共 50 条
Strain Elastography-Targeted Biopsy: Does Prostate Volume Affect Prostate Cancer Detaction?
被引:2
作者:
Zhu, Yi-Cheng
[1
]
Shan, Jun
[1
]
Zhang, Yuan
[1
]
Jiang, Quan
[1
]
Wang, Yong-Bing
[2
]
Deng, Shu-Hao
[1
]
Qu, Qing-Hua
[3
]
Li, Qing
[4
]
机构:
[1] Shanghai Univ Med & Hlth Sci, Pudong New Area Peoples Hosp, Dept Ultrasound, Shanghai, Peoples R China
[2] Shanghai Univ Med & Hlth Sci, Pudong New Area Peoples Hosp, Dept Gen Surg, Shanghai, Peoples R China
[3] Shanghai Univ Med & Hlth Sci, Pudong New Area Peoples Hosp, Dept Urol, Shanghai, Peoples R China
[4] Shanghai Univ Med & Hlth Sci, Pudong New Area Peoples Hosp, Dept Pathol, Shanghai, Peoples R China
来源:
MEDICAL SCIENCE MONITOR
|
2019年
/
25卷
关键词:
Elasticity Imaging Techniques;
Image-Guided Biopsy;
Prostatic Neoplasms;
Ultrasonography;
REAL-TIME ELASTOGRAPHY;
FUSION-GUIDED BIOPSY;
DIAGNOSIS;
ULTRASONOGRAPHY;
STIFFNESS;
IMPROVE;
D O I:
10.12659/MSM.917344
中图分类号:
R-3 [医学研究方法];
R3 [基础医学];
学科分类号:
1001 ;
摘要:
Background: The present study aimed to assess the correlation between prostate volume and prostate cancer (PCa) detection by strain elastography (SE)-guided targeted biopsy (TB) compared with conventional transrectal ultrasound (TRUS)-guided systematic biopsy (SB). Material/Methods: This retrospective study enrolled 357 patients suspected to have PCa. All patients received TRUS-guided 10-core SB and SE-guided TB. The sensitivity for PCa detected by SE-guided TB was compared with that by TRUS-guided SB, in combination with prostate biopsy pathology. The correlation between the prostate volume and the detection rate of SE-guided TB was investigated. Results: PCa was pathologically confirmed in 151 out of 357 patients. The by-patient detection rate of TRUS-guided SB was 72.8% (110/151). Subsequently, a further increase of 6.6% (10/151) in PCa determination was obtained by the SE-guided TB. The sensitivity of SE-guided TB for patients with prostate volume <30 ml, 30-50 ml, 51-80 ml, and >80 ml was 91.7% (44/48), 80.3% (53/66), 70.4% (19/27), and 40.0% (4/10), respectively (p=0.002). For patients with a prostate volume less than 30 ml, SE-guided TB (91.7%) had a higher sensitivity than SB (62.5%) (p<0.007). Conclusions: SE-guided TB has a higher detection rate of PCa in comparison with TRUS-guided SB. There was also a negative correlation between prostate volume and SE-guided TB. Therefore, use of SE-guided TB may complement use of conventional SB, especially for patients with smaller prostate volume.
引用
收藏
页码:8836 / 8842
页数:7
相关论文
共 50 条