Post-fire behavior of unconfined and steel tube confined rubberized concrete under axial compression

被引:37
作者
Bengar, Habib Akbarzadeh [1 ]
Shahmansouri, Amir Ali [1 ]
机构
[1] Univ Mazandaran, Dept Civil Engn, Babolsar, Iran
关键词
Steel-tube confined concrete; Axial compressive behavior; Tire rubber aggregate; Elevated temperatures; STUB COLUMNS; FIRE RESISTANCE; ELEVATED-TEMPERATURES; MECHANICAL-PROPERTIES; STRENGTH; PERFORMANCE; AGGREGATE; FIBER; UHPC; POLYPROPYLENE;
D O I
10.1016/j.istruc.2021.03.041
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Employing steel as a confining material for concrete has gradually been gaining popularity over the last decades. The literature demonstrates strength improvement, concrete stiffness, damage reduction, and delayed failure of steel-confined concrete after exposure to fire. Concrete columns confined by steel tubes, referred to as the steel tube-confined concrete (STCC) columns, have enhanced performance in terms of axial loading. Moreover, the presence of tire rubber aggregate in concrete mix has been shown to improve the plasticity and energy absorption, particularly in seismic areas. Even so, this method may decrease concrete strength in case of exposure to fire. In the present work, the compressive behavior of rubberized concretes confined by steel tubes was investigated where the replacement percentages of fine aggregates with rubber were 0, 7.5, and 15%. Thirty specimens were tested mechanically after thermal loading at 200, 400, 600, and 800 degrees C. The post-fire physicomechanical properties involving the failure modes, compressive stress-strain relationships, compressive strengths, elastic moduli, stiffness, and peak strain were experimentally investigated, together with visual observations. The experimental results demonstrate that an increase in the exposed temperature up to 400 degrees C does not have a significant effect on the compressive strength of rubberized STCC, whilst an increased temperature to 800 degrees C results in a significant decrease in the compression of the specimens. It is also indicated increasing the exposure temperature and crumb rubber replacement ratio leads to lead to an increase in the strain at peak stress of steel tube confined rubberized concrete.
引用
收藏
页码:731 / 745
页数:15
相关论文
共 84 条
  • [81] A unified interaction equation for strength and global stability of solid and hollow concrete-filled steel tube columns under room and elevated temperatures
    Yu, Min
    Xu, Haoming
    Ye, Jianqiao
    Chi, Yin
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 148 : 304 - 313
  • [82] A unified formula for calculating bending capacity of solid and hollow concrete-filled steel tubes under normal and elevated temperature
    Yu, Min
    Pei, Xiaoyan
    Xu, Lihua
    Ye, Jiangiao
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 141 : 216 - 225
  • [83] A unified method for calculating fire resistance of solid and hollow concrete-filled steel tube columns based on average temperature
    Yu, Min
    Zha, Xiaoxiong
    Ye, Jianqiao
    Wang, Baolin
    [J]. ENGINEERING STRUCTURES, 2014, 71 : 12 - 22
  • [84] Analysis and calculations of steel tube confined concrete (STCC) stub columns
    Yu, Qing
    Tao, Zhong
    Liu, Wei
    Chen, Zhi-Bo
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (01) : 53 - 64