Strain Elastography-Targeted Biopsy: Does Prostate Volume Affect Prostate Cancer Detaction?

被引:2
|
作者
Zhu, Yi-Cheng [1 ]
Shan, Jun [1 ]
Zhang, Yuan [1 ]
Jiang, Quan [1 ]
Wang, Yong-Bing [2 ]
Deng, Shu-Hao [1 ]
Qu, Qing-Hua [3 ]
Li, Qing [4 ]
机构
[1] Shanghai Univ Med & Hlth Sci, Pudong New Area Peoples Hosp, Dept Ultrasound, Shanghai, Peoples R China
[2] Shanghai Univ Med & Hlth Sci, Pudong New Area Peoples Hosp, Dept Gen Surg, Shanghai, Peoples R China
[3] Shanghai Univ Med & Hlth Sci, Pudong New Area Peoples Hosp, Dept Urol, Shanghai, Peoples R China
[4] Shanghai Univ Med & Hlth Sci, Pudong New Area Peoples Hosp, Dept Pathol, Shanghai, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2019年 / 25卷
关键词
Elasticity Imaging Techniques; Image-Guided Biopsy; Prostatic Neoplasms; Ultrasonography; REAL-TIME ELASTOGRAPHY; FUSION-GUIDED BIOPSY; DIAGNOSIS; ULTRASONOGRAPHY; STIFFNESS; IMPROVE;
D O I
10.12659/MSM.917344
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The present study aimed to assess the correlation between prostate volume and prostate cancer (PCa) detection by strain elastography (SE)-guided targeted biopsy (TB) compared with conventional transrectal ultrasound (TRUS)-guided systematic biopsy (SB). Material/Methods: This retrospective study enrolled 357 patients suspected to have PCa. All patients received TRUS-guided 10-core SB and SE-guided TB. The sensitivity for PCa detected by SE-guided TB was compared with that by TRUS-guided SB, in combination with prostate biopsy pathology. The correlation between the prostate volume and the detection rate of SE-guided TB was investigated. Results: PCa was pathologically confirmed in 151 out of 357 patients. The by-patient detection rate of TRUS-guided SB was 72.8% (110/151). Subsequently, a further increase of 6.6% (10/151) in PCa determination was obtained by the SE-guided TB. The sensitivity of SE-guided TB for patients with prostate volume <30 ml, 30-50 ml, 51-80 ml, and >80 ml was 91.7% (44/48), 80.3% (53/66), 70.4% (19/27), and 40.0% (4/10), respectively (p=0.002). For patients with a prostate volume less than 30 ml, SE-guided TB (91.7%) had a higher sensitivity than SB (62.5%) (p<0.007). Conclusions: SE-guided TB has a higher detection rate of PCa in comparison with TRUS-guided SB. There was also a negative correlation between prostate volume and SE-guided TB. Therefore, use of SE-guided TB may complement use of conventional SB, especially for patients with smaller prostate volume.
引用
收藏
页码:8836 / 8842
页数:7
相关论文
共 50 条
  • [21] Transrectal real-time tissue elastography targeted biopsy coupled with peak strain index improves the detection of clinically important prostate cancer
    Ma, Qi
    Yang, Dong-Rong
    Xue, Bo-Xin
    Wang, Cheng
    Chen, Han-Bin
    Dong, Yun
    Wang, Cai-Shan
    Shan, Yu-Xi
    ONCOLOGY LETTERS, 2017, 14 (01) : 210 - 216
  • [22] Additional elastography-targeted biopsy improves the agreement between biopsy Gleason grade and Gleason grade at radical prostatectomy
    Boehm, Katharina
    Tennstedt, Pierre
    Beyer, Burkhard
    Schiffmann, Jonas
    Beckmann, Ann
    Michl, Uwe
    Beyersdorff, Dirk
    Budaeus, Lars
    Graefen, Markus
    Karakiewicz, Pierre I.
    Salomon, Georg
    WORLD JOURNAL OF UROLOGY, 2016, 34 (06) : 805 - 810
  • [23] Comparison of contrast enhanced color Doppler targeted biopsy with conventional systematic biopsy: Impact on prostate cancer detection
    Frauscher, F
    Klauser, A
    Volgger, H
    Halpern, EJ
    Pallwein, L
    Steiner, H
    Schuster, A
    Horninger, W
    Rogatsch, H
    Bartsch, G
    JOURNAL OF UROLOGY, 2002, 167 (04) : 1648 - 1652
  • [24] Individualization of the biopsy protocol according to the prostate gland volume for prostate cancer detection
    Eskicorapci, SY
    Guliyev, F
    Akdogan, B
    Dogan, HS
    Ergen, A
    Ozen, H
    JOURNAL OF UROLOGY, 2005, 173 (05) : 1536 - 1540
  • [25] The relationship of prostate gland volume to extended needle biopsy on prostate cancer detection
    Ung, JO
    San Francisco, IF
    Regan, MM
    DeWolf, WC
    Olumi, AF
    JOURNAL OF UROLOGY, 2003, 169 (01) : 130 - 135
  • [26] Shear Wave Elastography for Localization of Prostate Cancer Lesions and Assessment of Elasticity Thresholds: Implications for Targeted Biopsies and Active Surveillance Protocols
    Boehm, Katharina
    Salomon, Georg
    Beyer, Burkhard
    Schiffmann, Jonas
    Simonis, Kathrin
    Graefen, Markus
    Budaeus, Lars
    JOURNAL OF UROLOGY, 2015, 193 (03) : 794 - 800
  • [27] Can we improve the detection rate of prostate cancer using standard 12-core TRUS-guided prostate biopsy? Focused on the location of prostate biopsy
    Yoo, Sangjun
    Suh, Jungyo
    Park, Juhyun
    Cho, Min Chul
    Son, Hwancheol
    Jeong, Hyeon
    CANCER MEDICINE, 2020, 9 (11): : 3758 - 3764
  • [28] Evaluation of the Prostate Imaging Reporting and Data System for the Detection of Prostate Cancer by the Results of Targeted Biopsy of the Prostate
    Baur, Alexander D. J.
    Maxeiner, Andreas
    Franiel, Tobias
    Kilic, Ergin
    Huppertz, Alexander
    Schwenke, Carsten
    Hamm, Bernd
    Durmus, Tahir
    INVESTIGATIVE RADIOLOGY, 2014, 49 (06) : 411 - 420
  • [29] The role of targeted biopsy methods in the prostate cancer diagnosis
    Petov, V. S.
    Sapelko, A., V
    Danilov, S. P.
    Chernov, Ya N.
    Taratkin, M. S.
    Amosov, A., V
    Enikeev, D., V
    Krupinov, G. E.
    ONKOUROLOGIYA, 2021, 17 (02): : 157 - 167
  • [30] Prostate Atypia: Does Repeat Biopsy Detect Clinically Significant Prostate Cancer?
    Dorin, Ryan P.
    Wiener, Scott
    Harris, Cory D.
    Wagner, Joseph R.
    PROSTATE, 2015, 75 (07) : 673 - 678