Experimental investigations on single-phase heat transfer enhancement with longitudinal vortices in narrow rectangular channel

被引:57
作者
Ma, Jian [1 ]
Huang, Yan Ping [1 ]
Huang, Jun [1 ,2 ]
Wang, Yan Lin [1 ]
Wang, Qiu Wang [2 ]
机构
[1] Nucl Power Inst China, Key Lab Bubble Phys & Nat Circulat, Chengdu 610041, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
关键词
UNSTEADY-FLOW;
D O I
10.1016/j.nucengdes.2009.10.015
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Four pairs of rectangular block as longitudinal vortex generators (LVG) were mounted periodically in a narrow rectangular channel to investigate fluid flow and convective heat transfer respectively in the narrow rectangular channel with LVG and without LVG. Both the channels have the same narrow gap (d) = 3 mm, the same hydraulic diameter (D-h) = 5.58 mm and the same length to diameter ratio (L/D-h) = 80.65. The experiments were performed with the channels oriented uprightly and uniform heat fluxes applied at the one side of the heating plate and single-phase water was used as test fluid. The parameters that were varied during the experiments included the mass flow rate, inlet liquid temperature, system pressure, and heat flux. In each of the experiments conducted, the temperature of both the liquid and the wall was measured at various locations along the flow direction. Based on the measured temperatures and the overall energy balance across the test section, the heat transfer coefficients for single-phase forced convection have been calculated. At the same time, in these experiments, the single-phase pressure drop across the channels was also measured. The correlations have been developed for mean Nusselt numbers and friction factors. Additionally, the visual experiments of infrared thermo-image recording the temperature on the outer wall of the heating plate have been conducted for validating the effects of LV. In these experimental investigations, both laminar regime and turbulent regime were under the thermo-hydraulic developing conditions, laminar-to-turbulent transition occurred in advance with the help of LV when Reynolds numbers vary between 310 and 4220. In laminar regime, LV causes heat transfer enhancement of about 100.9% and flow resistance increase of only 11.4%. And in turbulent regime, LV causes heat transfer enhancement of above 87.1% and flow resistance increase of 100.3%. As a result, LV can obviously enhance heat transfer of single-phase water, and increase flow resistance mildly. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 102
页数:11
相关论文
共 17 条
[1]   The fluid mechanics of microdevices - The Freeman Scholar Lecture [J].
Gad-el-Hak, M .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (01) :5-33
[2]  
HUANG YP, 2005, 50576089 NUCL POW I
[3]   Experimental study on heat transfer augmentation for high heat flux removal in rib-roughened narrow channels [J].
Islam, MS ;
Hino, R ;
Haga, K ;
Monde, M ;
Sudo, Y .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1998, 35 (09) :671-678
[4]  
Jia L., 2003, Advanced Heat Transfer, Vsecond
[5]  
Kays W.M., 1953, 17 TR STANF U DEP ME
[6]  
LIU Y, 2007, ENG THERMAL PHYS T, V28, P92
[7]  
MA J, 2008, INVESTIGATION HEAT T
[8]  
QIU SZ, 2006, INVESTIGATIONS SATUR
[9]  
Shah R.K., 1978, ADV HEAT TRANSFER
[10]   Heat transfer in rectangular channels with transverse and V-shaped broken ribs [J].
Tanda, G .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (02) :229-243