A comparison of bonfils fiberscope-assisted laryngoscopy and standard direct laryngoscopy in simulated difficult pediatric intubation: a manikin study

被引:19
|
作者
Vlatten, Arnim [1 ,2 ]
Aucoin, Sylvie [2 ]
Litz, Sharon [1 ,2 ]
MacManus, Brian [1 ,2 ]
Soder, Chris [1 ,2 ]
机构
[1] IWK Hlth Ctr, Dept Pediat Anesthesia & Pediat Crit Care, Halifax, NS B3K 6R8, Canada
[2] Dalhousie Univ, Dept Anesthesia, Halifax, NS, Canada
关键词
airway; pediatric; manikin; bonfils fiberscope; AIRWAY MANAGEMENT; CERVICAL-SPINE; CHILDREN; ANESTHESIA; MACINTOSH; MOVEMENT;
D O I
10.1111/j.1460-9592.2010.03298.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Introduction: Difficult airway management in children is challenging. One alternative device to the gold standard of direct laryngoscopy is the STORZ Bonfils fiberscope (Karl Storz Endoscopy, Tuttlingen, Germany), a rigid fiberoptic stylette-like scope with a curved tip. Although results in adults have been encouraging, reports regarding its use in children have been conflicting. We compared the effectiveness of a standard laryngoscope to the Bonfils fiberscope in a simulated difficult infant airway. Methods: Ten pediatric anesthesiologists were recruited for this study and asked to perform three sets of tasks. For the first task, each participant intubated an unaltered manikin (SimBaby (TM), Laerdal, Puchheim, Germany) five times using a styletted 3.5 endotracheal tube (ETT) and a Miller 1 blade (group DL-Normal). For the second task, a difficult airway configuration simulating a Cormack-Lehane grade 3B view was created by fixing a Miller-1 blade into position in the manikin using a laboratory stand. Each participant then intubated the manikin five times with a styletted 3.5 ETT using conventional technique but without touching the laryngoscope (group DL-Difficult). In the third task, the manikin was kept in the same difficult airway configuration, and each participant intubated the manikin five times using a 3.5-mm ETT mounted on the Bonfils fiberscope as an adjunct to direct laryngoscopy with the Miller-1 blade (group BF-Difficult). Primary outcomes were time to intubate and success rate. Results: A total of 150 intubations were performed. Correct ETT placement was achieved in 100% of attempts in group DL-Normal, 90% of attempts in group DL-Difficult and 98% of attempts in BF-Difficult. Time to intubate averaged 14 s (interquartile range 12-16) in group DL-Normal; 12 s (10-15) in group DL-Difficult; and 11 s (10-18) in group BF-Difficult. The percentage of glottic opening seen (POGO score) was 70% (70-80) in group DL-Normal; 0% (0-0) in group DL-Difficult; and 100% (100-100) in group BF-Difficult. Discussion: The Bonfils fiberscope-assisted laryngoscopy was easier to use and provided a better view of the larynx than simple direct laryngoscopy in the simulated difficult pediatric airway, but intubation success rate and time to intubate were not improved. Further studies of the Bonfils fibrescope as a pediatric airway adjunct are needed.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 50 条
  • [1] Comments on comparison of Bonfils fiberscope-assisted laryngoscopy with standard direct laryngoscopy in simulated difficult pediatric intubation
    Xue, Fu S.
    Liu, He P.
    Xiong, Jun
    Yuan, Yu J.
    Liao, Xu
    PEDIATRIC ANESTHESIA, 2010, 20 (08) : 778 - 779
  • [2] A Comparison of Direct Laryngoscopy and Videolaryngoscopy for Endotracheal Intubation by Inexperienced Users: A Pediatric Manikin Study
    Balaban, Onur
    Hakim, Mumin
    Walia, Hina
    Tumin, Dmitry
    Lind, Meredith
    Tobias, Joseph D.
    PEDIATRIC EMERGENCY CARE, 2020, 36 (04) : 169 - 172
  • [3] A comparison between left molar direct laryngoscopy and the use of a Bonfils intubation fibrescope for tracheal intubation in a simulated difficult airway
    Gupta, Anju
    Thukral, Seema
    Lakra, Archana
    Kumar, Sushil
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2015, 62 (06): : 609 - 617
  • [4] A comparison of McGrath MACA® and standard direct laryngoscopy in simulated immobilized cervical spine pediatric intubation: a manikin study
    Madziala, Marcin
    Smereka, Jacek
    Dabrowski, Marek
    Leung, Steve
    Ruetzler, Kurt
    Szarpak, Lukasz
    EUROPEAN JOURNAL OF PEDIATRICS, 2017, 176 (06) : 779 - 786
  • [5] Comparison of Bullard and Airtraq laryngoscopes with conventional laryngoscopy in a manikin study of simulated difficult intubation
    Legrand, Maria A. -L.
    Steinmann, Daniel
    Priebe, Hans-Joachim
    Mols, Georg
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2012, 29 (07) : 343 - 350
  • [6] A comparison of McGrath MAC® and standard direct laryngoscopy in simulated immobilized cervical spine pediatric intubation: a manikin study
    Marcin Madziala
    Jacek Smereka
    Marek Dabrowski
    Steve Leung
    Kurt Ruetzler
    Lukasz Szarpak
    European Journal of Pediatrics, 2017, 176 : 779 - 786
  • [7] Tracheal intubation with the Bonfils fiberscope in the difficult pediatric airway: a comparison with fiberoptic intubation
    Kaufmann, Jost
    Laschat, Michael
    Engelhardt, Thomas
    Hellmich, Martin
    Wappler, Frank
    PEDIATRIC ANESTHESIA, 2015, 25 (04) : 372 - 378
  • [8] COMPARISON OF THE C-MAC VIDEOLARYNGOSCOPE AND RIGID FIBERSCOPE WITH DIRECT LARYNGOSCOPY IN EASY AND DIFFICULT AIRWAY SCENARIOS: A MANIKIN STUDY
    Kaplan, Atilla
    Goksu, Erkan
    Yildiz, Gunay
    Kilic, Taylan
    JOURNAL OF EMERGENCY MEDICINE, 2016, 50 (03): : E107 - E114
  • [9] A comparison of the STORZ video laryngoscope and standard direct laryngoscopy for intubation in the Pediatric airway - a randomized clinical trial
    Vlatten, Arnim
    Aucoin, Sylvie
    Litz, Sharon
    Macmanus, Brian
    Soder, Chris
    PEDIATRIC ANESTHESIA, 2009, 19 (11) : 1102 - 1107
  • [10] Comparison of Video Laryngoscopy and Direct Laryngoscopy in the Success of Intubation Performed by Novice Personnel in Patients with Cervical Immobilization: A Manikin Study
    Can, Ozge
    Yalcinli, Sercan
    Altunci, Yusuf Ali
    FRONTIERS IN EMERGENCY MEDICINE, 2021, 5 (04):