Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease

被引:182
作者
Ait-Ali, Lamia [2 ]
Andreassi, Maria Grazia [1 ,2 ]
Foffa, Ilenia [2 ]
Spadoni, Isabella
Vano, Eliseo [3 ,4 ]
Picano, Eugenio [2 ]
机构
[1] G Pasquinucci Hosp, Inst Clin Physiol, G Monasterio Fdn, CNR, I-54100 Massa, Italy
[2] CNR, Inst Clin Physiol, I-56100 Pisa, Italy
[3] Univ Complutense, E-28040 Madrid, Spain
[4] San Carlos Univ Hosp, Madrid, Spain
关键词
CARDIAC-CATHETERIZATION; COMPUTED-TOMOGRAPHY; INTERVENTIONAL CARDIOLOGY; CLINICAL COMPETENCE; AMERICAN-COLLEGE; UNITED-STATES; CANCER-RISKS; TASK-FORCE; EXPOSURE; ANGIOGRAPHY;
D O I
10.1136/hrt.2008.160309
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The seventh Committee on "Biological Effects of Ionizing Radiation" (BEIR VII, 2006) underlines "the need of studies of infants who are exposed to diagnostic radiation because catheters have been placed in their hearts". Objective To determine the lifetime attributable risk (LAR) of cancer associated with the estimated cumulative radiological dose in 59 children (42 male, age 2.8+/-3.2 years) with complex congenital heart disease, and to assess chromosomal DNA damage after cardiac catheterisation procedures. Methods In all patients, the cumulative exposure was estimated as effective dose in milliSievert (mSv), and LAR cancer was determined from the BEIR VII report. In a subset of 18 patients (13 male, age 5.2+/-5.7 years) micronucleus as a biomarker of DNA damage and long-term risk predictor of cancer was assayed before and 2 h after catheterisation procedures. Dosee-area product (Gy cm(2)) was assessed as a measure of patient dose. Results The median life time cumulative effective dose was 7.7 mSv per patient (range 4.6-41.2). Cardiac catheterisation procedures and CT were responsible for 95% of the total effective dose. For a 1-year-old child, the LAR cancer was 1 in 382 (25th to 75th centiles: 1 in 531 to 1 in 187) and 1 in 156 (25th to 75th centiles: 1 in 239 to 1 in 83) for male and female patients, respectively. Median micronucleus values increased significantly after the procedure in comparison with baseline (before 6 parts per thousand vs after 9 parts per thousand, p=0.02). The median dose-area product value was 20 Gy cm(2) (range 1-277). Conclusion Children with congenital heart disease are exposed to a significant cumulative dose. Indirect cancer risk estimations and direct DNA data both emphasise the need for strict radiation dose optimisation in children.
引用
收藏
页码:269 / 274
页数:6
相关论文
共 44 条
[1]  
ADAMS FH, 1978, PEDIATRICS, V62, P312
[2]  
Amis E Stephen Jr, 2007, J Am Coll Radiol, V4, P272, DOI 10.1016/j.jacr.2007.03.002
[3]   Cardiac catheterization and long-term chromosomal damage in children with congenital heart disease [J].
Andreassi, Maria Grazia ;
Ait-Ali, Lamia ;
Botto, Nicoletta ;
Manfredi, Samantha ;
Mottola, Gaetano ;
Picano, Eugenio .
EUROPEAN HEART JOURNAL, 2006, 27 (22) :2703-2708
[4]  
Au W W., 2006, Journal of Radiotherapy Research, V47, P13
[5]   Rising rates of cardiac procedures in the United States and Canada - Too much of a good thing? [J].
Ayanian, JZ .
CIRCULATION, 2006, 113 (03) :333-335
[6]   Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization [J].
Bacher, K ;
Bogaert, E ;
Lapere, R ;
De Wolf, D ;
Thierens, H .
CIRCULATION, 2005, 111 (01) :83-89
[7]   Cumulative patient effective dose in cardiology [J].
Bedetti, G. ;
Botto, N. ;
Andreassi, M. G. ;
Traino, C. ;
Vano, E. ;
Picano, E. .
BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (969) :699-705
[8]   Patient radiation doses during cardiac catheterization procedures [J].
Betsou, S ;
Efstathopoulos, EP ;
Katritsis, D ;
Faulkner, K ;
Panayiotakis, G .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (846) :634-639
[9]   An increased micronucleus frequency in peripheral blood lymphocytes predicts the risk of cancer in humans [J].
Bonassi, Stefano ;
Znaor, Ariana ;
Ceppi, Marcello ;
Lando, Cecilia ;
Chang, Wushou Peter ;
Holland, Nina ;
Kirsch-Volders, Micheline ;
Zeiger, Errol ;
Ban, Sadayuki ;
Barale, Roberto ;
Bigatti, Maria Paola ;
Bolognesi, Claudia ;
Cebulska-Wasilewska, Antonina ;
Fabianova, Eleonora ;
Fucic, Alexandra ;
Hagmar, Lars ;
Joksic, Gordana ;
Martelli, Antonietta ;
Migliore, Lucia ;
Mirkova, Ekaterina ;
Scarfi, Maria Rosaria ;
Zijno, Andrea ;
Norppa, Hannu ;
Fenech, Michael .
CARCINOGENESIS, 2007, 28 (03) :625-631
[10]   Radiation exposure to children during cardiac catheterization [J].
Boothroyd, A ;
McDonald, E ;
Moores, BM ;
Sluming, V ;
Carty, H .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 :180-185