Correlation of maximum flexion with clinical outcome after total knee replacement in Asian patients

被引:83
作者
Park, K. K. [1 ]
Chang, C. B. [1 ]
Kang, Y. G. [1 ]
Seong, S. C. [1 ]
Kim, T. K. [1 ]
机构
[1] Seoul Natl Univ, Joint Reconstruct Ctr, Bundang Hosp, Seoul 463707, South Korea
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2007年 / 89B卷 / 05期
关键词
D O I
10.1302/0301-620X.89B5.18117
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study aimed to determine the correlation between the amount of maximum flexion and the clinical outcome in 207 Koreans (333 knees) undergoing total knee replacement. The association of maximum flexion with clinical outcome was evaluated one year post-operatively using three scoring systems; the American Knee Society score, Western Ontario McMaster Universities Osteoarthritis index and the Short Form-36. The mean maximum flexion decreased post-operatively at 12 months from 140.1 degrees (60 degrees to 160 degrees) to 133.0 degrees (105 degrees to 150). Only the social function score of the Short Form-36 correlated significantly with maximum flexion (correlation coefficient = 0.180, p = 0.039). In comparative analyses of subgroups divided by a maximum flexion of 120, we found no significant differences in any parameters except the social function score of the Short Form-36 (41.9 vs 47.3, p = 0.031). Knees with a maximum flexion of more than 135 had a better functional Western Ontario McMasters Universities Osteoarthritis index score than knees with maximum flexion of 135 degrees or less (17.5 vs 14.3, p = 0.031). We found only weak correlation between the postoperative maximum flexion and the clinical parameters for pain relief, function and quality of life, even in Korean patients. Efforts to increase post-operative maximum flexion should be exercised with caution until concerns relating to high-flexion activities are sufficiently resolved.
引用
收藏
页码:604 / 608
页数:5
相关论文
共 31 条
[1]   Comparison of mobile-bearing and fixed-bearing total knee arthroplasty - A prospective randomized study [J].
Aglietti, P ;
Baldini, A ;
Buzzi, R ;
Lup, D ;
De Luca, L .
JOURNAL OF ARTHROPLASTY, 2005, 20 (02) :145-153
[2]   The influence of an anterior-posterior gliding mobile bearing on range of motion after total knee arthroplasty - A prospective, randomized, double-blinded study [J].
Aigner, C ;
Windhager, R ;
Pechmann, M ;
Rehak, P ;
Engeleke, K .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (10) :2257-2262
[3]  
Alicea J., 2001, Surgery of the Knee, VVolume 2, P1507
[4]   A high flexion total knee arthroplasty design replicates healthy knee motion [J].
Argenson, JNA ;
Komistek, RD ;
Mahfouz, M ;
Walker, SA ;
Aubaniac, JM ;
Dennis, DA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :174-179
[5]   In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty [J].
Argenson, JNA ;
Scuderi, GR ;
Komistek, RD ;
Scott, WN ;
Kelly, MA ;
Aubaniac, JM .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :277-284
[6]   Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties [J].
Banks, S ;
Bellemans, J ;
Nozaki, H ;
Whiteside, LA ;
Harman, M ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :131-138
[7]  
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[8]   The influence of tibial slope on maximal flexion after total knee arthroplasty [J].
Bellemans, J ;
Robijns, F ;
Duerinckx, J ;
Banks, S ;
Vandenneucker, H .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (03) :193-196
[9]   Range of motion after total knee arthroplasty - The effect of implant design and weight-bearing conditions [J].
Dennis, DA ;
Komistek, RD ;
Stiehl, JB ;
Walker, SA ;
Dennis, KN .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :748-752
[10]   Observed kneeling ability after total, unicompartmental and patellofemoral knee arthroplasty: perception versus reality [J].
Hassaballa, MA ;
Porteous, AJ ;
Newman, JH .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2004, 12 (02) :136-139