Strain Elastography-Targeted Biopsy: Does Prostate Volume Affect Prostate Cancer Detaction?

被引:2
作者
Zhu, Yi-Cheng [1 ]
Shan, Jun [1 ]
Zhang, Yuan [1 ]
Jiang, Quan [1 ]
Wang, Yong-Bing [2 ]
Deng, Shu-Hao [1 ]
Qu, Qing-Hua [3 ]
Li, Qing [4 ]
机构
[1] Shanghai Univ Med & Hlth Sci, Pudong New Area Peoples Hosp, Dept Ultrasound, Shanghai, Peoples R China
[2] Shanghai Univ Med & Hlth Sci, Pudong New Area Peoples Hosp, Dept Gen Surg, Shanghai, Peoples R China
[3] Shanghai Univ Med & Hlth Sci, Pudong New Area Peoples Hosp, Dept Urol, Shanghai, Peoples R China
[4] Shanghai Univ Med & Hlth Sci, Pudong New Area Peoples Hosp, Dept Pathol, Shanghai, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2019年 / 25卷
关键词
Elasticity Imaging Techniques; Image-Guided Biopsy; Prostatic Neoplasms; Ultrasonography; REAL-TIME ELASTOGRAPHY; FUSION-GUIDED BIOPSY; DIAGNOSIS; ULTRASONOGRAPHY; STIFFNESS; IMPROVE;
D O I
10.12659/MSM.917344
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The present study aimed to assess the correlation between prostate volume and prostate cancer (PCa) detection by strain elastography (SE)-guided targeted biopsy (TB) compared with conventional transrectal ultrasound (TRUS)-guided systematic biopsy (SB). Material/Methods: This retrospective study enrolled 357 patients suspected to have PCa. All patients received TRUS-guided 10-core SB and SE-guided TB. The sensitivity for PCa detected by SE-guided TB was compared with that by TRUS-guided SB, in combination with prostate biopsy pathology. The correlation between the prostate volume and the detection rate of SE-guided TB was investigated. Results: PCa was pathologically confirmed in 151 out of 357 patients. The by-patient detection rate of TRUS-guided SB was 72.8% (110/151). Subsequently, a further increase of 6.6% (10/151) in PCa determination was obtained by the SE-guided TB. The sensitivity of SE-guided TB for patients with prostate volume <30 ml, 30-50 ml, 51-80 ml, and >80 ml was 91.7% (44/48), 80.3% (53/66), 70.4% (19/27), and 40.0% (4/10), respectively (p=0.002). For patients with a prostate volume less than 30 ml, SE-guided TB (91.7%) had a higher sensitivity than SB (62.5%) (p<0.007). Conclusions: SE-guided TB has a higher detection rate of PCa in comparison with TRUS-guided SB. There was also a negative correlation between prostate volume and SE-guided TB. Therefore, use of SE-guided TB may complement use of conventional SB, especially for patients with smaller prostate volume.
引用
收藏
页码:8836 / 8842
页数:7
相关论文
共 50 条
  • [41] Transperineal Magnetic Resonance Image Targeted Prostate Biopsy Versus Transperineal Template Prostate Biopsy in the Detection of Clinically Significant Prostate Cancer
    Labanaris, Apostolos P.
    JOURNAL OF UROLOGY, 2013, 189 (03) : 866 - 866
  • [42] Shear Wave Elastography for Detection of Prostate Cancer: A Preliminary Study
    Woo, Sungmin
    Kim, Sang Youn
    Cho, Jeong Yeon
    Kim, Seung Hyup
    KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (03) : 346 - 355
  • [43] Targeted Biopsy to Detect Gleason Score Upgrading during Active Surveillance for Men with Low versus Intermediate Risk Prostate Cancer
    Nassiri, Nima
    Margolis, Daniel J.
    Natarajan, Shyam
    Sharma, Devi S.
    Huang, Jiaoti
    Dorey, Frederick J.
    Marks, Leonard S.
    JOURNAL OF UROLOGY, 2017, 197 (03) : 632 - 639
  • [44] Learning curve for fusion magnetic resonance imaging targeted prostate biopsy and three-dimensional transrectal ultrasonography segmentation
    Lenfant, Louis
    Beitone, Clement
    Troccaz, Jocelyne
    Roupret, Morgan
    Seisen, Thomas
    Voros, Sandrine
    Mozer, Pierre C.
    BJU INTERNATIONAL, 2024, 133 (06) : 709 - 716
  • [45] Impact of prostate volume on the active surveillance in prostate cancer
    Beaujouan, Florent
    Bertherat, Walter
    Hammoudi, Zakaria
    Chicaud, Marie
    Descazeaud, Aurelien
    JOURNAL OF CLINICAL UROLOGY, 2024,
  • [46] Magnetic resonance imaging detection of prostate cancer in men with previous negative prostate biopsy
    Truong, Matthew
    Frye, Thomas P.
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2017, 6 (03) : 424 - 431
  • [47] Targeted Biopsy in the Detection of Prostate Cancer Using an Office Based Magnetic Resonance Ultrasound Fusion Device
    Wood, Bradford J.
    Choyke, Peter
    Turkbey, Baris
    Pinto, Peter
    JOURNAL OF UROLOGY, 2013, 189 (01) : 92 - 92
  • [48] Modern aspects of targeted prostate biopsy
    Popov, S., V
    Orlov, I. N.
    Malevich, S. M.
    Sushina, I., V
    Grin', E. A.
    Gulko, A. M.
    Topuzov, T. M.
    Vyazovtsev, P. V.
    Chernysheva, D. Yu
    Neradovskiy, V. A.
    ONKOUROLOGIYA, 2021, 17 (01): : 153 - 158
  • [49] Prediction of Significant Prostate Cancer at Prostate Biopsy and Per Core Detection Rate of Targeted and Systematic Biopsies Using Real-Time Shear Wave Elastography
    Boehm, Katharina
    Budaeus, Lars
    Tennstedt, Pierre
    Beyer, Burkhard
    Schiffmann, Jonas
    Larcher, Alessandro
    Simonis, Kathrin
    Graefen, Markus
    Beyersdorff, Dirk
    Salomon, Georg
    UROLOGIA INTERNATIONALIS, 2015, 95 (02) : 189 - 196
  • [50] Operator is an Independent Predictor of Detecting Prostate Cancer at Transrectal Ultrasound Guided Prostate Biopsy
    Lawrentschuk, Nathan
    Toi, Ants
    Lockwood, Gina A.
    Evans, Andrew
    Finelli, Antonio
    O'Malley, Martin
    Margolis, Myles
    Ghai, Sangeet
    Fleshner, Neil E.
    JOURNAL OF UROLOGY, 2009, 182 (06) : 2659 - 2663