An Adaptive Reclosing Scheme for MMC-HVDC Systems Based on Pulse Injection From Parallel Energy Absorption Module

被引:36
作者
Mei, Jun [1 ]
Ge, Rui [1 ]
Zhu, Pengfei [1 ]
Fan, Guangyao [1 ]
Wang, Bingbing [1 ]
Yan, Lingxiao [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Peoples R China
基金
国家重点研发计划;
关键词
Circuit faults; Absorption; Capacitors; Fault currents; Inductors; Topology; HVDC transmission; MMC-HVDC; DC grids; active injection; adaptive reclosing; traveling wave; fault location;
D O I
10.1109/TPWRD.2020.3015311
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Modular multilevel converter (MMC) based high voltage direct current (HVDC) transmission system is one of the important development trends of DC power grid. After fault isolation, the traditional reclosing method of MMC-HVDC system is directly reclosing DC circuit breaker (DCCB). Once the fault point still exists, DCCB will be tripped again. This method will make the DC system suffer from the secondary strike of fault in a short time, and seriously endanger the service life of DCCB. In order to overcome the drawbacks of the traditional reclosing schemes, this paper proposes a novel adaptive reclosing scheme based on pulse injection from parallel energy absorption module. When dc fault current is interrupted by DCCB, the fault energy stored in current-limiting reactors (CLR) and dc lines is transferred to energy absorption module automatically. By switching on IGBTs embedded in absorption module for a short time, a voltage pulse is injected directly into the faulty line without interference from CLR. Then the nature of fault is identified and the fault distance can also be calculated in the case of permanent faults. The simulation results verify the effectiveness of the proposed reclosing scheme.
引用
收藏
页码:1809 / 1818
页数:10
相关论文
共 23 条
[1]  
Adam G.C., 2015, Proceedings - Frontiers in Education Conference, FIE, 2015 - February, P1
[2]  
[Anonymous], 2016, 2016 IEEE 2 ANN SO P
[3]   Comparison of Secondary Arcs for Reclosing Applications [J].
Dias, O. ;
Magrin, F. ;
Tavares, M. C. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (03) :1592-1599
[4]   Implementation and Application of Practical Traveling-Wave-Based Directional Protection in UHV Transmission Lines [J].
Dong, Xinzhou ;
Luo, Shuxin ;
Shi, Shenxing ;
Wang, Bin ;
Wang, Shiyong ;
Ren, Li ;
Xu, Fei .
IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (01) :294-302
[5]   Dynamic Analysis of MMC-Based MTDC Grids: Use of MMC Energy to Improve Voltage Behavior [J].
Freytes, Julian ;
Akkari, Samy ;
Rault, Pierre ;
Belhaouane, Mohamed Moez ;
Gruson, Francois ;
Colas, Frederic ;
Guillaud, Xavier .
IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (01) :137-148
[6]   Transient Characteristics Under Ground and Short-Circuit Faults in a ±500 kV MMC-Based HVDC System With Hybrid DC Circuit Breakers [J].
Han, Xue ;
Sima, Wenxia ;
Yang, Ming ;
Li, Licheng ;
Yuan, Tao ;
Si, Yan .
IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (03) :1378-1387
[7]  
Kundur P., 1994, Power System Stability and Control
[8]   A Pole-to-Pole Short-Circuit Fault Current Calculation Method for DC Grids [J].
Li, Chengyu ;
Zhao, Chengyong ;
Xu, Jianzhong ;
Ji, Yuke ;
Zhang, Fan ;
An, Ting .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (06) :4943-4953
[9]  
Mao Ji, 2019, 2019 IEEE Innovative Smart Grid Technologies - Asia (ISGT Asia), P2282, DOI 10.1109/ISGT-Asia.2019.8880904
[10]  
Ohnuki S, 2016, 2016 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS), P1786, DOI 10.1109/PIERS.2016.7734795