Extended depth-of-focus (EDOF) AcrySof® IQ Vivity® intraocular lens implant: a real-life experience

被引:57
作者
Arrigo, Alessandro [1 ]
Gambaro, Gianpiera [2 ]
Fasce, Francesco [1 ]
Aragona, Emanuela [1 ]
Figini, Innocente [2 ]
Bandello, Francesco [1 ]
机构
[1] Univ Vita Salute San Raffaele, IRCCS San Raffaele Sci Inst, Dept Ophthalmol, Milan, Italy
[2] Valduce Hosp, Unit Ophthalmol, Como, Italy
关键词
Cataract surgery; IOL; EDOF; Quality of Vision score; VISUAL QUALITY; SATISFACTION;
D O I
10.1007/s00417-021-05245-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Extended depth-of-focus (EDOF) is a promising intraocular lens (IOL) technology for cataract surgery. The aim of the study was to report the real-life experience related to the implant of EDOF AcrySof (R) IQ Vivity (R) (Alcon Inc., USA) IOL. Methods The study was designed as a interventional, prospective, case series with 3 months of follow-up. Patients needing cataract surgery, without any other kind of ocular diseases, were recruited and implanted with AcrySof (R) IQ Vivity (R) IOL. We evaluated the refractive success of this IOL through complete ophthalmologic assessments and the administration of the Quality of Vision test. The main outcome measures were the refractive outcome; far, intermediate, and near vision; and Quality of Vision score. Results We included 108 eyes (54 patients; age 62 +/- 5 years). Intra-operative and post-operative complications were 0%. Thirty out of 100 eyes (28%) required toric IOL. Best-corrected visual acuity improved from 0.4 +/- 0.3 LogMAR to 0.0 +/- 0.0 LogMAR (p < 0.01). Refractive outcome was very good for far and intermediate visions, whereas a spherical addition of at least + 1.0D was required for near vision. The mean Quality of Vision score was of 15.5 +/- 6.5. The most complained visual disturbances were haloes and glares, although resulting well-tolerated. Dynamic pupillometry findings well-correlated with the amount of complained post-operative visual discomforts. Conclusions AcrySof (R) IQ Vivity (R) IOL is a well-tolerated choice to correct far and intermediate vision. Spectacles are needed to optimize near vision. Our data strongly suggest dynamic pupillometry as a useful investigation to optimize post-operative refractive success.
引用
收藏
页码:2717 / 2722
页数:6
相关论文
共 12 条
[1]   Evaluation of quality of life after implantation of a new trifocal intraocular lens [J].
Akman, Ahmet ;
Asena, Leyla ;
Ozturk, Caner ;
Gungor, Sirel Gur .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (02) :130-134
[2]   Multifocal intraocular lenses: Relative indications and contraindications for implantation [J].
Braga-Mele, Rosa ;
Chang, David ;
Dewey, Steven ;
Foster, Gary ;
Henderson, Bonnie An ;
Hill, Warren ;
Hoffman, Richard ;
Little, Brian ;
Mamalis, Nick ;
Oetting, Thomas ;
Serafano, Donald ;
Talley-Rostov, Audrey ;
Vasavada, Abhay ;
Yoo, Sonia .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (02) :313-322
[3]   Extended depth-of-focus intraocular lenses: power calculation and outcomes [J].
Coassin, Marco ;
Di Zazzo, Antonio ;
Antonini, Marco ;
Gaudenzi, Daniele ;
Gallo Afflitto, Gabriele ;
Kohnen, Thomas .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (11) :1554-1560
[4]   Comparing Visual Acuity, Low Contrast Acuity and Contrast Sensitivity After Trifocal Toric and Extended Depth of Focus Toric Intraocular Lens Implantation [J].
Gundersen, Kjell G. ;
Potvin, Rick .
CLINICAL OPHTHALMOLOGY, 2020, 14 :1071-1078
[5]   Visual Outcomes, Visual Quality and Patient Satisfaction: Comparing a Blended Bifocal Approach to Bilateral Extended Depth of Focus Intraocular Lens Implantation [J].
Hammond, Matthew D. ;
Potvin, Richard .
CLINICAL OPHTHALMOLOGY, 2019, 13 :2325-2332
[6]   Extended depth-of-focus technology in intraocular lenses [J].
Kohnen, Thomas ;
Suryakumar, Rajaraman .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (02) :298-304
[7]   The Development of an Instrument to Measure Quality of Vision: The Quality of Vision (QoV) Questionnaire [J].
McAlinden, Colm ;
Pesudovs, Konrad ;
Moore, Jonathan E. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (11) :5537-5545
[8]   A Comparative Evaluation of Diffractive Trifocal and New Refractive/Extended Depth of Focus Intraocular Lenses for Refractive Lens Exchange [J].
Ozulken, Kemal ;
Kiziltoprak, Hasan ;
Yuksel, Erdem ;
Mumcuoglu, Tarkan .
CURRENT EYE RESEARCH, 2021, 46 (06) :811-817
[9]   Comparing the visual outcome, visual quality, and satisfaction among three types of multi-focal intraocular lenses [J].
Paik, Dong Won ;
Park, Jun Sang ;
Yang, Chan Min ;
Lim, Dong Hui ;
Chung, Tae-Young .
SCIENTIFIC REPORTS, 2020, 10 (01)
[10]  
Rementeria-Capelo LA, 2021, INT OPHTHALMOL, V41