End-to-end deep learning for interior tomography with low-dose x-ray CT

被引:15
作者
Han, Yoseob [1 ]
Wu, Dufan
Kim, Kyungsang
Li, Quanzheng
机构
[1] Harvard Med Sch, Dept Radiol, Ctr Adv Med Comp & Anal CAMCA, Boston, MA 02115 USA
关键词
low-dose CT; ROI CT; end-to-end learning; deep learning; CONVOLUTIONAL NEURAL-NETWORK; ITERATIVE RECONSTRUCTION; NOISE-REDUCTION; SPARSE; MATRIX; ALGORITHM; FRAMELETS;
D O I
10.1088/1361-6560/ac6560
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. There are several x-ray computed tomography (CT) scanning strategies used to reduce radiation dose, such as (1) sparse-view CT, (2) low-dose CT and (3) region-of-interest (ROI) CT (called interior tomography). To further reduce the dose, sparse-view and/or low-dose CT settings can be applied together with interior tomography. Interior tomography has various advantages in terms of reducing the number of detectors and decreasing the x-ray radiation dose. However, a large patient or a small field-of-view (FOV) detector can cause truncated projections, and then the reconstructed images suffer from severe cupping artifacts. In addition, although low-dose CT can reduce the radiation exposure dose, analytic reconstruction algorithms produce image noise. Recently, many researchers have utilized image-domain deep learning (DL) approaches to remove each artifact and demonstrated impressive performances, and the theory of deep convolutional framelets supports the reason for the performance improvement. Approach. In this paper, we found that it is difficult to solve coupled artifacts using an image-domain convolutional neural network (CNN) based on deep convolutional framelets. Significance. To address the coupled problem, we decouple it into two sub-problems: (i) image-domain noise reduction inside the truncated projection to solve low-dose CT problem and (ii) extrapolation of the projection outside the truncated projection to solve the ROI CT problem. The decoupled sub-problems are solved directly with a novel proposed end-to-end learning method using dual-domain CNNs. Main results. We demonstrate that the proposed method outperforms the conventional image-domain DL methods, and a projection-domain CNN shows better performance than the image-domain CNNs commonly used by many researchers.
引用
收藏
页数:16
相关论文
共 37 条
[1]   Effects of sparse sampling schemes on image quality in low-dose CT [J].
Abbas, Sajid ;
Lee, Taewon ;
Shin, Sukyoung ;
Lee, Rena ;
Cho, Seungryong .
MEDICAL PHYSICS, 2013, 40 (11)
[2]   Iterative reconstruction methods in X-ray CT [J].
Beister, Marcel ;
Kolditz, Daniel ;
Kalender, Willi A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02) :94-108
[3]   Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT [J].
Bian, Junguo ;
Siewerdsen, Jeffrey H. ;
Han, Xiao ;
Sidky, Emil Y. ;
Prince, Jerry L. ;
Pelizzari, Charles A. ;
Pan, Xiaochuan .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22) :6575-6599
[4]   Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network [J].
Chen, Hu ;
Zhang, Yi ;
Kalra, Mannudeep K. ;
Lin, Feng ;
Chen, Yang ;
Liao, Peixi ;
Zhou, Jiliu ;
Wang, Ge .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (12) :2524-2535
[5]   KIKI-net: cross-domain convolutional neural networks for reconstructing undersampled magnetic resonance images [J].
Eo, Taejoon ;
Jun, Yohan ;
Kim, Taeseong ;
Jang, Jinseong ;
Lee, Ho-Joon ;
Hwang, Dosik .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) :2188-2201
[6]  
Han Y., 2017, ARXIV171210248
[7]   One network to solve all ROIs: Deep learning CT for any ROI using differentiated backprojection [J].
Han, Yoseob ;
Ye, Jong Chul .
MEDICAL PHYSICS, 2019, 46 (12) :E855-E872
[8]   Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT [J].
Han, Yoseob ;
Ye, Jong Chul .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (06) :1418-1429
[9]  
Hsieh J, 2004, 2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, P1404
[10]   A novel reconstruction algorithm to extend the CT scan field-of-view [J].
Hsieh, J ;
Chao, E ;
Thibault, J ;
Grekowicz, B ;
Horst, A ;
McOlash, S ;
Myers, TJ .
MEDICAL PHYSICS, 2004, 31 (09) :2385-2391