONAL JOURNAL OF HEALTH GEOGRAPHICS, 2011, 10
[7]   An IoT-Aware Architecture for Smart Healthcare Systems [J].
Catarinucci, Luca ;
de Donno, Danilo ;
Mainetti, Luca ;
Palano, Luca ;
Patrono, Luigi ;
Stefanizzi, Maria Laura ;
Tarricone, Luciano .
IEEE INTERNET OF THINGS JOURNAL, 2015, 2 (06) :515-526
[8]   ANALYTICAL IC METAL-LINE CAPACITANCE FORMULAS [J].
CHANG, WH .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1976, 24 (09) :608-611
[9]   A readout circuit for an intra-ocular pressure sensor [J].
Coosemans, J ;
Catrysse, M ;
Puers, R .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 110 (1-3) :432-438
[10]  
Deif S., 2016, 17 INT S ANTENNA TEC, P1