Wireless Bi-directional Data Link for an EEG Recording System using STM32

被引:0
作者
Vaithianathan, Tamilkavitha [1 ]
Zhou, Haiyan [1 ]
Hauer, Johann [1 ]
机构
[1] Fraunhofer Inst Integrated Circuits, D-91058 Erlangen, Germany
来源
2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) | 2014年
关键词
Wireless implant; RF; STM32; EEG; ASIC; POWER;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A wireless bi-directional data link for an electroencephalogram (EEG) recording system is presented in this paper. The system is mainly composed of a prototype model of an implant and a data recorder. Both the implant and the data recorder use STM32 microcontrollers with an inbuilt radio frequency (RF) transceiver to establish a wireless link between them. The main component of the implant is a mixed-signal EEG acquisition ASIC with 8 channels. The STM32 and the ASIC of the implant module communicate via two SPI interfaces. Optimized software codes for the STM32 microcontrollers have been written to ensure a reliable wireless communication between the implant and the data recorder. A PC is connected to the data recorder which enables the communication by sending the configuration data to the implant. The data received by the data recorder is stored in a PC. The amount of input referred noise of the ASIC present in the output is estimated with the help of MATLAB.
引用
收藏
页码:401 / 405
页数:5
相关论文
共 8 条
  • [1] A Business Intelligent Model for Market Risk Measurement
    Chen, Xiaoliang
    Lai, Kin Keung
    [J]. ICNC 2008: FOURTH INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION, VOL 7, PROCEEDINGS, 2008, : 3 - 7
  • [2] Microcontroller-based wireless recorder for biomedical signals
    Chien, C. -N.
    Hsu, H. -W.
    Jang, J. -K.
    Rau, C. -L.
    Jaw, F. -S.
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 5179 - 5181
  • [3] Rui-Feng Xue, 2011, 2011 International Symposium on Integrated Circuits (ISIC 2011), P144, DOI 10.1109/ISICir.2011.6131898
  • [4] A Power and Data Link for a Wireless-Implanted Neural Recording System
    Rush, Alexander D.
    Troyk, Philip R.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (11) : 3255 - 3262
  • [5] The Design of a Bi-directional, RFID-based ASIC for Interfacing with SPI Bus Peripherals
    Turner, Matthew
    Naber, John
    [J]. 53RD IEEE INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, 2010, : 554 - 557
  • [6] A Low-Power 32-Channel Digitally Programmable Neural Recording Integrated Circuit
    Wattanapanitch, Woradorn
    Sarpeshkar, Rahul
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2011, 5 (06) : 592 - 602
  • [7] Zhang Haifeng, 2011, 2011 International Conference on Multimedia Technology, P832
  • [8] Zhou HY, 2012, IEEE I C ELECT CIRC, P649, DOI 10.1109/ICECS.2012.6463642