Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

被引:0
作者
Medhat, M. E. [1 ,2 ]
Singh, V. P. [3 ,4 ]
机构
[1] Nucl Res Ctr, Expt Nucl Phys Dept, PO 13759, Cairo, Egypt
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[3] Karnatak Univ, Dept Phys, Dharwad 580003, Karnataka, India
[4] NPCIL, Kaiga Atom Power Stn 3&4, Hlth Phys Sect, Karwar 581400, India
关键词
Composite material; Mass attenuation coefficient; Geant4; simulations; ATTENUATION COEFFICIENTS; TOOLKIT;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In the present work, the applicability of Geant4 Monte Carlo code for mass attenuations of different types of composite materials such as building materials, glasses, plastics and water matrix at photon energies 59.5, 80, 356, 661.6, 1173.2 and 1332.5 keV has been tested. The Geant4 simulated results of mass attenuation coefficients of composite materials have been compared with the experimental and theoretical XCOM data and a good agreement has been observed. The results indicate that this simulation process can be followed to determine the data on the gamma rays interaction parameters with the several energies in different types of materials. The modeling for photon interaction has been standardarised for any type of composite samples. The Geant4 code can be utilized for gamma ray mass attenuation coefficients for each sample at different energies, which may sometimes be impractical by experiment investigation.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 10 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Geant4 developments and applications [J].
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Dubois, PA ;
Asai, M ;
Barrand, G ;
Capra, R ;
Chauvie, S ;
Chytracek, R ;
Cirrone, GAP ;
Cooperman, G ;
Cosmo, G ;
Cuttone, G ;
Daquino, GG ;
Donszelmann, M ;
Dressel, M ;
Folger, G ;
Foppiano, F ;
Generowicz, J ;
Grichine, V ;
Guatelli, S ;
Gumplinger, P ;
Heikkinen, A ;
Hrivnacova, I ;
Howard, A ;
Incerti, S ;
Ivanchenko, V ;
Johnson, T ;
Jones, F ;
Koi, T ;
Kokoulin, R ;
Kossov, M ;
Kurashige, H ;
Lara, V ;
Larsson, S ;
Lei, F ;
Link, O ;
Longo, F ;
Maire, M ;
Mantero, A ;
Mascialino, B ;
McLaren, I ;
Lorenzo, PM ;
Minamimoto, K ;
Murakami, K ;
Nieminen, P ;
Pandola, L ;
Parlati, S ;
Peralta, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :270-278
[3]   Comparison of Geant4 electromagnetic physics models against the NIST reference data [J].
Amako, K ;
Guatelli, S ;
Ivanchenko, VN ;
Maire, M ;
Mascialino, B ;
Murakami, K ;
Nieminen, P ;
Pandola, L ;
Parlati, S ;
Pia, MG ;
Piergentili, M ;
Sasaki, T ;
Urban, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) :910-918
[4]   Validation of the Geant4 electromagnetic photon cross-sections for elements and compounds [J].
Cirrone, G. A. P. ;
Cuttone, G. ;
Di Rosa, F. ;
Pandola, L. ;
Romano, F. ;
Zhang, Q. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 618 (1-3) :315-322
[5]   Review and history of photon cross section calculations [J].
Hubbell, J. H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13) :R245-R262
[6]   Geant4 code for simulation attenuation of gamma rays through scintillation detectors [J].
Medhat, M. E. ;
Wang, Yifang .
ANNALS OF NUCLEAR ENERGY, 2013, 62 :316-320
[7]   Study of the mass attenuation coefficients and effective atomic numbers in some gemstones [J].
Medhat, M. E. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 293 (02) :555-564
[8]   Application of gamma-ray transmission method for study the properties of cultivated soil [J].
Medhat, M. E. .
ANNALS OF NUCLEAR ENERGY, 2012, 40 (01) :53-59
[9]   Studies on effective atomic numbers and electron densities in different solid state track detectors in the energy range 1 keV-100 GeV [J].
Medhat, M. E. .
ANNALS OF NUCLEAR ENERGY, 2011, 38 (06) :1252-1263
[10]   Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study [J].
Singh, Vishwanath P. ;
Medhat, M. E. ;
Badiger, N. M. .
ANNALS OF NUCLEAR ENERGY, 2014, 68 :96-100