Strategies to overcome interferences in elemental and isotopic geochemical analysis by quadrupole inductively coupled plasma mass spectrometry: A critical evaluation of the recent developments

被引:35
|
作者
Balaram, V [1 ]
机构
[1] CSIR Natl Geophys Res Inst, Hyderabad 500007, Andhra Pradesh, India
关键词
RARE-EARTH-ELEMENTS; COLLISION-REACTION INTERFACE; PLATINUM-GROUP ELEMENTS; NG G(-1) LEVELS; ICP-MS ANALYSIS; TRACE-ELEMENTS; REACTION CELL; GEOLOGICAL SAMPLES; ENVIRONMENTAL-SAMPLES; INTERNAL STANDARDIZATION;
D O I
10.1002/rcm.9065
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quadrupole Inductively Coupled Plasma Mass Spectrometry (ICP-MS) instruments were introduced into geochemical and mineral exploration laboratories nearly four decades ago, providing a technique that could meet their longstanding requirement for the precise and accurate determination of several groups of trace elements and isotopes in geological materials such as rocks, minerals, ores, soils, sediments, and natural water samples. Despite its popularity among geochemists, the technique suffered from spectral and non-spectral interferences some of which seriously affected the quality of the data generated. These interferences have also had a significant impact on the ability of ICP-MS systems to achieve low detection limits. Over the last three decades, technical advances such as the development of high-resolution (HR)-ICP-MS, cool plasma, collision/reaction cell technology (CCT), dynamic reaction cell (DRC) technology, collision reaction interface (CRI), kinetic energy discrimination (KED), tandem mass spectrometry (ICP-MS/MS)/triple quadrupole ICP-MS, and multi-quadrupole ICP-MS have been introduced to eliminate/minimize many of these interferences, with each technique having its strengths and limitations. These technologies have extended the range of elements that can be measured accurately not only in geological materials, but also in several other matrices, with lower detection limits than before. In addition, other methods such as internal standardization, isotope-dilution, standard addition and matrix-matching calibrations have contributed to improving the quality of the data. This paper provides a review of these new developments from the geochemical analysis point of view.
引用
收藏
页数:29
相关论文
共 50 条
  • [21] Inductively coupled plasma mass spectrometric techniques in the elemental and isotopic analysis of lanthanides and actinides
    Balaram, V
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2002, 79 (06) : 479 - 485
  • [22] Isotopic analysis of plutonium in foods by inductively-coupled plasma mass spectrometry
    Emanuele, Kathryn
    Lin, Zhichao
    Healey, Stephanie
    Shareef, Abdur-Rafay
    Regan, Patrick
    APPLIED RADIATION AND ISOTOPES, 2017, 126 : 40 - 43
  • [23] Femtosecond laser ablation inductively coupled plasma source mass spectrometry for elemental and isotopic analysis: are ultrafast lasers worthwhile?
    Poitrasson, Franck
    d'Abzac, Francois-Xavier
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (06) : 1075 - 1091
  • [24] ISOTOPIC AND ELEMENTAL ANALYSIS OF URANINITE CONCENTRATES USING INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS)
    LONGERICH, HP
    WILTON, DHC
    FRYER, BJ
    JOURNAL OF GEOCHEMICAL EXPLORATION, 1992, 43 (02) : 111 - 125
  • [25] Measurement of the isotopic abundance of boron-10 by inductively coupled plasma-quadrupole mass spectrometry
    Takasaki, Ippei
    Nagumo, Toshiaki
    Inaba, Toru
    Yoshino, Nobuyuki
    Maruyama, Tadashi
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2012, 49 (08) : 867 - 872
  • [26] Elemental and isotopic signatures of individual particles in chondrite matrix using inductively coupled plasma mass spectrometry
    Kurihara, Kanoko
    Numa, Norika
    Niki, Sota
    Akamune, Mai
    Nakazato, Masaki
    Yamashita, Shuji
    Itoh, Shoichi
    Hirata, Takafumi
    GEOCHEMICAL JOURNAL, 2023, 57 (05) : E9 - E16
  • [27] Strategies to Improve Accuracy and Sensitivity in Phosphorus Determinations by Inductively Coupled Plasma Quadrupole Mass Spectrometry
    Donati, George L.
    Amais, Renata S.
    Nobrega, Joaquim A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (04) : 786 - 791
  • [28] Isotopic and elemental imaging of geological materials by laser ablation inductively coupled plasma-mass spectrometry
    Woodhead, Jon D.
    Hellstrom, John
    Hergt, Janet M.
    Greig, Alan
    Maas, Roland
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2007, 31 (04) : 331 - 343
  • [29] Non-spectral and spectral interferences in inductively coupled plasma high-resolution mass spectrometry - Part 2. Comparison of interferences in quadrupole and high resolution inductively coupled plasma mass spectrometries
    Nonose, N
    Kubota, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (06) : 560 - 566
  • [30] Isotopic and Elemental Analysis of Apple and Orange Juice by Isotope Ratio Mass Spectrometry (IRMS) and Inductively Coupled Plasma - Mass Spectrometry (ICP-MS)
    Cristea, Gabriela
    Dehelean, Adriana
    Voica, Cezara
    Feher, Ioana
    Puscas, Romulus
    Magdas, Dana Alina
    ANALYTICAL LETTERS, 2021, 54 (1-2) : 212 - 226