Partial-volume effect in PET tumor imaging

被引:1191
|
作者
Soret, Marine
Bacharach, Stephen L.
Buvat, Irene
机构
[1] CHU Pitie Salpetriere, INSERM, UMR 678, UPMC, F-75634 Paris 13, France
[2] HIA Val Grace, Dept Nucl Med, Paris, France
[3] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
PET; tumor imaging; partial volume; standardized uptake value;
D O I
10.2967/jnumed.106.035774
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PET has the invaluable advantage of being intrinsically quantitative, enabling accurate measurements of tracer concentrations in vivo. In PET tumor imaging, indices characterizing tumor uptake, such as standardized uptake values, are becoming increasingly important, especially in the context of monitoring the response to therapy. However, when tracer uptake in small tumors is measured, large biases can be introduced by the partial-volume effect (PVE). The purposes of this article are to explain what PVE is and to describe its consequences in PET tumor imaging. The parameters on which PVE depends are reviewed. Actions that can be taken to reduce the errors attributable to PVE are described. Various PVE correction schemes are presented, and their applicability to PETtumor imaging is discussed.
引用
收藏
页码:932 / 945
页数:14
相关论文
共 50 条
  • [1] Partial-Volume Effect and a Partial-Volume Correction for the NanoPET/CT™ Preclinical PET/CT Scanner
    Szanda, Istvan
    Livieratos, Lefteris
    Patay, Gergely
    Tsoumpas, Charalampos
    Sunassee, Kavitha
    Mullen, Gregory E.
    Nemeth, Gabor
    Major, Peter
    Marsden, Paul K.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3605 - 3609
  • [2] Correction of partial-volume effect for PET striatal imaging:: Fast implementation and study of robustness
    Frouin, V
    Comtat, C
    Reilhac, A
    Grégoire, MC
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (12) : 1715 - 1726
  • [3] Assessment of normal aging on partial-volume effect corrected FDG PET
    Yanase, D
    Matsunari, I
    Yajima, K
    Chen, W
    Matsuda, H
    Yamada, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S363 - S363
  • [4] CT-based partial-volume compensation for PET/CT imaging.
    Hu, Z
    Kadrmas, DJ
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 40P - 40P
  • [5] Importance of partial-volume correction in brain PET studies
    Fazio, F
    Perani, D
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (11) : 1849 - 1850
  • [6] Effect of partial-volume correction on binding potential in high-resolution PET
    Funck, Thomas
    Paquette, Caroline
    Evans, Alan
    Thiel, Alexander
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [7] Effect of partial-volume correction on binding potential in high-resolution PET
    Funck, Thomas
    Paquette, Caroline
    Evans, Alan
    Thiel, Alexander
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [8] Partial-volume correction in dynamic PET-CT: effect on tumor kinetic parameter estimation and validation of simplified metrics
    Cysouw, M. C. F.
    Golla, S. V. S.
    Frings, V.
    Smit, E. F.
    Hoekstra, O. S.
    Kramer, G. M.
    Boellaard, R.
    EJNMMI RESEARCH, 2019, 9 (1)
  • [9] Partial-volume correction in dynamic PET-CT: effect on tumor kinetic parameter estimation and validation of simplified metrics
    M. C. F. Cysouw
    S. V. S. Golla
    V. Frings
    E. F. Smit
    O. S. Hoekstra
    G. M. Kramer
    R. Boellaard
    EJNMMI Research, 9
  • [10] PARTIAL-VOLUME PHENOMENON
    ZHU, XP
    CHECKLEY, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (04) : 842 - 842