Experimental analysis of dummy load prototype for ITER coil power supply system

被引:1
作者
Li Chuan [1 ]
Song Zhiquan [2 ]
Luo Bin [1 ]
Li Jiawei [1 ]
Qin Xiuqi [3 ]
Zhu Guangliang [4 ]
Fu Peng [2 ]
Zhang Xiuqing [2 ]
Li Hua [2 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, Int Joint Res Lab Magnet Confinement Fus & Plasma, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[3] Anhui Elect Power Design Inst, Hefei 230601, Anhui, Peoples R China
[4] Hefei Keye Electrophys Equipment Mfg Co Ltd, Hefei 230031, Anhui, Peoples R China
关键词
ITER; Dummy load; Large inductance; Experimental analysis; Finite element analysis; AC/DC CONVERTER; DC REACTOR; DESIGN;
D O I
10.1016/j.fusengdes.2019.02.004
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This paper basically introduces the experimental analysis of the dummy load prototype, which aims to verify the capability of the ITER magnetic power supply systems to operate at their rated power levels without energizing the superconducting coils. The rated inductance of dummy load is 6.73mH and the pulse test currents are 45 kA, 55 kA and 68 kA. According to the requirements of the large inductance and different pulse test current classes, a dry-type air-core water-cooling prototype with epoxy resin casting technique has been fabricated, which has 24 layers and 72 turns. The experimental analyses, including the consistency test, inductance test, and temperature rise test are described in detail. The consistency of different coil layer is ensured by comparing the voltage wave under the same voltage excitation. The inductance test includes dc inductance test by using the first order circuit method and ac inductance test by LCR instrument and finite element simulation analysis. The temperature rise test results under different current classes are introduced by comparing with the simulation analyses. The above experimental results are coincided with the requirements, which shows the feasibility and availability of the prototype.
引用
收藏
页码:1064 / 1068
页数:5
相关论文
共 50 条
[21]   Non-Characteristic Harmonics Analysis of the ITER Pulsed Power Supply [J].
杨威 ;
许留伟 ;
傅鹏 ;
卢华伟 ;
盛志才 .
Plasma Science and Technology, 2009, (04) :493-498
[22]   PRELIMINARY SYSTEM DESIGN AND ANALYSIS OF AN OPTIMIZED INFRASTRUCTURE FOR ITER PROTOTYPE CRYOLINE TEST [J].
Shah, N. ;
Bhattacharya, R. ;
Sarkar, B. ;
Badgujar, S. ;
Vaghela, H. ;
Patel, P. .
ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 :1935-1942
[23]   R&D Progress of 1 MV Power Supply System for ITER [J].
Tobari, H. ;
Watanabe, K. ;
Kashiwagi, M. ;
Yamanaka, H. ;
Maejima, T. ;
Terunuma, Y. ;
Kojima, A. ;
Dairaku, M. ;
Hanada, M. .
2015 IEEE 26TH SYMPOSIUM ON FUSION ENGINEERING (SOFE), 2015,
[24]   Experimental proof of a load resilient external matching solution for the ITER ICRH system [J].
Vervier, M ;
Messiaen, A ;
Dumortier, P ;
Lamalle, P .
Radio Frequency Power in Plasmas, 2005, 787 :202-205
[25]   Experimental analysis of the inserted waveguide CVD diamond window prototype for the ITER ECRH upper launcher [J].
Scherer, T. A. ;
Meier, A. ;
Strauss, D. ;
Schreck, S. ;
Takahashi, K. ;
Kajiwara, K. ;
Oda, Y. ;
Sakamoto, K. ;
Saibene, G. .
2011 36TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2011,
[26]   Seismic analysis under SL-1 of high-power DC reactor prototype for ITER poloidal field converter [J].
Li, Chuan ;
Yang, Yong ;
Liao, Yuanxu ;
Zhang, Ming ;
Song, Zhiquan ;
Fu, Peng .
FUSION ENGINEERING AND DESIGN, 2017, 124 :153-158
[27]   A Dummy Load for Tester Stand-Alone Photovoltaic 5 kWp with the Maximum Power Tracking System [J].
Watanakul, Narin ;
Pattanasethanon, Singthong .
INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (01) :167-172
[28]   A Maximum Current Control Method for Three-Phase PWM Rectifier for the ITER In-Vessel Vertical Stability Coil Power Supply [J].
Qian, Kun ;
Gao, Ge ;
Sheng, Zhicai .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (05) :1689-1693
[29]   Coil misalignment analysis under different radius of coil and wire for Wireless Power Transfer System [J].
Mude, K. N. ;
Outeiro, M. T. .
IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, :5319-5323
[30]   The analysis of use of typical load schedules when the design or analysis of power supply systems [J].
Trunova, Iryna ;
Miroshnyk, Oleksandr ;
Moroz, Oleksandr ;
Pazyi, Volodymyr ;
Sereda, Anatolii ;
Dudnikov, Serhii .
2020 IEEE KHPI WEEK ON ADVANCED TECHNOLOGY (KHPI WEEK), 2020, :61-64