Objective: To determine the response to small repeated variations in X-ray exposure of storage phosphor (SP) plates compared with Ektaspeed Plus dental film. Methods: Exposure of SP plates and Ektaspeed Plus dental him was varied within a small range [8.62 mu C kg(-1) to 9.03 mu C kg(-1), (5%)]. Radiographs were digitized and SP plates read with a laser-based scanner. Nested analysis of variance, analysis of covariance, and regression analysis were used to test the relationship between exposure and the resulting signal. Results: The relationship between exposure and signal for digital images of film radiographs was not significant whereas the corresponding relationship for SP images was highly significant (P<0.001, R-2 = 0.34). Conclusions: Over the narrow range of X-ray exposures studied there was a significant direct linear relationship between exposure and digital gray-scare values for SP images but not for digital images of Ektaspeed Plus films.
引用
收藏
页码:147 / 151
页数:5
相关论文
共 20 条
  • [1] BRAEGGER U, 1989, J CLIN PERIODONTOL, V16, P46
  • [2] BUSCH HP, 1992, DIGITAL RADIOGRAPHY
  • [3] A COMPARISON OF 6 INTRAORAL X-RAY-FILMS
    CONOVER, GL
    HILDEBOLT, CF
    ANTHONY, D
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (03) : 169 - 172
  • [4] PHYSICAL ASPECTS OF PHOTOSTIMULABLE PHOSPHOR COMPUTED RADIOGRAPHY
    COWEN, AR
    WORKMAN, A
    PRICE, JS
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (784) : 332 - 345
  • [5] CURRY TS, 1990, CHRISTENSENS PHYSICS
  • [6] FARMAN AG, 1995, COMPUTER ASSISTED RADIOLOGY, P949
  • [7] DIGITAL IMAGE-PROCESSING .1. EVALUATION OF GRAY-LEVEL CORRECTION METHODS IN-VITRO
    FOURMOUSIS, I
    BRAGGER, U
    BURGIN, W
    TONETTI, M
    LANG, NP
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1994, 5 (01) : 37 - 47
  • [8] GREEN RE, 1992, COMPUTED DIGITAL RAD
  • [9] COMPUTED RADIOGRAPHY UTILIZING LASER-STIMULATED LUMINESCENCE - DETECTABILITY OF SIMULATED LOW-CONTRAST RADIOGRAPHIC OBJECTS
    HIGASHIDA, Y
    MORIBE, N
    HIRATA, Y
    MORITA, K
    DOUDANUKI, S
    SONODA, Y
    KATSUDA, N
    HIAI, Y
    MISUMI, W
    MATSUMOTO, M
    YOSHIOKA, S
    TAKAHASHI, M
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1988, 12 (03) : 137 - 145
  • [10] INTERRELATIONSHIPS BETWEEN BONE-MINERAL CONTENT MEASURES - DUAL-ENERGY RADIOGRAPHY (DER) AND BITEWING RADIOGRAPHS (BWX)
    HILDEBOLT, CF
    RUPICH, RC
    VANNIER, MW
    ZERBOLIO, DJ
    SHROUT, MK
    COHEN, S
    PINKAS, A
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1993, 20 (10) : 739 - 745