A New Force Myography-Based Approach for Continuous Estimation of Knee Joint Angle in Lower Limb Amputees and Able-Bodied Subjects

被引:16
作者
Kumar, Amit [1 ]
Godiyal, Anoop Kant [1 ]
Joshi, Pradeep [2 ]
Joshi, Deepak [1 ,3 ]
机构
[1] Indian Inst Technol Delhi, Delhi 110016, India
[2] Graph Era Hill Univ, Dehra Dun 248002, Uttarakhand, India
[3] All India Inst Med Sci Delhi, New Delhi 110029, India
关键词
Knee; Legged locomotion; Thigh; Sensors; Goniometers; Muscles; Force; Force myography (FMG); artificial neural network (ANN); knee joint angle; ANKLE-FOOT ORTHOSIS; PREDICTION; LOCOMOTION; STRATEGIES; WALKING; DESIGN; ASSIST; SPEED;
D O I
10.1109/JBHI.2020.2993697
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, we present a new method for estimating knee joint angle using force myography. The technique utilized force myogram signals from thigh muscles while subjects walked on a treadmill at different speeds, i.e., slow, medium, fast, and run. An eight-channel in-house force myography (FMG) data acquisition system was developed to collect the data wirelessly from seven healthy subjects and a transfemoral amputee. An artificial neural network was employed to estimate the knee joint angle from force myogram signals. The root-mean-square error across the healthy subjects was 6.9 +/- 1.5 degrees at slow (1.5 km/hr), 6.5 +/- 1.3 degrees at medium (4 km/hr), 7.4 +/- 2.2 degrees at fast (6 km/hr) speeds, and 8.1 +/- 2.2 degrees while running (8 km/hr). The root-mean-square error, across the trials, for the transfemoral amputee was 4.0 +/- 1.2 degrees at slow (1 km/hr), 3.2 +/- 0.6 degrees at medium (2 km/hr) and 3.8 +/- 0.9 degrees at fast (3 km/hr) speeds. The proposed approach is useful in real-time gait analysis. The system is easily wearable, convenient in out-door use, portable, and commercially viable.
引用
收藏
页码:701 / 710
页数:10
相关论文
共 52 条
  • [1] The effect of perspiration on the sEMG amplitude and power spectrum
    Abdoli-Eramaki, Mohammad
    Damecour, Caroline
    Christenson, John
    Stevenson, Joan
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2012, 22 (06) : 908 - 913
  • [2] A proportional control scheme for high density force myography
    Belyea, Alexander T.
    Englehart, Kevin B.
    Scheme, Erik J.
    [J]. JOURNAL OF NEURAL ENGINEERING, 2018, 15 (04)
  • [3] Functional status of adults with cerebral palsy and implications for treatment of children
    Bottos, M
    Feliciangeli, A
    Sciuto, L
    Gericke, C
    Vianello, A
    [J]. DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2001, 43 (08) : 516 - 528
  • [4] Implications of assist-as-needed robotic step training after a complete spinal cord injury on intrinsic strategies of motor learning
    Cai, Lance L.
    Fong, Andy J.
    Otoshi, Chad K.
    Liang, Yongqiang
    Burdick, Joel W.
    Roy, Roland R.
    Edgerton, V. Reggie
    [J]. JOURNAL OF NEUROSCIENCE, 2006, 26 (41) : 10564 - 10568
  • [5] Proceedings of the first workshop on Peripheral Machine Interfaces: going beyond traditional surface electromyography
    Castellini, Claudio
    Artemiadis, Panagiotis
    Wininger, Michael
    Ajoudani, Arash
    Alimusaj, Merkur
    Bicchi, Antonio
    Caputo, Barbara
    Craelius, William
    Dosen, Strahinja
    Englehart, Kevin
    Farina, Dario
    Gijsberts, Arjan
    Godfrey, Sasha B.
    Hargrove, Levi
    Ison, Mark
    Kuiken, Todd
    Markovic, Marko
    Pilarski, Patrick M.
    Rupp, Ruediger
    Scheme, Erik
    [J]. FRONTIERS IN NEUROROBOTICS, 2014, 8 : 1 - 17
  • [6] Surface EMG based continuous estimation of human lower limb joint angles by using deep belief networks
    Chen, Jiangcheng
    Zhang, Xiaodong
    Cheng, Yu
    Xi, Ning
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 40 : 335 - 342
  • [7] Chu K. H, 2017, J REHABIL ASSIST TER, V4
  • [8] Inertial sensor-based knee flexion/extension angle estimation
    Cooper, Glen
    Sheret, Ian
    McMillian, Louise
    Siliverdis, Konstantinos
    Sha, Ning
    Hodgins, Diana
    Kenney, Laurence
    Howard, David
    [J]. JOURNAL OF BIOMECHANICS, 2009, 42 (16) : 2678 - 2685
  • [9] Curcio B. C., 2020, J PROSTHET ORTHOT, V32, P52
  • [10] A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes
    Dejnabadi, H
    Jolles, BM
    Aminian, K
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (08) : 1478 - 1484