Post-fire behavior of unconfined and steel tube confined rubberized concrete under axial compression

被引:37
作者
Bengar, Habib Akbarzadeh [1 ]
Shahmansouri, Amir Ali [1 ]
机构
[1] Univ Mazandaran, Dept Civil Engn, Babolsar, Iran
关键词
Steel-tube confined concrete; Axial compressive behavior; Tire rubber aggregate; Elevated temperatures; STUB COLUMNS; FIRE RESISTANCE; ELEVATED-TEMPERATURES; MECHANICAL-PROPERTIES; STRENGTH; PERFORMANCE; AGGREGATE; FIBER; UHPC; POLYPROPYLENE;
D O I
10.1016/j.istruc.2021.03.041
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Employing steel as a confining material for concrete has gradually been gaining popularity over the last decades. The literature demonstrates strength improvement, concrete stiffness, damage reduction, and delayed failure of steel-confined concrete after exposure to fire. Concrete columns confined by steel tubes, referred to as the steel tube-confined concrete (STCC) columns, have enhanced performance in terms of axial loading. Moreover, the presence of tire rubber aggregate in concrete mix has been shown to improve the plasticity and energy absorption, particularly in seismic areas. Even so, this method may decrease concrete strength in case of exposure to fire. In the present work, the compressive behavior of rubberized concretes confined by steel tubes was investigated where the replacement percentages of fine aggregates with rubber were 0, 7.5, and 15%. Thirty specimens were tested mechanically after thermal loading at 200, 400, 600, and 800 degrees C. The post-fire physicomechanical properties involving the failure modes, compressive stress-strain relationships, compressive strengths, elastic moduli, stiffness, and peak strain were experimentally investigated, together with visual observations. The experimental results demonstrate that an increase in the exposed temperature up to 400 degrees C does not have a significant effect on the compressive strength of rubberized STCC, whilst an increased temperature to 800 degrees C results in a significant decrease in the compression of the specimens. It is also indicated increasing the exposure temperature and crumb rubber replacement ratio leads to lead to an increase in the strain at peak stress of steel tube confined rubberized concrete.
引用
收藏
页码:731 / 745
页数:15
相关论文
共 84 条
  • [21] Experimental study on short rubberized concrete-filled steel tubes under cyclic loading
    Duarte, A. P. C.
    Silva, B. A.
    Silvestre, N.
    de Brito, J.
    Julio, E.
    Castro, J. M.
    [J]. COMPOSITE STRUCTURES, 2016, 136 : 394 - 404
  • [22] Effect of Fiber Reinforced Polymer Tubes Filled with Recycled Materials and Concrete on Structural Capacity of Pile Foundations
    Farhangi, Visar
    Karakouzian, Moses
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (05):
  • [23] Scrap-tyre-rubber replacement for aggregate and filler in concrete
    Ganjian, Eshmaiel
    Khorami, Morteza
    Maghsoudi, Ali Akbar
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (05) : 1828 - 1836
  • [24] Correlation of strength, rubber content, and water to cement ratio in rubberized concrete
    Ghaly, AM
    Cahill, JD
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 2005, 32 (06) : 1075 - 1081
  • [25] Failure mechanisms and cracking performance of T-shaped SCC beam-column connections at top floor: Test results and FE modeling
    Ghatte, Hamid Farrokh
    [J]. STRUCTURES, 2020, 28 : 1009 - 1018
  • [26] Environmental life cycle assessment of the manufacture of EPS granulates, lightweight concrete with EPS and high-density EPS boards
    Gomes, Raul
    Silvestre, Jose Dinis
    de Brito, Jorge
    [J]. JOURNAL OF BUILDING ENGINEERING, 2020, 28
  • [27] Compressive behaviour of concrete structures incorporating recycled concrete aggregates, rubber crumb and reinforced with steel fibre, subjected to elevated temperatures
    Guo, Yong-chang
    Zhang, Jian-hong
    Chen, Guang-ming
    Xie, Zhi-hong
    [J]. JOURNAL OF CLEANER PRODUCTION, 2014, 72 : 193 - 203
  • [28] Experimental behaviours of steel tube confined concrete (STCC) columns
    Han, LH
    Yao, GH
    Chen, ZB
    Yu, Q
    [J]. STEEL AND COMPOSITE STRUCTURES, 2005, 5 (06) : 459 - 484
  • [29] Experimental study and calculation of fire resistance of concrete-filled hollow steel columns
    Han, LH
    Zhao, XL
    Yang, YF
    Feng, JB
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2003, 129 (03) : 346 - 356
  • [30] Behavior of thin walled steel tube confined concrete stub columns subjected to axial local compression
    Han, Lin-Hai
    Liu, Wei
    Yang, You-Fu
    [J]. THIN-WALLED STRUCTURES, 2008, 46 (02) : 155 - 164