Reliability and Time Efficiency of Digital vs. Analog Bite Registration Technique for the Manufacture of Full-Arch Fixed Implant Prostheses

被引:10
|
作者
Nuytens, Philippe [1 ]
D'haese, Rani [2 ]
Vandeweghe, Stefan [2 ]
机构
[1] Restorat Dent, B-8870 Izegem, Belgium
[2] Univ Ghent, Fac Med & Hlth Sci, Dent Sch, Dept Reconstruct Dent, B-9000 Ghent, Belgium
关键词
bite registration; implants; full-arch; complete arch; digital impression; intraoral scan; digital workflow; bite pillar; dual function scan body; EDENTULOUS MAXILLA; VERTICAL DIMENSION; REST POSITION; IN-VITRO; ACCURACY; IMPRESSIONS; DENTURE; REPRODUCIBILITY; TECHNOLOGY; WORKFLOW;
D O I
10.3390/jcm11102882
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Information about full-digital protocols for bite registration with intraoral scanners on multiple implants in the edentulous jaw is scarce. The purpose of this comparative in vivo study was to investigate the reliability and time efficiency of a novel full-digital bite registration technique for the manufacture of full-arch maxillary fixed implant prostheses. Material and methods: In ten patients, a full-arch maxillary fixed implant prosthesis was manufactured on multi-unit abutment level through an analog prosthetic workflow. The bite registration was performed with use of a screw-retained polymethyl methacrylate (PMMA) verification jig with detachable wax rim. To articulate the definitive edentulous maxillary implant cast in centric relation at the appropriate occlusal vertical dimension (OVD) to the mandibular antagonist cast, a type II articulator (Artex, Amann Girrbach) was used. Three to six months later, a full-digital bite registration was performed with use of dual-function scan bodies and bilateral connected bite pillars. The bite pillars screwed into the scan bodies were used to adjust and articulate the edentulous maxillary implant arch to the mandibular antagonist arch at the defined OVD. Treatment time for analog and digital bite registration technique was measured in each patient. The reliability of the digital bite registration technique was evaluated by 3D comparison of two sets of stereo lithographic (STL) files obtained from each patient. The three-dimensional deviation was defined along the X-, Y- and Z-axes (Geomagic Control X, 3D Systems Inc., Rock Hill, SC, USA). Results: The treatment time for digital bite registration using dual-function scan bodies and bite pillars was significantly shorter than analog bite registration with verification jig and wax rim (60.30%, SD 5.72%). Minor differences between the two techniques were observed with a linear deviation range of 1115 mu m (SD 668 mu m) overall, 46.2 mu m (SD 731.3 mu m) along the X-axis, -200.3 mu m (SD 744.3 mu m) along the Y-axis and 67.1 mu m (SD 752.2 mu m) along the Z-axis. Bilateral balanced contacts were registered in all patients during full-digital bite registration. Conclusions: The novel digital bite registration technique with dual-function scan bodies and bite pillars allows for a full-digital workflow for full-arch implant supported restorations. The digital bite workflow was 60% faster, and the overall deviation was around 1 mm, which can be considered clinically acceptable.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Digital vs. conventional full-arch implant impressions: a comparative study
    Amin, Sarah
    Weber, Hans Peter
    Finkelman, Matthew
    El Rafie, Khaled
    Kudara, Yukio
    Papaspyridakos, Panos
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (11) : 1360 - 1367
  • [2] Digital Workflow for Implant Rehabilitation with Double Full-Arch Monolithic Zirconia Prostheses
    Papaspyridakos, Panos
    Chochlidakis, Konstantinos
    Kang, Kiho
    Chen, Yo-wei
    Alghfeli, Abdulla
    Kudara, Yukio
    Weber, Hans-Peter
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (06): : 460 - 465
  • [3] Full-arch implant fixed prostheses: a comparative study on the effect of connection type and impression technique on accuracy of fit
    Papaspyridakos, Panos
    Hirayama, Hiroshi
    Chen, Chun-Jung
    Ho, Chung-Han
    Chronopoulos, Vasilios
    Weber, Hans-Peter
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (09) : 1099 - 1105
  • [4] Retrospective Cohort Evaluation of Full-Arch Zirconia Implant-Supported Fixed Prostheses
    Al-Tarawneh, Sandra
    Thalji, Ghadeer
    Shonberg, David
    Fayz, Lily
    Cooper, Lyndon
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (02) : 381 - +
  • [5] Complications of Fixed Full-Arch Implant-Supported Metal-Ceramic Prostheses
    Gonzalez-Gonzalez, Ignacio
    deLlanos-Lanchares, Hector
    Brizuela-Velasco, Aritza
    Alvarez-Riesgo, Jose-Antonio
    Llorente-Pendas, Santiago
    Herrero-Climent, Mariano
    Alvarez-Arenal, Angel
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (12) : 1 - 23
  • [6] In Vitro Accuracy of Digital and Conventional Impressions for Full-Arch Implant-Supported Prostheses
    D'haese, Rani
    Vrombaut, Tom
    Roeykens, Herman
    Vandeweghe, Stefan
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [7] A digital technique of bone reduction for a maxillary full-arch implant-supported fixed dental prosthesis
    Tang, Weimao
    Zhang, Hai
    Wang, Haozhe
    Li, Lei
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (07): : 714 - 719
  • [8] The influence of bone quality on the biomechanical behavior of full-arch implant-supported fixed prostheses
    Faverani, Leonardo Perez
    Ricardo Barao, Valentim Adelino
    Ramalho-Ferreira, Gabriel
    Delben, Juliana Aparecida
    Ferreira, Mayara Barbosa
    Garcia Junior, Idelmo Rangel
    Assuncao, Wirley Goncalves
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 37 : 164 - 170
  • [9] Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study
    Drancourt, Noemie
    Auduc, Chantal
    Mouget, Aymeric
    Mouminoux, Jean
    Auroy, Pascal
    Veyrune, Jean-Luc
    El Osta, Nada
    Nicolas, Emmanuel
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [10] Full-arch implant-supported monolithic zirconia fixed dental prostheses: An updated systematic review
    AlTarawneh, Sandra
    Thalji, Ghadeer
    Cooper, Lyndon
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2021, 14 (01) : 13 - 22