Mechanical Circulatory Support Devices for Acute Right Ventricular Failure

被引:250
作者
Kapur, Navin K. [1 ]
Esposito, Michele L. [1 ]
Bader, Yousef [1 ]
Morine, Kevin J. [1 ]
Kiernan, Michael S. [1 ]
Duc Thinh Pham [2 ]
Burkhoff, Daniel [3 ]
机构
[1] Tufts Med Ctr, Cardiovasc Ctr, 800 Washington St,Box 80, Boston, MA 02111 USA
[2] Northwestern Univ, Med Ctr, Dept Cardiac Surg, Chicago, IL 60611 USA
[3] Cardiovasc Res Fdn, New York, NY USA
关键词
assisted circulation; hemodynamics; ventricular dysfunction; right; EXTRACORPOREAL MEMBRANE-OXYGENATION; RIGHT HEART-FAILURE; INFERIOR MYOCARDIAL-INFARCTION; ARTERY PULSATILITY INDEX; SEVERE MITRAL REGURGITATION; ASSIST DEVICE; CARDIOGENIC-SHOCK; PULMONARY-HYPERTENSION; NITRIC-OXIDE; BALLOON COUNTERPULSATION;
D O I
10.1161/CIRCULATIONAHA.116.025290
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Right ventricular (RV) failure remains a major cause of global morbidity and mortality for patients with advanced heart failure, pulmonary hypertension, or acute myocardial infarction and after major cardiac surgery. Over the past 2 decades, percutaneously delivered acute mechanical circulatory support pumps specifically designed to support RV failure have been introduced into clinical practice. RV acute mechanical circulatory support now represents an important step in the management of RV failure and provides an opportunity to rapidly stabilize patients with cardiogenic shock involving the RV. As experience with RV devices grows, their role as mechanical therapies for RV failure will depend less on the technical ability to place the device and more on improved algorithms for identifying RV failure, patient monitoring, and weaning protocols for both isolated RV failure and biventricular failure. In this review, we discuss the pathophysiology of acute RV failure and both the mechanism of action and clinical data exploring the utility of existing RV acute mechanical circulatory support devices.
引用
收藏
页码:314 / 326
页数:13
相关论文
共 100 条
[1]   Current Status of Percutaneous Right Ventricular Assist Devices: First-In-Man Use of a Novel Dual Lumen Cannula [J].
Aggarwal, Vikas ;
Einhorn, Bryce N. ;
Cohen, Howard A. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (03) :390-396
[2]  
Aghili N, 2015, MINERVA CARDIOANGIOL, V63, P75
[3]   Biventricular Circulatory Support Using 2 Axial Flow Catheters for Cardiogenic Shock Without the Need for Surgical Vascular Access [J].
Aghili, Nima ;
Bader, Yousef ;
Vest, Amanda R. ;
Kiernan, Michael S. ;
Kimmelstiel, Carey ;
DeNofrio, David ;
Kapur, Navin K. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (06)
[4]  
Amin Ahmad, 2011, Congest Heart Fail, V17, P288, DOI 10.1111/j.1751-7133.2011.00222.x
[5]   Benefits of a novel percutaneous ventricular assist device for right heart failure: The prospective RECOVER RIGHT study of the Impel la RP device [J].
Anderson, Mark B. ;
Goldstein, James ;
Milano, Carmelo ;
Morris, Lynn D. ;
Kormos, Robert L. ;
Bhama, Jay ;
Kapur, Navin K. ;
Barisal, Aditya ;
Garcia, Jose ;
Baker, Joshua N. ;
Silvestry, Scott ;
Holman, William L. ;
Douglas, Pamela S. ;
O'Neill, William .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (12) :1549-1560
[6]   The Right Ventricle in Health and Disease: Insights into Physiology, Pathophysiology and Diagnostic Management [J].
Apostolakis, Stavros ;
Konstantinides, Stavros .
CARDIOLOGY, 2012, 121 (04) :263-273
[7]   The right heart in heart failure with preserved ejection fraction: insights from cardiac magnetic resonance imaging and invasive haemodynamics [J].
Aschauer, Stefan ;
Kammerlander, Andreas A. ;
Zotter-Tufaro, Caroline ;
Ristl, Robin ;
Pfaffenberger, Stefan ;
Bachmann, Alina ;
Duca, Franz ;
Marzluf, Beatrice A. ;
Bonderman, Diana ;
Mascherbauer, Julia .
EUROPEAN JOURNAL OF HEART FAILURE, 2016, 18 (01) :71-80
[8]   Resuscitation and recovery from acute right ventricular failure using a percutaneous right ventricular assist device [J].
Atiemo, Andrew D. ;
Conte, John V. ;
Heldman, Alan W. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (01) :78-82
[9]  
Atwater Brett D, 2008, J Invasive Cardiol, V20, pE205
[10]   Prolonged use of right ventricular assist device for refractory graft failure following orthotopic heart transplantation [J].
Bajona, Pietro ;
Salizzoni, Stefano ;
Brann, Stacey H. ;
Coyne, Judy ;
Bermudez, Christian ;
Kormos, Robert ;
Toyoda, Yoshiya .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (03) :E53-E54